Skip to main content
v2026.11,986 entries · CC-BY 4.0

Emulsion PCR: How Water-in-Oil Droplet Amplification Works

Emulsion PCR amplifies single DNA molecules in water-in-oil droplets. Learn the principle, formulations, types, uses in NGS and SELEX, and what to record.

Written and maintained by CASRAI Editorial Board

Published

On this page

Emulsion PCR is polymerase chain reaction run inside millions of tiny water droplets suspended in oil, so that each droplet works as its own miniature reaction tube. Because individual DNA molecules are separated from one another, rare targets are not swamped by abundant non-target DNA and amplification stays closer to the original proportions of the sample. The format sits underneath next-generation sequencing library enrichment, aptamer selection (SELEX) and droplet digital PCR.

This guide explains the principle, the oil-and-surfactant chemistry, the two main variants, the bead-based BEAMing method, where each is used and what a bench scientist should record. It draws mainly on a 2019 review by Chai in the Journal of Animal Reproduction and Biotechnology and on the original BEAMing literature; the formulation comparison is in the data table below the article.

Definition and scope: what emulsion PCR is

What is PCR and why is it used?

PCR is a laboratory technique for rapidly producing millions to billions of copies of one specific segment of DNA, so that the segment can be studied in more detail (National Human Genome Research Institute glossary, read 2026-11-20). Short custom DNA pieces called primers select the region, and repeated copying cycles multiply it. In the review used for this guide, the aim of PCR is described as replicating and amplifying target sequences on a template that is surrounded by non-target DNA, with the reaction driven by interactions between the DNA template, polymerase, primers, nucleotides and minerals. The same review states that PCR can identify fewer than ten target sequences among millions of non-target molecules. For the building blocks of a reaction see our guides to master mix in PCR and the function of primers in a PCR reaction.

What is an emulsion?

An emulsion is a mixture of two liquids that do not mix, in which one is dispersed as droplets in the other. In emulsion PCR the reaction components (template DNA, polymerase, primers, nucleotides and minerals) are soluble in water but not in oil. Water and oil are immiscible because they have different surface energy properties, so a surfactant is added to mediate between the two and allow water to be dispersed in oil. The result is a water-in-oil emulsion: aqueous PCR droplets surrounded by a continuous oil phase. Our guide to the oil-in-water emulsion covers the opposite arrangement; emulsion PCR needs the water-in-oil form.

What is the problem emulsion PCR addresses?

Conventional PCR is hampered by non-specific reactions between primers and non-target DNA. The review reports that this can produce false negatives in infectious disease and cancer testing, and that low-frequency DNA variants can be lost when PCR is used to enrich metagenomic specimens or DNA aptamers. A clinical specimen may contain only a few viral or bacterial DNA molecules among millions of host DNA molecules, and the size of genomic DNA and cDNA libraries frequently exceeds one million sequences. Compartmentalising individual DNA molecules in aqueous droplets isolates target DNA from non-target DNA, which avoids some of these challenges.

How emulsion PCR works in practice

The oil phase, the surfactants and the aqueous phase

According to Chai (2019), the surfactants frequently used for emulsion PCR include Tween 80, Span 80, Triton X-100, ABIL EM 90, ABIL WE 09 and fluorinated silicone. The oil phase can be mineral oil, Tegosoft DEC (diethylhexyl carbonate) or silicone oil, and surfactants are generally added to the oil phase. Depending on the method, a 20-200 µL volume of aqueous PCR phase is added to the oil phase to make a 100-300 µL emulsion.

How the droplets are made

The aqueous phase can be dispersed with a vortex mixer, a magnetic stirrer or a microfluidic device. Vigorous mechanical agitation produces very large numbers of irregularly sized droplets, reported as a mean diameter of 4-6 µm. Microfluidic droplet generators instead give precise control of droplet number and diameter. The Bio-Rad QX200 Droplet Digital PCR System described in the review generates about 100,000 droplets of about 120 µm diameter from 20 µL of aqueous phase and 70 µL of oil phase. Droplet digital PCR is the digital form of the method.

Why BSA appears in the aqueous phase

In both published formulations compared in the data table, bovine serum albumin is included in the aqueous PCR phase to prevent denaturation of the polymerase at the water-oil interface (Diehl et al., 2006; Williams et al., 2006, as cited by Chai). The same two formulations use 0.2 mM dNTPs in the aqueous phase.

Why droplet contents follow a Poisson distribution

If equally sized droplets are dispersed in the oil, the number of molecules of any given component inside a droplet follows a Poisson distribution. Chai applies this to the polymerase, primers and dNTPs: with about 109 droplets, essentially every droplet holds enough polymerase, primers and dNTPs for PCR, so the limiting factor is whether a droplet contains a template molecule at all. Template molecules, being far fewer than droplets, are compartmentalised one to a droplet in most cases, which is what isolates each target from the non-target DNA.

Droplet stability and coalescence

The viscosity of the oil changes with temperature. As temperature rises and falls during cycling, droplets circulate, collide and can coalesce. Coalescence compromises the Poisson distribution and therefore emulsion PCR performance. The review notes that coalescence can be minimised when the amplification is run isothermally, and that loop-mediated isothermal amplification in fluorescence-based emulsion PCR has been reported to give superior amplification efficiency and specificity compared with earlier methods, without needing a thermal cycler. It also lists the need for precise optimisation of PCR conditions, and the possibility of emulsions losing stability when temperature fluctuates, among the limitations of the approach.

Types of emulsion PCR

Chai divides emulsion PCR methods into two categories. The comparison below is built from that review.

Feature Conventional emulsion PCR Fluorescence-based emulsion PCR
What the droplets contain Standard PCR components PCR components plus a fluorescent dye (SYBR Green, EvaGreen) or probe (TaqMan)
How droplets are usually generated Vortexing, stirring or microfluidics; about 109 droplets from agitation Generally microfluidic devices
Readout None inside the emulsion; the emulsion is broken and DNA recovered Fluorescence in individual droplets, applied to digital PCR
Typical purpose Enriching low-frequency targets among up to about 109 non-target molecules Detecting and quantifying single target molecules
Follow-up step Conventional PCR on the recovered DNA Droplet counting
Main practical drawback DNA recovery from the emulsion is described as tedious and complicated dNTPs in each droplet may run out before the recommended cycle number

Conventional emulsion PCR and why a second PCR follows

In conventional emulsion PCR the emulsion is broken after cycling and the enriched DNA is collected. Recovery described in the review uses organic solvents (diethyl ether, ethyl acetate and isobutanol), centrifugation to recover the aqueous phase, and purification with a commercial kit. Chai calculates that, in a droplet with a single template molecule at 0.2 mM dNTP, the dNTPs would be used up after about 16 cycles of a 500 bp amplicon, producing roughly 36,000-63,000 copies. That is not enough to identify by electrophoresis, so conventional PCR is used afterwards to amplify the enriched molecules. This figure is the author’s own calculation, not a measurement.

Fluorescence-based emulsion PCR and droplet digital PCR

When a dye or probe is included, amplification can be seen in individual droplets, which is the basis of droplet digital PCR. For the QX200 system the review reports a manufacturer-recommended dNTP concentration of 0.8 mM and a recommended 40 cycles, and the author’s calculation suggests dNTPs in a droplet could be exhausted after about 28 cycles for a 500 bp amplicon. The review states that fluorescence-based methods can quantify even a single target molecule mixed with non-target DNA.

BEAMing: emulsion PCR on beads

BEAMing (beads, emulsion, amplification, magnetics) was introduced by Dressman, Yan, Traverso, Kinzler and Vogelstein in PNAS in 2003. Each DNA molecule is converted to a single magnetic particle carrying thousands of identical copies of that molecule. The particles can then be analysed with a flow cytometer: variants are identified with fluorescently labelled probes and counted, millions of molecules can be assessed with standard laboratory equipment, and variants of interest can be isolated by flow sorting. The authors presented it as a way to detect and quantify rare mutations. Two companion papers on microparticle emulsion PCR appeared in Nature Methods in 2006 (Diehl et al., BEAMing, and Williams et al., amplification of complex gene libraries).

Where emulsion PCR matters in the lab

Unbiased enrichment for next-generation sequencing

Some DNA variants in a specimen are too rare for sequencing and must be enriched first. Chai reports that conventional PCR enrichment is biased toward short or high-frequency variants and toward sequences that match the polymerase’s preference. His worked illustration: a variant that is 1.5 times as abundant as another becomes about 191,751 times as abundant after 30 cycles (1.5 raised to the 30th power), because small differences compound. Emulsion PCR, by amplifying each molecule in its own compartment, is meant to preserve the original proportions, and the review says it is included in many NGS methods for unbiased enrichment. For the sequencing workflow itself see NGS DNA sequencing.

Aptamer selection (SELEX)

SELEX selects aptamers from a library of about 1015 sequences, with selection and enrichment repeated until the aptamer of interest is identified. The review describes emulsion PCR as the standard method for enriching aptamer candidates in SELEX, because it avoids PCR by-products and the loss of low-frequency candidates that conventional PCR causes.

Digital quantification and rare-variant detection

Fluorescence-based emulsion PCR underlies droplet digital PCR. Chai cites examples including pathogen quantification at 1-10 E. coli per mL of blood (Kang, 2014) and a droplet digital assay for KRAS mutations in circulating tumour DNA reported as 13% more sensitive than NGS (Demuth, 2018). These are reported results from the cited studies, and sensitivity depends on the assay and specimen.

What to record in a methods section

Because the stated failure points are droplet stability, droplet size and number, and recovery, a reproducible record would note the following. This list is an editorial summary of the factors the sources identify, not a standard.

  • The oil, the surfactants and their percentages, and the ratio of aqueous to oil phase.
  • How the droplets were made (vortex, stirrer or microfluidic device) and the resulting droplet size and number, if measured.
  • Whether BSA or another stabiliser was added to the aqueous phase, and the dNTP concentration.
  • The cycling program and cycle number, and whether the amplification was thermal-cycled or isothermal.
  • For conventional emulsion PCR, how the emulsion was broken and the DNA recovered, and what second-round PCR followed.

The general reaction set-up that sits under all of these is covered in PCR protocol basics.

Common misunderstandings

Emulsion PCR is not the same as droplet digital PCR

Droplet digital PCR is one fluorescence-based form of emulsion PCR. Conventional emulsion PCR is a separate use of the same principle, aimed at enrichment rather than counting.

The emulsion is not a pre-made reagent you simply add

The published methods make the emulsion fresh from an aqueous phase and an oil phase with surfactants. The two formulations in the data table differ in oil, surfactants, ratios and aqueous volume, which is why results are not directly comparable across protocols without recording these details.

The product of conventional emulsion PCR is usually not the final readout

Because dNTPs in a single droplet are limited, the amplicon yield from the emulsion step alone is small; the DNA is recovered and amplified again.

More droplets do not fix a poor emulsion

Coalescence changes droplet contents away from the Poisson distribution the method relies on, so unstable emulsions undermine the single-molecule logic however many droplets start out.

Frequently asked questions

What is PCR and why is it used?

PCR is a laboratory technique that amplifies one targeted DNA segment into millions to billions of copies so it can be studied (NHGRI). It is used wherever a small amount of a specific sequence must be detected, enriched or analysed, including infectious-disease testing, cancer testing and sequencing library preparation.

What is an emulsion?

An emulsion is one liquid dispersed as droplets in another liquid it does not mix with. Emulsion PCR uses a water-in-oil emulsion, held together by surfactants, in which each aqueous droplet is a separate reaction.

What happens if too much primer is in PCR?

The sources used here give no threshold for primer excess. They do identify non-specific reactions between primers and non-target DNA as a main cause of false negatives and lost low-frequency variants in conventional PCR, which is one motivation for compartmentalising reactions. For primer design and concentration in a standard reaction, see the primer guide linked above and the primer concentration given by your polymerase manufacturer.

What is the normal range of PCR?

There is no single range, because it depends on the reaction. For emulsion PCR the review reports 20-200 µL of aqueous phase made into a 100-300 µL emulsion, 0.2 mM dNTPs in conventional formulations, and a manufacturer recommendation of 40 cycles for the droplet digital PCR system it describes. Standard reaction conditions are set out in the PCR protocol basics guide linked above.

Sources

Data: Published emulsion PCR formulations and droplet-generation parameters

Compares the oil phase, surfactant composition, aqueous-to-oil volumes, BSA use, dNTP concentration and droplet generation of two published conventional emulsion PCR formulations and one commercial droplet digital PCR system, compiled from a 2019 peer-reviewed review (Chai) that summarises the original methods.

Period covered: 2006/2019.

Published emulsion PCR formulations and droplet-generation parameters
MethodAqueous PCR phase (µL)Oil phase (µL)Oil and surfactant compositionBSA in aqueous phasedNTP in aqueous phase (mM)Droplet generation
Williams et al. 2006 (conventional)200400Mineral oil with 4.5% Span 80, 0.4% Tween 80 and 0.05% Triton X-100Yes0.2Mechanical dispersion (about 10^9 droplets in the conventional methods)
Diehl et al. 2006 / Schütze et al. 2011 (conventional)15060073% Tegosoft DEC, 20% mineral oil, 7% ABIL WE 09Yes0.2Mechanical dispersion (about 10^9 droplets in the conventional methods)
Bio-Rad QX200 droplet digital PCR (fluorescence-based)2070Silicone oil and fluorinated oil with surfactants (proportions not stated)Not stated0.8Microfluidic generator; about 10^5 droplets of about 120 µm

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Emulsion PCR: How Water-in-Oil Droplet Amplification Works

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →