Skip to main content
v2026.11,986 entries · CC-BY 4.0

Direct Air Capture: How It Works, Types and Status

Direct air capture removes CO2 from ambient air. Compare liquid solvent and solid sorbent systems and read IEA 2022 cost and capacity figures correctly.

Written and maintained by CASRAI Editorial Board

Published

On this page

Direct air capture (DAC) is a form of carbon dioxide removal that pulls CO2 out of ambient air using chemical processes, then sends the concentrated CO2 to permanent underground storage or to use in products. The two main process families are liquid solvents and solid sorbents, and the US Department of Energy names current cost as the main drawback.

Definition and scope

The US Department of Energy (DOE) Office of Science describes direct air capture as a form of CO2 removal that takes CO2 from ambient, or still, air. The captured CO2 can then be stored permanently underground or converted into products. The defining feature is the source: the gas stream being treated is ordinary air, not the exhaust of a power plant or factory.

That source is also why the technology is expensive. DOE notes that CO2 makes up only a tiny share of the atmosphere, so moving enough air through the capture system takes a large amount of power. Storing or using the captured CO2 adds further cost on top of the capture step itself.

In this guide, ‘DAC’ means the capture step and, where a source says so, the storage or use step that follows it. When you read a DAC claim, check which of those steps the number covers. The checklist further down turns that into a repeatable routine.

How direct air capture works: liquid solvents and solid sorbents

DOE describes two broad approaches. Both pass air through a capture medium, then use a regeneration step to release a concentrated CO2 stream and make the medium reusable. The difference is the medium and what the regeneration step uses.

Step Liquid solvent systems Solid sorbent systems
Capture Air passes through chemicals that absorb CO2. Air passes over filters that chemically bind CO2.
Release and regeneration Heat and vacuum separate the CO2 and regenerate the chemicals for reuse. Heat and/or vacuum release a concentrated CO2 stream.
Air leaving the system Treated air returns to the atmosphere. The page describes the output as a concentrated CO2 stream.

Source: DOE Office of Science, ‘DOE Explains…Direct Air Capture’. The comparison above restates what that page says about each family; it does not rank them. Neither the DOE nor the IEA pages cited here name a winner, and the IEA states that cost depends on technology, energy prices, plant configuration and financing.

Why regeneration is where the energy goes

Both families need a regeneration step that uses heat, vacuum or both, and DOE ties the high cost of DAC to its power demand. Readers who work on the chemistry of solvent-based capture at power plants and industrial sources can see how absorption and regeneration cycles are engineered in the guide on amine scrubbing for CO2 capture. DOE does not say that DAC solvents are amines, so treat that page as the closest process analogue on this site, not as a description of any specific DAC product.

What happens to the captured CO2: storage versus use

DOE says the concentrated CO2 is either stored in geologic formations or used. Uses under exploration include building materials, chemicals and fuels. The IEA summary page for its 2022 report makes the same split: permanent storage keeps CO2 out of the atmosphere, and captured CO2 can also be used as a climate-neutral feedstock for products that need a carbon source.

The distinction matters for how you read results. The IEA’s 2022 survey counted 18 DAC facilities in Canada, Europe and the United States, and all but two sold their captured CO2 for use. Its largest operating plant, commissioned in Iceland in September 2021, captured about 4,000 tonnes of CO2 per year and stored it by mineralisation. So ‘a plant exists’ and ‘CO2 was permanently removed’ are not the same statement; the second needs the fate of the CO2.

Mineral storage and other removal pathways that act on rock or seawater are covered separately on this site, for example enhanced rock weathering and ocean alkalinity enhancement. They are different mechanisms from DAC, which captures CO2 from air with a dedicated capture system.

Direct air capture status: what the sources report

Two kinds of number circulate about DAC and they are easy to mix up: measured or planned plant capacity, and scenario projections for how much DAC the world might need. The IEA’s executive summary of Direct Air Capture 2022: A key technology for net zero (published 1 April 2022) contains both. All values below are as stated in that 2022 report; they are not current installed capacity.

  • Installed base, 2022. 18 facilities; global DAC capture of almost 0.01 MtCO2 per year; largest plant about 4,000 tCO2 per year.
  • Planned scale. The IEA expected the first large plant, capturing up to 1 MtCO2 per year, in the United States by the mid-2020s.
  • Scenario projection. In the IEA Net Zero Emissions by 2050 scenario, more than 85 Mt of CO2 is captured by DAC in 2030 and around 980 Mt in 2050, with around 350 Mt of air-captured CO2 used for synthetic fuels in 2050.
  • Cost. USD 125 to 335 per tonne of CO2 for a large-scale plant built today (2022). The IEA said cost could fall below USD 100 per tonne by 2030 in locations with high renewable energy potential, if deployment and innovation continue.
  • Public money. Governments committed almost USD 4 billion since the start of 2020, including USD 3.5 billion for four US DAC hubs and a USD 115 million DAC Prize. Leading DAC companies raised around USD 125 million in private capital over the same period.

On the US programme side, DOE’s regional DAC hubs page says DOE will develop four domestic hubs to demonstrate DAC at commercial scale, each with the potential to capture at least 1 million metric tons of CO2 per year from the atmosphere, with captured CO2 stored permanently in geologic formations or converted into new products. DOE’s Carbon Negative Shot sets a cost goal of capturing CO2 from the atmosphere at 1 billion ton scales for less than USD 100 per net metric ton of CO2-equivalent. The data table below sets these figures side by side with their units and sources.

Worked example: putting the 2022 numbers on one scale

Mixing tonnes and megatonnes is the most common slip. One megatonne (Mt) is 1,000,000 tonnes. Using only the IEA and DOE figures above:

  1. The largest 2022 plant, 4,000 tCO2 per year, is 0.004 MtCO2 per year, which is 0.4% of one 1 MtCO2 per year plant.
  2. One DOE hub with the potential for at least 1 million tonnes per year equals 1 MtCO2 per year, about 100 times the almost 0.01 MtCO2 per year of global DAC capture the IEA reported for 2022.
  3. The IEA scenario value of more than 85 Mt in 2030 is about 8,500 times that 2022 figure; the 980 Mt value for 2050 is about 98,000 times it.
  4. Applying the IEA’s USD 125 to 335 per tonne range to 1 MtCO2 per year gives a capture cost of roughly USD 125 million to USD 335 million per year for that plant, before any extra cost for transport and storage, which the IEA range is not stated to include.

This is arithmetic on the sources’ own figures, offered as an illustration of scale. It is not a forecast, and the ratios shift if you use a newer capacity number than the 2022 one.

A checklist for reading a DAC claim

The sources above support a short set of questions that separate comparable claims from incomparable ones. Each question is tied to something the sources state.

Question to ask Why it matters, from the sources
Is the CO2 stored or used? DOE and the IEA both describe storage and use as separate fates, and the IEA found that all but two of 18 plants sold their CO2 for use.
Does the cost cover capture only, or capture plus storage or use? DOE says storing or using the CO2 adds cost beyond capture.
Which year and cost basis? The IEA’s USD 125 to 335 per tonne is for a large plant built in 2022 terms; its under-USD 100 figure is a possibility for 2030 in high-renewable locations.
Per tonne of CO2 or per net tonne of CO2-equivalent? The IEA quotes per tonne of CO2; the DOE Carbon Negative Shot target is per net metric ton of CO2-equivalent.
Capacity, capture or scenario? Plant capacity in tCO2 per year, achieved capture, and Mt scenario values answer different questions.
Which energy source powers the process? DOE ties DAC cost to power demand; the IEA says cost depends on energy prices.

Where DAC matters for labs and research programmes

DOE says support for DAC research and demonstration comes through several of its offices: Fossil Energy and Carbon Management, Clean Energy Demonstrations, ARPA-E, and the Office of Science’s Basic Energy Sciences and Biological and Environmental Research programmes. For a research team, that means DAC work is funded and described across basic science (sorbent and solvent chemistry), demonstration engineering and environmental research, and a funding call or paper may use the vocabulary of any of those.

For a chemical or process engineering group, the sources point to a few measurable quantities that recur: how much CO2 a capture medium takes up from air, what heat or vacuum the release step needs, and how much power the whole system draws per tonne captured. The DOE and IEA pages cited here give no benchmark values for these, so compare any figures you meet against the paper or report that reports them, with its test conditions, rather than against a number from a different system.

Reporting questions follow from this. A project that states a removal figure should say which fate (storage or use) applies, which year’s cost it assumes, and whether the quantity is capture or net removal.

Common misunderstandings about direct air capture

DAC is the same as capturing CO2 at a smokestack

It is not. DOE defines DAC by its source, ambient air, which is why the tiny share of CO2 in air drives the power demand. Capture at a power plant or industrial site treats a gas stream that already carries a much higher CO2 share; that is a different engineering problem, and DAC claims should not borrow its cost figures.

Captured CO2 is always removed from the atmosphere for good

Only if it is stored permanently. DOE says storage can be permanent underground, while uses such as fuels, chemicals and building materials are still being explored. The IEA’s 2022 survey found most plants selling their CO2 for use, so a plant count alone does not say how much CO2 was durably removed.

The IEA’s 2050 figure describes what is installed or planned

No. The 980 Mt value is a result in the IEA Net Zero Emissions by 2050 scenario. The installed base the IEA reported for 2022 was almost 0.01 MtCO2 per year.

DAC has one known cost

It does not. The IEA gives a range of USD 125 to 335 per tonne for a large plant in its 2022 analysis and says cost depends on technology, energy prices, plant configuration and financing. DOE’s under-USD 100 figure is a programme target, not a measured cost.

Sources

Data: Direct air capture figures: 2022 IEA status, scenario values and DOE targets

Original compilation of the quantitative statements about direct air capture in the IEA's Direct Air Capture 2022 executive summary and in two US Department of Energy pages. Each row keeps the source's own wording as the basis column so that installed figures, scenario projections and programme targets are not confused. Values are as stated in those sources; the 16-facility row is derived by subtracting the IEA's 'all but two' from 18.

Period covered: 2021 to 2050 (2022 report). Coverage: Canada, Europe, United States (2022 plant survey); global (scenario).

Direct air capture figures: 2022 IEA status, scenario values and DOE targets
MeasureValueUnitBasis and caveatSource
DAC facilities in operation, 202218facilitiesIEA survey of Canada, Europe and the US; all but two sold captured CO2 for useIEA 2022
Facilities selling captured CO2 for use, 202216facilities18 facilities minus the two the IEA says did not sell CO2 for useIEA 2022
Largest operating plant, Iceland (Sept 2021)4000tCO2 per yearStorage by mineralisationIEA 2022
Global DAC capture, 2022 (almost)0.01MtCO2 per yearIEA states 'almost 0.01 MtCO2'IEA 2022
IEA Net Zero Emissions by 2050 scenario, 2030 (more than)85Mt CO2 capturedScenario projection, not installed capacityIEA 2022
IEA Net Zero Emissions by 2050 scenario, 2050 (around)980Mt CO2 capturedScenario projection, not installed capacityIEA 2022
Cost, large plant built today (low end)125USD per tCO2IEA 2022 estimate; depends on technology, energy prices, configuration, financingIEA 2022
Cost, large plant built today (high end)335USD per tCO2IEA 2022 estimate; same caveatsIEA 2022
Potential capture per DOE regional DAC hub (at least)1000000tonnes CO2 per yearDOE hub programme goal; four hubsDOE hubs page
DOE Carbon Negative Shot cost target (less than)100USD per net tonne CO2-equivalentTarget at 1 billion ton scale; not a measured costDOE Office of Science

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Direct Air Capture: How It Works, Types and Status

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →