Excepted Quantities: 49 CFR 173.4a Limits, Marking and Paperwork

What 49 CFR 173.4a allows: eligible hazard classes, inner and outer limits, the mark, drop tests, paperwork and the difference from limited quantity.

Written and maintained by CASRAI Editorial Board

Published

On this page

Excepted quantities are very small amounts of certain hazardous materials that, when packed in the inner, intermediate and outer packagings 49 CFR 173.4a requires and marked with the excepted quantities mark, are exempt from most of the US Hazardous Materials Regulations. The shipper still has to classify the material, report incidents and follow the packaging, test, marking and documentation rules in that one section, and the shipment cannot go in checked or carry-on baggage.

Short answer: what is an excepted quantity?

An excepted quantity is a package whose hazardous contents stay within the per-inner and per-outer limits in 49 CFR 173.4a(c) and (d). Such packages are “not subject to requirements of this subchapter” except for three things: the shipper’s duty to classify the material under 49 CFR 173.22, the incident-reporting rules in 49 CFR 171.15 and 171.16, and, for Class 7 radioactive material, the excepted-package requirements. Laboratories meet the concept when they ship small vials of reagents, standards, solvents or samples, because a 30 mL inner container is a common laboratory size. The section is also where the confusion with limited quantities starts, so this guide separates the two.

This page covers the US rule in 49 CFR 173.4a as published in the eCFR and mirrored by Cornell’s Legal Information Institute. It does not reproduce the international air tables that carry their own codes, which sit in the IATA Dangerous Goods Regulations; see the IATA Dangerous Goods Regulations guide for that system. It is general regulatory information, not a classification of any particular substance.

Definition and scope

The Hazardous Materials Regulations (HMR) in 49 CFR Parts 171 to 180 normally apply in full to anything classed as a hazardous material. Section 173.4a is one of the exceptions written into Part 173. Its opening paragraph limits the exception to “materials, other than articles (e.g., aerosols)”, so it is a rule about substances in inner containers, not about manufactured articles.

The exception is also tied to air transport. Paragraph (b) says that only “materials authorized for transport aboard passenger aircraft” and classed in one of the listed hazard classes or divisions may move under the section. A material that is forbidden aboard passenger aircraft cannot be shipped as an excepted quantity by any mode under this section.

What stays in force

  • Classification. The shipper must still class the material correctly under 49 CFR 173.22. Whether a package qualifies depends on the hazard class or division and, for several classes, the packing group (see Packing Group I, II and III).
  • Incident reporting. Sections 171.15 and 171.16 still apply to a release or other reportable incident.
  • Liquid-holding packagings. Packagings whose basic function is to retain liquid must withstand the pressure differential in 49 CFR 173.27(c) without leakage.
  • Class 7. Radioactive material must meet the requirements for an excepted package.
  • Knowledge of the rule. Paragraph (i) requires each person who offers or transports excepted quantities to know the requirements of the section.

How an excepted-quantity package is built

Section 173.4a reads as a sequence of tests a package has to pass. The checks below follow the order of the paragraphs.

1. Is the material eligible?

Paragraph (b) lists what may be shipped as excepted quantities. The next section sets out the list in full, including the carve-outs.

2. Inner packaging limits

Paragraph (c) sets the maximum per inner packaging: 1 g for solids or 1 mL for liquids where the material has a Division 6.1 primary or subsidiary hazard and is Packing Group I or II; 30 g or 30 mL for other solids and liquids; and a water capacity of 30 mL or less for gases.

3. Outer packaging aggregate limits

Paragraph (d) caps the total hazardous material in each outer packaging: Packing Group I, 300 g or 300 mL; Packing Group II, 500 g or 500 mL; Packing Group III, 1 kg or 1 L; Division 2.2, 1 L; Division 5.2, 500 g or 500 mL. Where an outer packaging holds more than one hazardous material, the aggregate must not exceed the lowest permitted maximum.

4. Packaging construction

Paragraph (e) requires that each inner receptacle be made of plastic, glass, porcelain, stoneware, earthenware or metal, and that plastic inner packagings for liquids be at least 0.2 mm thick. A removable closure must be held in place with wire, tape or other positive means, and a receptacle with a molded screw-thread neck needs a leak-proof threaded cap that does not react chemically with the contents. Each inner packaging must be packed in an intermediate packaging with cushioning so that it cannot break, be punctured or leak under normal conditions of transport, and that intermediate packaging goes into a strong, rigid outer packaging. For liquids, the intermediate or outer packaging must hold enough absorbent material to take up the entire contents of the inner packaging, and the completed package must contain its contents in case of breakage or leakage whatever its orientation. The package must be big enough to carry all the markings, must not be opened or altered until it is no longer in commerce, and must not combine materials in a way that violates 49 CFR 173.21. Overpacks are allowed under 49 CFR 173.25.

5. Package tests

Paragraph (f) requires the completed package, with inner packagings filled to at least 95% of capacity for solids or 98% for liquids, to withstand tests “as demonstrated by testing which is appropriately documented”, without breakage or leakage of any inner packaging. The tests are drops from 1.8 m (5.9 feet) onto a solid unyielding surface and a compressive load as specified in 49 CFR 178.606(c). A box-shaped package is dropped flat on the bottom, flat on the top, flat on the longest side, flat on the shortest side and once on a corner at the junction of three intersecting edges. A drum-shaped package is dropped diagonally on the top chime, diagonally on the base chime and flat on the side. The tests need not all be done on the same package, but may be done on a different, identical one.

6. The excepted quantities mark

Paragraph (g) requires a durable, clearly visible square mark. The hatching is black or red on a white or suitably contrasting background, and the minimum size is 100 mm by 100 mm measured from the outside of the hatching that forms the border. The “*” is replaced by the primary hazard class (or, when assigned, the division) of each hazardous material in the package, and the “**” by the name of the shipper or consignee if that name is not shown elsewhere on the package. For air transport the entire mark must appear on one side of the package. If the mark is not visible on the package inside an overpack, it must also be placed on the overpack, which does not need the word “OVERPACK”.

7. Paperwork

Paragraph (h) sets documentation by mode. For highway or rail, no shipping paper is required. For air, a shipping paper is not required, but if a document such as an air waybill accompanies the shipment it must carry the statement “Dangerous Goods in Excepted Quantities” and the number of packages. For vessel, a shipping paper is required and must include that statement and the number of packages.

Which materials qualify

Paragraph (b) is the eligibility list. Reading it as a checklist gives the following, with the carve-outs that most often matter to laboratories.

Class or division Eligible under 49 CFR 173.4a(b) Excluded or restricted
Division 2.2 gases Division 2.2 with no subsidiary hazard Aerosols are not authorised Division 2.2 material
Class 3 flammable liquids Class 3 materials None listed in (b)
Class 4 flammable solids Packing Group II and III Self-reactive materials excluded
Division 5.1 oxidisers Packing Group II and III Packing Group I not listed
Division 5.2 organic peroxides Only when contained in a chemical kit, first aid kit or polyester resin kit Otherwise not eligible
Division 6.1 toxic substances Packing Groups other than I; not Hazard Zone A or B Packing Group I and Hazard Zone A or B excluded
Class 7 radioactive Radioactive material in excepted packages Excepted-package requirements still apply
Class 8 corrosives Packing Group II and III UN2803 (gallium) and UN2809 (mercury) excluded
Class 9 miscellaneous Class 9 materials UN1845 (solid carbon dioxide, dry ice) and lithium batteries and cells excluded

Two points follow from the list. Division 6.2 (infectious substances) does not appear in paragraph (b), so a Division 6.2 material is not eligible under this section. And dry ice, a common laboratory coolant, is specifically excluded from the Class 9 entry. See the Class 9 dangerous goods term for how that class is organised.

Excepted quantity versus limited quantity

The two exceptions are often treated as one. In the regulations they are separate sections with different limits, marks and paperwork rules. The table sets out what 49 CFR 173.4a and 49 CFR 173.150 and 172.315 each say.

Feature Excepted quantity (49 CFR 173.4a) Limited quantity (49 CFR 173.150, 172.315)
How quantity is limited Net amount per inner packaging and per outer packaging, by hazard class and packing group Gross weight per package of 30 kg (66 lb) maximum, plus the limits in the 172.101 table entry for the material
Where the exception is found Paragraph (b) list of classes; no entry in the hazardous materials table is needed Only if 173.150 is referenced for the material in the 172.101 table
Mark Hatched square, at least 100 mm by 100 mm, showing the hazard class and shipper or consignee name Square-on-point, at least 100 mm per side with a border of at least 2 mm; reduced sizes of 50 mm and 1 mm allowed for small packages; a black “Y” is centred for air
Package testing 1.8 m drops and compressive load, documented Packages must conform to the general packaging requirements of subpart B
Shipping paper None for highway, rail and air (air waybill statement if one accompanies); required for vessel Not subject to the subpart C shipping paper rules unless a hazardous substance, hazardous waste or marine pollutant, or offered by air or vessel and eligible under 173.156
Placarding Not subject to the HMR beyond the listed exceptions Conforming package not subject to the placarding rules of subpart F

The practical difference is the unit of measure. A limited-quantity package is controlled mainly by its gross weight and the per-material limit in the hazardous materials table. An excepted-quantity package is controlled by how much hazardous material is in each inner and in the outer, which is why very small vials suit it. For the broader table that carries those column entries, see the 49 CFR Part 172 guide.

How the limits work in practice: worked arithmetic

The following figures are arithmetic on the limits in paragraphs (c) and (d). They are not advice on any shipment, and the material’s class and packing group must be established first.

  • Packing Group III liquid in 30 mL inners. The outer limit is 1 L, or 1,000 mL. Thirty-three full 30 mL inners hold 990 mL, so a thirty-fourth (1,020 mL) would exceed it. At most 33 full inners fit under the limit.
  • Packing Group II liquid in 30 mL inners. The outer limit is 500 mL. Sixteen full inners hold 480 mL; a seventeenth (510 mL) would exceed the limit.
  • Packing Group I liquid in 30 mL inners. The outer limit is 300 mL, so ten full inners reach exactly 300 mL. (A Division 6.1 primary hazard in Packing Group I is not eligible at all, but a material with a Division 6.1 subsidiary hazard in Packing Group I or II is held to the 1 mL inner limit.)
  • Mixed contents. If one outer packaging holds a Packing Group III liquid and a Packing Group I liquid, the aggregate of all hazardous material must stay within 300 mL, the lower of the two limits.

Where it matters for labs

Laboratories ship reagents, analytical standards, solvents and prepared samples in small containers, which is the profile 49 CFR 173.4a was written for. Three points in the text bear on laboratory practice.

  • Classification comes first. The exemption does not remove the duty under 173.22 to identify the hazard class and packing group, and the limits are keyed to both.
  • Dry ice and lithium cells fall outside it. Paragraph (b)(9) excludes UN1845 and lithium batteries and cells, so a cold-chain parcel or a device with a battery is not an excepted-quantity package for those components. See hazmat shipping for medical supplies for related carrier-facing issues.
  • Training is still required. Paragraph (i) places a knowledge duty on everyone who offers or transports the package, including the person who packs it.

Common misunderstandings

“Excepted” means “exempt from everything”

It does not. The material must still be classified, incidents are still reportable, liquid-retaining packagings still face the 173.27(c) pressure differential, and the package must pass documented drop and compression tests.

Excepted quantity and limited quantity are the same thing

They are separate sections with different marks. The limited quantity mark is a square set on a point; the excepted quantities mark is a hatched square carrying the hazard class and the shipper or consignee name. Section 172.315, which covers the limited-quantity mark, does not cover the excepted quantities mark.

Any hazardous material qualifies if the container is small enough

Eligibility is set by paragraph (b). Aerosols, dry ice, lithium cells and batteries, Division 6.1 Packing Group I and several other categories are excluded regardless of container size.

A shipping paper is never needed

True for highway and rail. For air, an accompanying air waybill must carry the statement “Dangerous Goods in Excepted Quantities” and the package count. For vessel, a shipping paper with that statement and count is required.

Frequently asked questions

What is limited and excepted quantity?

Both are exceptions in 49 CFR Part 173 that reduce regulation for small amounts of hazardous materials. Limited quantity (49 CFR 173.150) is controlled by package gross weight, with a 30 kg (66 lb) maximum, and a material-specific entry in the hazardous materials table. Excepted quantity (49 CFR 173.4a) is controlled by net quantity per inner and per outer packaging, by hazard class and packing group.

What are the requirements for packages under the limited quantity exceptions?

Under 49 CFR 173.150, the exception applies only if 173.150 is referenced for the material in the 172.101 table and each package conforms to subpart B. Gross weight per package may not exceed 30 kg (66 lb). For air transport the package must also meet 49 CFR 173.27, only material authorised aboard passenger aircraft is covered, and combination packagings are not authorised for flammable liquids. The package carries the limited-quantity mark of 49 CFR 172.315: a square-on-point at least 100 mm per side with a border of at least 2 mm, with a reduced 50 mm and 1 mm form for small packages and a black “Y” for air.

What is forbidden for air transport?

For excepted quantities, 49 CFR 173.4a(b) limits the section to material authorised aboard passenger aircraft and excludes aerosols, UN1845 dry ice and lithium batteries and cells from the eligible classes; paragraph (j) bars these packages from checked or carry-on baggage. For limited quantities by air, 49 CFR 173.150 limits the exception to material authorised aboard passenger aircraft and does not authorise combination packagings for flammable liquids. Other air prohibitions are set in the IATA Dangerous Goods Regulations and the carrier’s own rules, which are not covered here.

How to ship hazardous materials?

The starting point is classification under 49 CFR 173.22, because every exception depends on the class and packing group. From there the shipper checks the hazardous materials table in 49 CFR 172.101, whose column 8A lists the exceptions available to each material, and then follows the matching section for packaging, marking, documentation and training. The 49 CFR Part 172 guide linked above covers the table.

Sources

Data: Excepted quantity limits per inner and outer packaging under 49 CFR 173.4a

Maximum quantity of hazardous material per inner packaging and per outer packaging for excepted quantities, by packing group, hazard division and kit condition, compiled from paragraphs (c) and (d) of 49 CFR 173.4a as published in the eCFR and mirrored by Cornell LII. Solids are in grams and liquids in millilitres; gas inner limits are water capacity in millilitres. Where the outer limit is set per packing group, the inner row notes that.

Excepted quantity limits per inner and outer packaging under 49 CFR 173.4a
CategoryMaximum per inner packaging (g or mL)Maximum aggregate per outer packaging (g or mL)Paragraph
Packing Group I (not Division 6.1 inner rule)30300173.4a(c)(2), (d)(1)(i)
Packing Group II30500173.4a(c)(2), (d)(1)(ii)
Packing Group III301000173.4a(c)(2), (d)(1)(iii)
Division 6.1 or subsidiary 6.1, Packing Group I or II (inner)1n/a: set by the packing group row173.4a(c)(1)
Division 2.2 gas (inner: water capacity)301000173.4a(c)(3), (d)(2)
Division 5.2 organic peroxide (kit only)30500173.4a(c)(2), (d)(3)

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Excepted Quantities: 49 CFR 173.4a Limits, Marking and Paperwork

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →