Skip to main content
v2026.11,986 entries · CC-BY 4.0

EDTA SDS: Hazards, PPE and Manufacturer Sheets

Compare EDTA safety data sheets by chemical form, with manufacturer PDFs, hazard classifications, PPE, storage and waste distinctions.

Written and maintained by CASRAI Editorial Board

Published

On this page

An EDTA SDS must match the chemical form and the supplier’s product: free acid, disodium salt, tetrasodium salt and prepared solutions can have different hazard classifications. The manufacturer sheets linked here compare those differences, including inhalation warnings, eye hazards, protective equipment, storage incompatibilities and disposal requirements for laboratory staff.

Short answer

Start with the product identifier rather than the abbreviation EDTA. Fisher’s free-acid SDS for AC11843 identifies CAS 60-00-4; its A15161 disodium dihydrate sheet identifies CAS 6381-92-6; A17385 tetrasodium hydrate identifies CAS 194491-31-1. A finished solution has its own product identifier and composition. These are separate documents, even when a laboratory inventory shortens every name to “EDTA.”

The comparison data below preserves the supplier, form, document revision and classification together. It is a reference for finding the relevant sheet, not a replacement label. For example, Fisher’s SS412-1 standard solution has no required hazard label elements under its US SDS, while the solid A15161 document carries inhalation and repeated-exposure warnings. Applying the solution’s classification to a bottle of powder would discard that distinction.

Definition and scope

EDTA is ethylenediaminetetraacetic acid, also called edetic acid. This guide concerns laboratory chemical safety documents for the acid, selected sodium salts and a manufactured aqueous standard. It does not cover treatment uses, blood-collection technique or preparation recipes. Formula weights and hydration states have a separate role in identifying reagents; the EDTA molecular-weight guide explains those distinctions.

OSHA’s Safety Data Sheets brief describes the standardized 16-section SDS format and its earlier name, material safety data sheet or MSDS. Section 1 identifies the product and supplier; section 3 identifies composition. The document also communicates hazards, controls, storage conditions and emergency information. An old search result headed “EDTA MSDS” therefore still needs an identity and revision check before it becomes the document associated with a current container.

Hazard classification belongs to the identified substance or mixture in that document. The examples here include US, Australian and bilingual supplier sheets. Their classifications are reported separately, rather than combined into a new classification. Geographic scope and revision matter alongside chemical identity.

How an EDTA SDS is used in practice

The SDS connects product identification to the information needed for a workplace assessment. Under OSHA’s format, section 2 supplies the classification and label elements, section 7 covers handling and storage, section 8 covers exposure controls and personal protection, and section 10 covers stability and reactivity. Sections 6 and 13 address releases and disposal; section 16 records preparation or revision information. CASRAI’s guide to reading the 16 SDS sections explains the wider format.

An SDS review can use the following document checklist. These are checks on information, rather than instructions for carrying out a chemical operation:

  • Identity: supplier, catalogue number, chemical form and CAS information agree with the container.
  • Mixture: section 3 describes the supplied formulation, rather than an assumed powder or solution.
  • Label: signal word, hazard categories and precautionary statements come from the same document.
  • Controls: sections 7, 8 and 10 are considered together; a short hazard label does not contain all storage or protective-equipment information.
  • Document control: revision information remains attached to the product record, alongside the supplier’s emergency contact details.

This checklist is an editorial synthesis of OSHA’s section descriptions. It does not assign a risk score or establish that a particular task has adequate controls.

The data table below compares named manufacturer documents for free-acid powder, disodium dihydrate, tetrasodium hydrate and a prepared disodium standard. It also includes a second supplier’s acid sheet to show why matching the CAS number alone does not settle every label question. Read each row with its product and revision; the table does not rank the products or claim interchangeability.

EDTA hazards: why the warnings differ

The Thermo Fisher A15161 SDS lists acute inhalation toxicity category 4 and repeated-exposure specific target-organ toxicity category 2. Its codes H332 and H373 identify harmful inhalation and potential organ damage from prolonged or repeated exposure. In contrast, the A17385 tetrasodium hydrate SDS adds oral toxicity category 4 and serious eye damage category 1, with the signal word Danger. Its H318 and combined H302 + H332 identify serious eye damage and harmful ingestion or inhalation.

There is also a same-form difference. The Fisher US free-acid SDS includes inhalation toxicity, eye irritation and repeated-exposure toxicity. The Carl Roth CN06 Australian free-acid SDS lists eye irritation category 2 in section 2. Both identify CAS 60-00-4. This comparison establishes a difference between the documents; it does not establish why they differ or authorize substituting the shorter classification for another supplier’s label.

Where EDTA SDS details matter for labs and supply decisions

PPE and airborne dust

The A17385 sheet places engineering controls at the source of exposure: enclosure or isolation, process changes and suitable ventilation where possible. Its section 8 specifies goggles, protective gloves and clothing, with glove suitability assessed against the task and supplier information on permeation and breakthrough. A list of possible glove materials is not a universal breakthrough-time guarantee.

Fisher’s free-acid sheet likewise calls for ventilation, eye protection, gloves and protective clothing, and places eyewash stations and safety showers near the workstation. The associated safety-goggles guide explains the equipment category. The product SDS and workplace assessment determine the applicable protection; the product name alone does not specify a complete ensemble.

Precautionary codes help locate the label’s priorities. A15161 includes P260 for avoiding inhalation and P271 for ventilation. A17385 includes P261 for inhalation avoidance and P280 for protective clothing, gloves and eye/face protection. These references summarize the prevention statements; the complete response statements remain in the linked SDS. They are not a substitute for the product’s emergency information.

Exposure limits and NIOSH guidance

Fisher’s free-acid SDS reports that its product contains no hazardous materials with occupational exposure limits established by the region-specific regulatory bodies. That statement is not an exposure limit of zero, an unlimited permissible exposure, or a finding that dust is harmless.

NIOSH’s occupational exposure-banding guidance addresses chemicals that lack occupational exposure limits. It describes five bands, A–E, based on toxicological potency and adverse effects, and three assessment tiers whose suitability depends on the available information and the assessor’s expertise. An exposure band supplies a concentration range; it still requires decisions about measuring exposure and implementing controls. This guidance does not itself assign EDTA a band. Neither an EDTA-specific OSHA PEL nor a NIOSH REL is inferred here from a generic dust value or a missing entry.

Storage class and chemical incompatibilities

Sigma-Aldrich’s E5134 safety listing assigns the disodium dihydrate product storage class 11, combustible solids. It also lists H332/H373 and the exclamation-mark and health-hazard pictograms. That storage class is a product-specific storage descriptor; it is not an instruction to file every EDTA formulation in the same group.

The individual sheets give more useful segregation detail. A15161 identifies strong oxidizers as incompatible. Fisher’s free-acid sheet lists strong oxidizers, strong bases, metals and copper. A17385 lists strong oxidizers, strong acids and metals, and specifically excludes aluminum storage containers. Those different lists make a single inventory rule such as “EDTA goes with acids” too crude. The chemical-storage compatibility guide explains segregation principles; the product’s sections 7 and 10 supply the specific compatibility information.

Storage temperature is equally document-specific. Roth’s CN06 sheet recommends 15–25°C, dry storage, closed containers and ventilation. A15161 instead describes cool, dry, ventilated storage without assigning that numerical range. A temperature from one product should therefore remain attached to that product rather than become an unsupported specification for the whole chemical family.

Fire, releases and disposal

The ILO/WHO International Chemical Safety Card 0886, dated August 2008, identifies free-acid EDTA as combustible and describes a dust-explosion possibility when dispersed particles mix with air. It also describes decomposition on heating and separation from strong oxidizers and metals. This is background for that chemical form, not a current manufacturer label for every salt or solution.

The card’s emphasis on airborne particles explains why avoiding dust belongs in a solid-reagent assessment even when the inventory is chiefly concerned with liquid chemicals. Its free-acid identity and older date also make it a supporting reference alongside the supplier document, rather than a replacement for the supplied product’s SDS.

Roth’s CN06 sheet addresses dust control during release management, keeping material away from drains and retaining contaminated wash water. Its handling section also addresses dust deposits and occupational hygiene. These details belong in release planning alongside the local response arrangements, not just in the hazard-code field of an inventory.

For disposal, A15161 includes P501 and section 13 excludes discharge into drains. The Fisher SS412-1 solution SDS separately places responsibility on the waste generator to determine the discarded chemical’s classification under applicable local, regional and national rules. Thus a prepared solution’s nonhazardous workplace classification does not by itself establish a disposal route. Transport status, GHS workplace classification and waste classification answer different questions.

Common misunderstandings

“All EDTA has the same SDS.” The manufacturer documents distinguish acid, salts, hydration states and mixtures. Product identity must remain visible when hazard information is transferred to an inventory or assessment. The shared abbreviation cannot carry those distinctions by itself.

“No required label means no precautions.” Fisher SS412-1 is not considered hazardous under its US Hazard Communication Standard classification, yet its section 8 still specifies eye protection and protective gloves/clothing. Its handling and storage information also remains part of the document. Classification and the full set of workplace precautions are related, but they are not identical fields.

“Not regulated for transport means harmless.” A15161 reports unregulated status for the listed transport modes while retaining its inhalation warnings. A shipping determination does not erase the hazards in section 2, and it does not decide the classification of a discarded laboratory mixture.

“A generic exposure number completes the assessment.” NIOSH’s banding framework requires toxicological information, an appropriate assessment tier and subsequent measurement/control decisions. A laboratory cannot derive an EDTA-specific legal or recommended limit merely from the existence of that framework.

Sources

Data: EDTA manufacturer SDS identity and hazard comparison

Original comparison of five named manufacturer SDS documents for EDTA acid, sodium salts and a finished standard solution. Product identifiers, CAS identity, revisions and section 2 classifications remain separate; regional documents do not establish one universal EDTA classification.

EDTA manufacturer SDS identity and hazard comparison
Manufacturer and productChemical identity / CASDocument scopeSDS revisionSignal wordSection 2 classification
Fisher AC11843Free acid; 60-00-4US OSHA HCS2025-12-18WarningAcute inhalation toxicity 4; eye irritation 2; repeated-exposure target-organ toxicity 2 (respiratory system)
Carl Roth CN06Free acid; 60-00-4Australian SDS2024-09-18WarningEye irritation 2 (H319)
Thermo Fisher A15161Disodium dihydrate; 6381-92-6Bilingual supplier SDS2026-07-24WarningAcute inhalation toxicity 4; repeated-exposure target-organ toxicity 2 (H332, H373)
Thermo Fisher A17385Tetrasodium hydrate; 194491-31-1Bilingual supplier SDS2026-07-24DangerAcute oral toxicity 4; acute inhalation toxicity 4; serious eye damage 1 (H302 + H332, H318)
Fisher SS412-10.1 M aqueous disodium EDTA standard; dihydrate ingredient 6381-92-6US OSHA HCS2025-12-18None requiredNot considered hazardous under the US OSHA Hazard Communication Standard; no label elements required

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about EDTA SDS: Hazards, PPE and Manufacturer Sheets

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →