Written and maintained by CASRAI Editorial Board
Published
On this page
The EPA Integrated Risk Information System (IRIS) is a U.S. Environmental Protection Agency program that publishes assessments of the health effects of chemicals, either a single chemical, a group of related chemicals or a mixture. Each assessment can supply a reference dose, a reference concentration and cancer values. EPA describes these values as the first two steps of the four-step risk assessment process, not as regulatory levels.
Short answer
IRIS covers hazard identification and dose-response assessment. It does not do exposure assessment or risk characterization, which are left to EPA program and regional offices. For anyone in a laboratory, environmental health or research-support role, the practical consequence is that an IRIS value is an input to a risk judgement and not a limit that applies by itself. EPA’s own landing page also asks users to confirm that IRIS assessments are fit for their intended purpose and consistent with current science before relying on them.
Definition and scope
EPA states that IRIS assessments cover one chemical, a group of chemicals or a complex mixture, and that EPA program and regional offices use them in environmental risk decisions. The assessments are chronic-exposure oriented: the non-cancer values describe a lifetime of exposure, and the cancer values are expressed as lifetime risk. They are published on the IRIS website, where they can be found through an A to Z list of chemicals, a browse by organ or system, a separate A to Z list of assessments in development, and a search by chemical name, CASRN or keyword.
Two scope points matter for anyone citing IRIS. First, an assessment can be about a mixture, so the chemical you are looking for may sit inside a group assessment. Second, an assessment in development is a different object from a final one: IRIS keeps the two on separate lists, so a chemical appearing in the development list has no final posted values yet.
How an IRIS assessment is built
EPA describes seven steps from draft to posting. The sequence is worth knowing because it tells you how much review stands behind a posted value and where public input enters.
| Step | What EPA says happens |
|---|---|
| 1. Draft development | EPA scopes the assessment and frames the problem: exposure routes, health effects, study types and key science issues. It drafts a protocol for its systematic review and dose-response methods, releases preliminary materials for input and may hold a public science meeting. |
| 2. Agency review | EPA program office and regional scientists review the draft. |
| 3. Interagency science consultation | EPA leads other federal agencies in reviewing the draft. |
| 4. Public comment and external peer review | After revisions, the draft and charge questions are released for public comment and external peer review. |
| 5. Revision | The assessment is revised to address comments and peer review, and a disposition of comments is prepared. |
| 6. Final agency review and interagency discussion | EPA program offices, regions and other federal agencies review the revised assessment. |
| 7. Final assessment | The final assessment is posted to the IRIS website. |
Two supporting tools are named by EPA. HERO (Health and Environmental Research Online) is a searchable database of more than 1.6 million scientific studies and other references used in EPA assessments, and since 2010 citations in new IRIS assessments link to HERO records. That means a reader can trace a value back to the underlying study list. BMDS (Benchmark Dose Software) is EPA’s software for benchmark dose modeling, which EPA calls its preferred approach for deriving the points of departure that toxicity values are built from; it fits mathematical models to human and animal dose-response data.
IRIS value types, side by side
A single IRIS assessment can contain several kinds of value, and they answer different questions. The data table below sets the five value types against their route, unit where EPA states one, and meaning. The notes here cover how they relate.
Non-cancer values: RfD and RfC
The reference dose (RfD) is the oral value: a daily oral exposure estimate that is likely to be without appreciable risk of deleterious effects over a lifetime, including for sensitive subgroups. The reference concentration (RfC) is the inhalation counterpart, framed as a continuous inhalation exposure estimate, with EPA noting that the uncertainty spans perhaps an order of magnitude. Both are derived from a no-observed-adverse-effect level (NOAEL), a lowest-observed-adverse-effect level (LOAEL) or a benchmark dose or concentration. The practical point is that the route decides which one applies: an oral value cannot be swapped in for an inhalation question.
Cancer values: descriptor, OSF and IUR
The cancer descriptor is a category rather than a number. EPA lists five: Carcinogenic to Humans; Likely to Be Carcinogenic to Humans; Suggestive Evidence of Carcinogenic Potential; Inadequate Information to Assess Carcinogenic Potential; and Not Likely to Be Carcinogenic to Humans. Where a quantitative estimate is derived, it takes one of two forms. The oral slope factor (OSF) is an upper bound, approximating a 95% confidence limit, on the increased cancer risk from a lifetime oral exposure, expressed as the proportion affected per mg/kg-day. The inhalation unit risk (IUR) is the upper-bound excess lifetime cancer risk estimated to result from continuous exposure at 1 µg/m³ in air (EPA also gives 1 µg/L in water). Each is multiplied by a lifetime exposure to estimate lifetime risk.
An illustrative calculation
The arithmetic below uses invented numbers, not an IRIS value for any chemical, and exists only to show how the slope factor is applied. Suppose a hypothetical oral slope factor of 0.01 per mg/kg-day and a hypothetical lifetime exposure of 0.001 mg/kg-day. The estimated upper-bound lifetime risk is 0.01 × 0.001 = 0.00001, or 1 in 100,000. Because the slope factor is an upper bound, the result is an upper-bound estimate, not a prediction of cases. Deciding what exposure figure to use is exposure assessment, which is outside what IRIS itself provides.
What IRIS does and does not cover
EPA places IRIS inside the National Research Council’s four-step description of risk assessment, which the NRC framed in 1983 as the characterization of the potential adverse health effects of human exposures to environmental hazards.
| NRC step | Question it answers | Who does it, per EPA |
|---|---|---|
| 1. Hazard identification | Which hazards are credible? | IRIS |
| 2. Dose-response assessment | What is the quantitative relationship used to derive toxicity values? | IRIS |
| 3. Exposure assessment | What exposure pathways and amounts apply? | EPA program and regional offices |
| 4. Risk characterization | What does exposure combined with IRIS hazard and toxicity information imply for public health? | EPA program and regional offices |
Where it matters for labs and environmental health work
IRIS values appear wherever someone needs a documented toxicity reference for a chemical: preparing a hazard summary for a protocol, writing the toxicology section of an environmental health study, or reconciling a chemical’s hazard classification across databases. The IRIS landing page supports a short checklist to run before relying on a value.
- Is the value being used as a regulatory level? EPA says IRIS values are not necessarily intended for use as regulatory levels. If a regulatory limit is needed, it has to come from the program that sets it.
- Does the route match? RfD and OSF are oral values; RfC and IUR are inhalation values.
- Is the assessment fit for the purpose and current? EPA’s landing page asks users to confirm that the assessment and information are fit for the intended purpose and consistent with the most current scientific literature, so note the assessment’s own date and check HERO references for newer studies.
- Is the chemical’s assessment final? A chemical on the in-development list has no final posted values.
- Have you read the current notice? The page carries an alert about an April 27, 2026 EPA Deputy Administrator memorandum, described below.
The April 2026 memorandum
As described on the IRIS landing page (last updated August 27, 2026), the memorandum asks EPA program offices to consider whether IRIS information is fit-for-purpose and represents best available science. It also says external entities that relied on earlier IRIS assessments should consider undertaking a review, and that review action is encouraged to ensure any decision or reliance was accurately and properly implemented. Anyone who has cited an IRIS value in a protocol, safety document or report should read that alert directly and decide whether their reliance needs rechecking.
Related CASRAI guides
IRIS is one of several free chemical-information resources, each answering a different question. The CompTox Chemicals Dashboard guide covers EPA’s chemical property and bioactivity data; the IARC list of carcinogens guide covers a separate hazard classification scheme from the International Agency for Research on Cancer, whose categories are not the same as the IRIS cancer descriptors; the ECOTOX database guide covers ecological toxicity data; the Toxics Release Inventory guide covers reported chemical releases; and the Envirofacts guide covers EPA’s broader environmental data API. Using them together means keeping each one’s purpose distinct: a hazard value, a release record and an ecological endpoint are not interchangeable.
Common misunderstandings
An IRIS value is a legal limit
It is not necessarily so. EPA says the values are not necessarily intended for use as regulatory levels, and that they represent only the first two of four steps.
An RfD or RfC is a bright line between safe and unsafe
EPA defines these as estimates likely to be without appreciable risk, with the RfC carrying uncertainty spanning perhaps an order of magnitude. They are estimates, not thresholds.
A slope factor predicts how many people will get cancer
The OSF is an upper bound approximating a 95% confidence limit, and the IUR is an upper-bound excess lifetime cancer risk. Neither predicts a case count.
IRIS tells you the risk at a site or in a lab
Site or workplace risk needs an exposure assessment and a risk characterization, which EPA assigns to its program and regional offices, not to IRIS.
A cancer descriptor from IRIS and a classification from another body are the same thing
IRIS uses its own five descriptors. Other bodies use their own schemes and evidence reviews, so compare descriptors only after reading each scheme’s definitions.
Sources
- U.S. EPA, Welcome to the EPA’s Integrated Risk Information System (IRIS), https://www.epa.gov/iris (read 2026-11-15)
- U.S. EPA, Basic Information about the Integrated Risk Information System, https://www.epa.gov/iris/basic-information-about-integrated-risk-information-system (read 2026-11-15)
Data: EPA IRIS toxicity value types: route, unit and meaning
Compares the five kinds of value an EPA IRIS assessment can contain (RfD, RfC, cancer descriptor, oral slope factor, inhalation unit risk) by exposure route, unit where EPA states one, and what each estimates. Compiled from EPA's IRIS landing page and Basic Information page.
Coverage: United States.
| Value type | Exposure route | Unit as stated by EPA | What it estimates | Basis stated by EPA |
|---|---|---|---|---|
| Reference dose (RfD) | Oral | Not stated on the EPA pages; given in each assessment | Daily oral exposure likely to be without appreciable risk of deleterious effects over a lifetime, including sensitive subgroups | Derived from a NOAEL, LOAEL or benchmark dose |
| Reference concentration (RfC) | Inhalation | Not stated on the EPA pages; given in each assessment | Continuous inhalation exposure, with uncertainty spanning perhaps an order of magnitude, likely to be without appreciable risk of deleterious effects over a lifetime | Derived from a NOAEL, LOAEL or benchmark concentration |
| Cancer descriptor | Not route-specific | Category (five levels) | Weight of evidence for carcinogenic potential, from Carcinogenic to Humans to Not Likely to Be Carcinogenic to Humans | Five descriptors including Suggestive Evidence and Inadequate Information |
| Oral slope factor (OSF) | Oral | proportion affected per mg/kg-day | Upper bound, approximating a 95% confidence limit, on increased cancer risk from a lifetime oral exposure | Multiplied by lifetime exposure to estimate lifetime risk |
| Inhalation unit risk (IUR) | Inhalation | excess lifetime risk per µg/m³ (air) or per µg/L (water) | Upper-bound excess lifetime cancer risk from continuous exposure to an agent at 1 µg/m³ in air or 1 µg/L in water | Multiplied by lifetime exposure to estimate lifetime risk |
Sources
- EPA IRIS landing page (accessed 2026-11-15)
- Basic Information about the Integrated Risk Information System (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.