Skip to main content
v2026.11,986 entries · CC-BY 4.0

Waters Empower Software: Workflow, Methods and Results

How Waters Empower chromatography data software is organised and the documented path from login to calibration curve and printed report.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Waters Empower is a chromatography data software system: it controls chromatographic instruments, acquires the detector data, processes it into peak results and stores it with its methods and audit information in one project. The Empower 3 Getting Started Guide defines it as “a software system for single or multi-system computers, linked to a set of chromatographic instruments, that performs acquisition, processing, and management of chromatographic information.” This guide walks through how the software is organised, the documented menu path from login to a printed report, and how to read the calibration output, using the Empower 3 Getting Started Guide (part 715005480 Rev A, 15 August 2017) as the documented edition.

What Empower is used for in research

Empower runs on Windows, is multitasking (you can watch a live run while you process earlier data), and handles liquid chromatography (LC), gas chromatography (GC) and ion chromatography (IC) data in its base version, including photodiode array (PDA) and mass spectrometry (MS) detector data. Optional modules named in the guide include Dissolution, System Suitability, GPC, GPCV, Light Scattering, Chemical Structures and a Toolkit. It acquires data from Waters instruments and from third-party instruments.

In a research or analytical laboratory the practical uses are the ones the guide describes: injecting single samples or running a set of standards, unknowns and controls under one predefined set of conditions, integrating peaks, calibrating standards, quantitating unknowns and producing reports. Because methods, results, raw data and sign-off information are kept together, the same software also holds the record that a reviewer or auditor later inspects. For what a chromatography data system must log, see the guide to chromatography data system audit trails; for validating the installed system, see IQ/OQ/PQ.

How Empower organises work: projects, methods and sets

Understanding the object model removes most of the confusion new users have, because every screen in the software is a view of one of these objects.

  • Project. The basic organisational unit: a user-defined collection of methods, results, peaks, custom fields and raw data, which may also include audit trail and sign-off information. Everything except raw data lives in a reserved area of tablespace in the Empower database; raw data is stored in a separate directory.
  • Method. A set of instructions for one task (control the instrument, acquire, process, report or export). Methods exist independently and are combined into a method set.
  • Method set. A group of methods applied together. For a single injection you must, at a minimum, create a method set containing an instrument method so that data can be acquired.
  • Sample set. The bound collection of raw data (the injections and all channels) produced when a sample set method is run.
  • Result set. The bound collection of results produced when a sample set is processed with a processing method.

The data table below lists the seven method types in the guide’s Table 1-1 and what each one specifies. Two of them matter most for quantitation: the processing method defines integration (Traditional integration, which finds peak start and end for each peak, or ApexTrack integration, which determines the peak apex), calibration and component identification, and the sample set method defines which samples run, in which order, how many injections, the injection volume and the run time.

Install or access Empower

Installation is documented by Waters in the separate Empower 3 Installation, Configuration, and Upgrade Guide, and the Getting Started Guide notes that the chromatographic system and project are usually created by a Waters Field Service Engineer. For a researcher the working prerequisites are therefore an account on an existing installation, access to a project, and instruments that already appear as a configured system in the Systems view of Configuration Manager. Licensing and pricing are agreed with Waters or its authorised sellers and are not covered here.

At login Empower offers three interfaces, and an administrator decides which are allowed (Login dialog, Advanced, Allowed User Interfaces):

  • QuickStart, the simplified interface used in the guide’s tutorial steps.
  • Pro, with full control, intended for administrators and advanced users.
  • Walk-Up, for submitting routine samples without deep chromatography knowledge.

Step-by-step: from login to a printed report

The steps below follow the Empower 3 Getting Started Guide, which uses the QuickStart interface. Menu wording can differ between releases and with the privileges an administrator grants you.

1. Log in and open a project

  1. Double-click the Empower icon.
  2. In the Login dialog enter your user name and password, and select the database (workgroup or enterprise).
  3. Click Advanced and choose the QuickStart interface.
  4. In the Select Project and System dialog choose your project and system, then click OK. QuickStart opens on Browse Project.

2. Build the methods

To create a processing method, take an injection with a 2D channel into Review, then choose File, New, Processing Method. Select the type (typically LC; PDA or GPC depending on the data), choose the integration algorithm, pick a wizard option, decide whether to use a cross-channel internal standard (the guide points to the F1 help for this), click OK and follow the wizard. Add the processing method, with the instrument method, to a method set.

3. Acquire data

  1. In the navigation bar choose Run Samples.
  2. Choose a Run Mode from the list: Run Only (collect raw data only), Run and Process (collect and then process) or Run and Report.
  3. For a single injection click Inject, which opens the Specify Single Inject Parameters dialog. For several samples use the Samples tab and the Sample Set Wizard, which walks through the standards location, calibration options, standard bracket, samples, identification pages and runtime options.

4. Process the data

  1. In Browse Project, right-click the sample set and choose Process, which opens the Background Processing and Reporting dialog.
  2. Choose whether to use the acquisition method set, a specified method set or a specified processing method. Multi-channel, 3D or derived-channel data require a method set.
  3. Choose Calibrate and Quantitate under How, optionally with Clear Calibration, and start processing.

5. Review, report and back up

  1. On the Result Sets tab (use Update in the toolbar to refresh), right-click the result set, choose Review, then Yes to open the Review Data main window.
  2. To report, go to the Results tab, select the result, choose View Data, and in the Open Report Method dialog select “Use the following Report Method” and Default Individual Report. Preview, then print.
  3. To back up, choose Manage, Backup Current Project (requires the Backup Projects privilege) and follow the Backup Project Wizard. Waters recommends backing up to a destination external to the Empower hard drive.

Output and how to read it

Processing produces a result set. Right-click it and choose View As, then Results to see the peak table or Calibration Curves to see the fit. In Review Data, the Peaks tab lists the integrated peaks, and the Calibration Curve tool shows the line equation, R2, a plot of Amount (x) against Area (y) and a table of the calibration points.

For an external standard calculation, Empower computes the amount from the peak area using the calibration curve, divides by the sample weight and multiplies by the dilution; both default to 1. A low R2 or a point sitting far from the line is the first thing to inspect before trusting quantitated unknowns. Check also whether the integration drew the baseline where you expect before changing the calibration model.

The Process column of a sample set controls what happens to each row after injection, as documented by Waters in its knowledge base for Empower 3:

  • Normal: follow the run mode set when the run started.
  • Don’t Process or Report: acquire only.
  • Don’t Report: process but do not report.
  • Ignore Faults and Ignore Stability: the latter disables the Suitability tab settings of the processing method.

Troubleshooting common situations

  • The instrument is not available for a run. Instruments must appear as a configured system in the Systems view of Configuration Manager; confirm the configuration with your administrator or Waters service.
  • Processing multi-channel or 3D data fails or returns nothing. Use a method set rather than a single processing method, and make sure it includes the instrument, processing, report and export methods and any derived channels the data need.
  • A sample was acquired but not processed or reported. Check the Process column for that sample and the run mode chosen at the start; Don’t Process or Report and Don’t Report suppress those steps.
  • Backup or restore is unavailable. Backup needs the Backup Projects privilege and restore (Manage, Restore Project) needs the Restore Projects privilege. The restore folder must contain “Project Name.exp” and “Project Name.inf”.
  • You cannot print. On Windows 10, Start, Apps, Empower, Register Empower Node is the documented step for registering the node before using printers.

Alternatives to Empower

Other chromatography data systems exist, and which one a laboratory uses is usually decided by its instruments and validation history rather than by feature lists. Two pages on this site cover neighbouring tools.

Tool Type Where covered
Thermo Scientific Chromeleon Commercial chromatography data system Chromeleon guide
MZmine Free, open-source mass spectrometry data processing MZmine guide

MZmine processes mass spectrometry data and does not control instruments, so it replaces only the processing step. If you are deciding between HPLC, UPLC and UHPLC systems that Empower would drive, see HPLC vs UPLC vs UHPLC.

Frequently asked questions

What is Waters Empower software?

It is Waters’ chromatography data software: a Windows-based system that acquires, processes and manages chromatographic data from linked instruments, storing methods, results and raw data in projects.

Which Empower interface should I use?

The guide describes QuickStart for guided tasks, Pro for full control by administrators and advanced users, and Walk-Up for routine submission without deep chromatography knowledge. Your administrator decides which are allowed.

What is the difference between a sample set and a result set?

A sample set is the bound raw data from a run; a result set is the bound results produced by processing it with a processing method.

Can Empower process data without running samples?

Yes. The guide notes you can process data after acquisition or data imported from other sources or locations, interactively or in the background.

Which Empower version does this guide cover?

The documented edition is the Empower 3 Getting Started Guide, part 715005480 Rev A, dated 15 August 2017. Check the documentation for the release installed in your laboratory.

Sources

Data: Empower 3 method types and what each specifies

Compiled from Table 1-1 (Types of methods) of the Waters Empower 3 Getting Started Guide Rev A; each row gives a method type, what it specifies and the stage of the workflow it serves.

Period covered: 2017.

Empower 3 method types and what each specifies
Method typeWhat it specifiesWorkflow stage
InstrumentControl parameters for pumps, solvent management systems, detectors, autosamplers, sample management systems and gas chromatographsAcquisition
ProcessingIntegration parameters, calibration parameters (non-MS) and component identification for a 2D or 3D extracted channelProcessing
Sample Set MethodFunctions and parameter settings used to acquire data from a set of vials or samplesAcquisition
Sample Set Method TemplatePreset sample parameters for reuse; prompts for parameters not defined in the templateAcquisition
ReportLayout of results and calibration curves on the printed pageReporting
ExportData to export and file format: ASCII, AIA, OpenLynx, PDF or EMFExport
Method SetA group of methods applied togetherGrouping

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Waters Empower Software: Workflow, Methods and Results

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →