Written and maintained by CASRAI Editorial Board
Published
On this page
DNase-seq is a sequencing method that maps open chromatin. It uses the enzyme DNase I, which preferentially cuts nucleosome-depleted DNA, then sequences the cut sites so that DNase I hypersensitive sites (DHS) can be located across the genome. DHS mark promoters, enhancers, silencers, insulators and locus control regions. It is not DNA-seq (genome sequencing) and not RNA-seq (transcript measurement).
Definition and scope
The Cold Spring Harbor Protocols description by Song and Crawford (2010) defines the assay as a technique that uses DNase I to selectively digest nucleosome-depleted DNA, so the sites that are cut most often are the open, regulatory regions of the genome. The digested ends are captured, turned into short tags and read on a high-throughput sequencer. The result is a genome-wide map of where chromatin is accessible in the cell type you started from.
Because the name is so close to other assays, it helps to separate five things that searches often mix together:
- DNase-seq: sequencing of DNase I cut sites to find hypersensitive (open) regions. The subject of this page.
- DNase-chip: the earlier microarray readout of the same biology. The protocol paper puts its resolution at about 300 to 700 bases, against single base-pair resolution of digestion sites for DNase-seq.
- DNA-seq: sequencing of genomic DNA itself (variants, assemblies). It says nothing about accessibility.
- RNA-seq: sequencing of RNA to measure expression. See the RNA-seq workflow guide.
- Footprinting analysis: a computational use of deeply sequenced DNase-seq data to find short protected stretches where a bound protein blocked cleavage.
The same source is explicit about scope. DNase-seq can only be applied genome-wide unless an array capture method is added, the analysis software was described as still relatively immature, and the assay does not directly reveal the biological function of the elements it finds. Follow-up work such as ChIP-based assays or functional tests is needed to say what a hypersensitive site does.
How DNase-seq is used in practice
In the published protocol, the starting material is a single-cell suspension: the standard protocol begins with 50 million human or mammalian cells, and its troubleshooting notes say it has also worked with fewer cells when volumes and DNase amounts are scaled down empirically. The digestion is then calibrated: the protocol tests a range of DNase I concentrations and picks the digest that gives the expected size distribution on a pulsed-field gel. After digestion the cut ends are blunted, tagged with a biotinylated adapter, trimmed to short tags of roughly 20 bp, amplified and sequenced on an Illumina-type instrument.
Two practical lessons recur across the sources.
Digestion strength is a variable you tune, not a constant
The protocol paper notes that heavier digestion lowers signal to noise, so DNase I has to be titrated for each cell type. The single-cell protocol paper (Cooper et al., Nature Protocols, 2017) reports the same thing from the other side: its highest DNase I concentrations over-digested chromatin and showed a depletion of reads close to transcription start sites, and excess enzyme produced more small fragments from non-hypersensitive regions, raising background.
Input quality changes what the data mean
Cooper et al. require cultured-cell viability above 95% and exclude dead and apoptotic cells by flow sorting. They also describe a no-DNase control: visible DNA in the 150 to 350 bp range in that control suggests unacceptably high background. Those are specific checks you can write into a study plan rather than discover from a poor library.
Types and related methods
The data table below puts DNase-seq next to its closest relatives using only figures the source papers state. It is a planning aid, not a ranking: the papers describe different generations of each method, and a number such as a cell count is the value the authors give for their own protocol.
For the neighbouring accessibility and binding assays, see ATAC-seq, CUT&RUN and chromatin immunoprecipitation (ChIP). ATAC-seq reads open chromatin with a transposase instead of a nuclease; ChIP and CUT&RUN map where a specific protein or histone mark sits.
Footprinting: what deeper sequencing buys
A footprint is a protected region, a short stretch where a bound protein blocked DNase I cleavage. Barozzi, Bora and Morelli (Frontiers in Genetics, 2014) compared footprint-calling strategies, Wellington and DNaseR, with the footprint occupancy score used in the ENCODE project, against 17 ChIP-seq binding patterns for 11 transcription factors in K562 cells. They report that footprint counts level off only at very high depth, above roughly 400 million aligned reads, that Wellington had the highest AUC across factors, and that for some factors such as CTCF, simply asking whether a motif lies inside a hypersensitive site predicted binding as well as or better than the ENCODE footprints. For a lab, that means footprinting is a sequencing-budget decision, and plain DHS calling may answer many questions at far lower depth.
Where it matters for labs and core facilities
The planning questions below come straight from the sources above. They are the reason to read the protocol papers before booking sequencing.
- Cell number. Conventional DNase-seq was designed around tens of millions of cells (50 million in the standard protocol); Cooper et al. state that the original method requires millions of cells and design scDNase-seq for fewer than 1,000 cells. The original ATAC-seq method was optimized for exactly 50,000 cells, and its sensitivity and specificity drop considerably at 500 or 5,000 cells.
- Cell type. The digestion is scaled and titrated per cell type, so a protocol that worked on one line is a starting point, not a specification.
- Controls. Cooper et al. use a no-DNase control. Plan for it before the experiment.
- Sequencing depth. For single-cell libraries, Cooper et al. sequence to more than 30 million reads to obtain over 300,000 unique reads, with estimated library complexity above 200,000 unique fragments and at least fivefold enrichment at transcription start sites. For footprinting, the depth discussed above is far higher.
- Follow-up. Budget for orthogonal assays, because a hypersensitive site alone does not state function.
- Reference data. Public DNase-seq data from the ENCODE consortium are a common comparison set when you want to check your own peaks against other cell types.
Quality checks you can write into a study plan
The single-cell protocol paper is unusually explicit about pass/fail checks. The table collects the ones it states for scDNase-seq libraries, with what each is meant to catch. They are the authors’ thresholds for that protocol, so treat them as a model for how to define acceptance criteria, not as universal cut-offs for every DNase-seq design.
| Check | Threshold or sign stated | What it guards against |
|---|---|---|
| Cell viability (cultured cells) | Greater than 95%; dead and apoptotic cells excluded by FACS | Nucleosomal background from dying cells |
| Digestion strength | Highest concentrations (0.5 to 1 U/μl in that protocol) over-digest chromatin | Loss of reads near transcription start sites; extra small fragments from non-DHS regions |
| No-DNase control | Visible DNA at 150 to 350 bp suggests unacceptably high background | Background that mimics signal |
| Library size selection | About 150 to 300 bp; gel cut at 160 to 260 bp | Carrying over fragments outside the useful range |
| Sequencing yield | More than 30 million reads to obtain over 300,000 unique reads | Under-sequenced, low-complexity libraries |
| Library complexity | Estimated above 200,000 unique fragments | Over-amplification of too little starting material |
| TSS enrichment | At least fivefold over background | Libraries with no real open-chromatin signal |
Reading the table in context
Two of these checks, the no-DNase control and TSS enrichment, are worth adopting even if you use a different protocol, because they test the assay’s central claim: that cuts concentrate at accessible sites rather than everywhere. The first tells you how much of the signal is background. The second tells you whether the reads pile up where open chromatin is expected, at promoters. A library that passes size selection but fails both is a library of fragments, not a map.
The protocol paper by Song and Crawford adds a reminder that the earlier array readout, DNase-chip, trades resolution for convenience: its 300 to 700 base resolution is a consequence of the shearing step, which is why sequencing replaced it for work that needs the exact position of a cut.
Common misunderstandings
- “DNase-seq is DNA-seq.” No. DNA-seq reads the sequence of genomic DNA; DNase-seq uses the pattern of enzyme cuts to read accessibility.
- “A hypersensitive site is a functional enhancer.” The protocol authors state that the assay does not directly disclose biological function, so a DHS is a candidate that needs validation.
- “More enzyme gives a better map.” The opposite: over-digestion lowers signal to noise and raises background.
- “Footprints come free with any DNase-seq run.” They need very deep sequencing, and for some factors the DHS motif alone predicts binding about as well.
Frequently asked questions
What is RNA-seq data?
RNA-seq data are sequencing reads from RNA molecules, used to measure which genes are expressed and at what level. It is a different assay from DNase-seq, which reads where DNase I cuts the genome, not which transcripts are present. The RNA-seq guide covers that workflow.
What is a DNase hypersensitivity assay?
It is an assay that uses DNase I to cut chromatin and finds the regions that are cut most readily, the DNase I hypersensitive sites. Those sites are open, nucleosome-depleted DNA, and they mark promoters, enhancers, silencers, insulators and locus control regions. DNase-seq is the sequencing-based version; DNase-chip is the older array-based one.
Where can I find the reference genome?
DNase-seq reads are aligned to the reference assembly for the species you sampled. NCBI RefSeq describes its genomes as copies of selected assembled genomes available in GenBank, and makes them available through BLAST, Entrez and the NCBI FTP site, with information also in NCBI’s Assembly and Genomes resources. Record the exact assembly version you align to, so peaks can be compared with public data.
How much does an NGS test cost?
No single figure applies to DNase-seq, because cost depends on the instrument, depth and what a quote includes. NHGRI’s cost-per-genome page gives retrospective whole-genome figures (just above $4,000 for a draft human genome in mid-2015, below $1,500 by late 2015) and warns that cost is not price, that vendors differ in what they include, and that its accounting does not typically include quality control, alignment to a reference, assembly, variant calling or annotation. Those exclusions are why a sequencing quote and a finished DNase-seq analysis are not the same number. Ask a core facility for a quote at the depth your design needs.
Sources
- Song L, Crawford GE. DNase-seq: a high-resolution technique for mapping active gene regulatory elements across the genome from mammalian cells. Cold Spring Harbor Protocols, 2010. PMC3627383 (read 2026-11-20).
- Cooper J, Ding Y, Song J, Zhao K. Genome-wide mapping of DNase I hypersensitive sites in rare cell populations using single-cell DNase sequencing. Nature Protocols, 2017. PMC11005227 (read 2026-11-20).
- Barozzi I, Bora P, Morelli MJ. Comparative evaluation of DNase-seq footprint identification strategies. Frontiers in Genetics, 2014. PMC4133688 (read 2026-11-20).
- NHGRI. The cost of sequencing a human genome. genome.gov (page updated 2021-11-01; read 2026-11-20).
- NCBI. RefSeq: about. ncbi.nlm.nih.gov/refseq/about (read 2026-11-20).
Data: DNase-seq and related chromatin-accessibility methods: stated inputs, readout and limits
Compiled by the CASRAI team from three peer-reviewed protocol and method papers on DNase-seq, DNase-chip, single-cell DNase-seq and ATAC-seq. Each cell repeats a figure or statement the cited paper makes about its own protocol; the methods were not run side by side.
Period covered: 2010/2017.
| Method | Cell input stated by the source | Readout and resolution stated | Limit stated | Source |
|---|---|---|---|---|
| DNase-seq (standard protocol) | 50 million human or mammalian cells; worked with fewer when scaled empirically | Single base-pair resolution of digestion sites | Genome-wide only unless array capture is used; software relatively immature; does not directly disclose function | Song and Crawford 2010 |
| DNase-chip | Not stated in the source | Resolution about 300 to 700 bases | Lower resolution than DNase-seq | Song and Crawford 2010 |
| scDNase-seq | Single cells or fewer than 1,000 primary cells | DHS mapping from rare populations; at least fivefold TSS enrichment expected | Over-digestion depletes reads near TSS and raises background; viability above 95% for cultured cells | Cooper et al. 2017 |
| ATAC-seq (original method) | Optimized for exactly 50,000 cells | Comparison method for accessible chromatin (no resolution figure stated) | Sensitivity and specificity drop considerably at 500 or 5,000 cells | Cooper et al. 2017 |
| DNase-seq footprinting analysis | Not stated in the source | Protected regions at base-pair scale; 17 ChIP-seq patterns for 11 factors in K562 used for validation | Counts level off only above roughly 400 million aligned reads; motif within a DHS predicts some factors (e.g. CTCF) as well | Barozzi et al. 2014 |
Sources
- Song and Crawford 2010, DNase-seq (Cold Spring Harbor Protocols) (accessed 2026-11-20)
- Cooper et al. 2017, scDNase-seq (Nature Protocols) (accessed 2026-11-20)
- Barozzi, Bora, Morelli 2014, DNase-seq footprint strategies (Frontiers in Genetics) (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







