Written and maintained by CASRAI Editorial Board
Published
On this page
EXFOR is the international library and exchange format for experimental nuclear reaction data, maintained by the Nuclear Reaction Data Centres network under IAEA coordination. It preserves measurements with their experimental context. Reusing a result requires its subentry, units, explanatory information and revision date, rather than a cross-section number alone.
Short answer
EXFOR connects numerical results to the experiment that produced them. Its name derives from EXchange FORmat, and it refers both to the organized library and to the format used to exchange its records. The IAEA describes it as a resource for collecting, storing, exchanging and retrieving experimental nuclear reaction data.
The practical distinction is between an experimental result and a recommended evaluation. EXFOR preserves the former, including results from different investigators that may disagree. Evaluation libraries serve a different purpose. The data table below brings together the documentation on exchange records, computational output and archive snapshots so that a research group can identify which object it actually used.
Definition and scope
The International Network of Nuclear Reaction Data Centres, or NRDC, maintains EXFOR, coordinated by the IAEA Nuclear Data Section. In the IAEA’s Quick Guide to EXFOR, the organizing unit is a piece of experimental work. A record can combine information from a journal article, laboratory report and conference contribution describing that work.
This matters when reviewing the evidence behind a reaction measurement: several references can describe one experiment. Counting those references as independent datasets would misrepresent their relationship. Conversely, one entry can contain several numerical tables, separated into subentries. The entry identifies the work; the subentry identifies a particular dataset within it.
The documented quantities extend beyond a single cross section. They include integral and partial cross sections, angular and energy distributions, resonance parameters, fission product yields, product and thick-target yields, reaction rates and resonance integrals. Identify the measured quantity as well as the reacting nuclides before comparing results.
The user manual dates from June 2008. Its historical database totals and compilation-coverage descriptions should be read with that date attached. They are not present-day inventory statistics. For contemporary files, the IAEA provides the current Entry File and annual Master Files, discussed below.
How EXFOR is used in practice
Using EXFOR means retrieving a relevant experimental dataset and interpreting it together with its definitions. The IAEA exchange-format overview explains why the numerical table is only one part of that task.
Read the record hierarchy
An entry has a five-character accession identifier; a subentry has an eight-character subaccession identifier. The first subentry, numbered 001 within the entry, contains information shared by the other subentries. It does not contain the experimental-result table. Later subentries contain results and any information specific to those results.
BIB contains bibliographic, descriptive and administrative information. That can include authors, references, measurement methods, facilities and revision history. COMMON supplies parameters that apply across a table. DATA contains the point-by-point values, with headings and units. A result is interpreted through these connected sections, including the shared information in subentry 001.
Identify the quantity before plotting
The REACTION keyword specifies both the nuclear reaction and the measured quantity. A target and projectile alone do not establish that two datasets describe the same observable. The manual also explains pointers: characters that connect particular reactions or explanatory information to the appropriate fields in COMMON or DATA.
For reuse, our editorial recommendation is to record that definition before importing columns into an analysis. Keep the original headings and units alongside any renamed variables. A label such as “cross section” in a spreadsheet cannot preserve all the distinctions encoded in a reaction definition, particularly when several quantities share an entry.
Distinguish exchange and computational output
The IAEA user-output documentation describes the exchange format, interpreted EXFOR+ output and the computational format C4. C4 organizes individual data points into fixed fields and standardized units. It also carries identifiers and reference information linking those points back to EXFOR.
Its classification follows ENDF conventions with extensions for additional quantities and reactions. The manual cautions that not every EXFOR data type can be translated automatically into C4. It also states that output availability can differ between centres. An export format therefore needs to be named explicitly; “downloaded EXFOR” does not identify the representation used.
C4 also has a field distinguishing laboratory and centre-of-mass reference frames, as well as fields for target and residual-nucleus states. Those distinctions belong with the plotted values. As an editorial check, compare the field definitions before joining two exported series: matching target labels alone do not establish that their frames, states and measured quantities match. Keep uncertainty fields with the values they describe. The manual’s fixed layout identifies incident-energy uncertainty separately from uncertainty in the measured data, so these columns should not be collapsed into one unnamed error column during import.
Types and related nuclear data resources
The Japan Atomic Energy Agency’s Selected Links to Nuclear Data separates evaluated reaction libraries, experimental data, bibliographies and nuclear properties. That organization provides a useful map for deciding which kind of evidence a research question needs.
EXFOR sits in the experimental-data category. ENDF/B, JEFF and JENDL are listed among evaluated reaction libraries. A comparison between measured points and an evaluated curve therefore brings together distinct products, rather than two interchangeable downloads. Our guide to ENDF and evaluated nuclear data explains the evaluation-library side of that comparison.
Nuclear structure and decay are another category. The JAEA directory lists ENSDF and nuclide-chart resources separately from experimental reaction data. For readers tracing that distinction, the NuDat nuclear structure and decay guide covers the neighbouring resource. Selecting a database by the property sought is more precise than treating every nuclear-data website as a general lookup service.
The directory also lists several routes to EXFOR, including IAEA, NNDC, JANIS and JCPRG services. These are access routes to the experimental-data domain, rather than evidence that every interface has identical controls or offers the same export options.
Where EXFOR matters for laboratory research
EXFOR matters where a research group needs to connect a reaction result to its underlying measurement. The IAEA documentation explicitly retains experimental descriptions, corrections, error analysis and reference standards alongside numerical data. Those elements make a result interpretable beyond the graph or table that first attracted the reader.
For a nuclear or radiochemistry research project, one possible use is reviewing measurements behind a product-yield or reaction-cross-section comparison. This is an application of the documented data categories, not a claim that EXFOR prescribes an experimental protocol. The relevant work remains the measurement, its stated conditions and its uncertainties.
For a data analyst, the useful distinction is between the archival representation and a transformed table prepared for computation. For a laboratory’s data steward, it is between a changing current collection and a fixed annual snapshot. These are editorial applications of the documented record and release structure. They concern traceability of research inputs, not equipment selection, clinical performance or treatment decisions.
These records can be incorporated into a project’s documentation of data provenance: identify the source object, retain its version information and explain transformations. A later reviewer should be able to distinguish a change in the source record from a change introduced during analysis.
Worked example: reading a dataset in context
The following is an illustrative reading scenario based on the IAEA format description, not a reported experiment or a set of invented measurement values. Suppose a researcher retrieves a result subentry containing a table of a measured quantity against energy.
The researcher first reads the entry’s shared subentry 001, then the selected subentry’s own BIB information. This establishes which references and experimental descriptions apply. Reading only the local table would lose shared context; reading only the general subentry would miss information specific to the selected dataset.
Next, the researcher checks REACTION to establish the observable and reads both COMMON and DATA. A parameter constant across all points can be in COMMON rather than repeated in DATA. In a simplified analysis worksheet, that parameter should remain associated with every point to which it applies. It should not disappear because it was absent from the exported numerical columns the analyst initially selected.
If pointers distinguish multiple reactions or fields, the researcher follows those associations before combining columns. The unit row is retained. Blank fields remain distinguishable from measured zeros. The original record and its date stay with the derived worksheet.
Finally, if the comparison uses C4, the researcher records that representation and checks the translated field definitions. The original exchange record remains available for context. This example illustrates a documentation check, not an instruction to derive a recommended cross section or average conflicting experimental results.
Preserving and citing EXFOR data
The IAEA’s EXFOR Master File page describes an annual, end-of-year snapshot containing entries and the EXFOR/CINDA dictionary. Its Entry File page describes the official current snapshot containing the latest versions of those objects. The latter points readers to the Master File for annual snapshots.
These objects answer different preservation needs. For an analysis tied to a named annual release, retain that release designation. For a download from the current collection, retain the file and retrieval date. This is our preservation recommendation based on the IAEA’s snapshot distinction, rather than an additional IAEA submission requirement.
The EXFOR Basics citation guideline includes the original authors, an EXFOR data-file identifier, its date, the related publication and the retrieval centre. Separately, the Master File terms require users redistributing it or using it in a publication to indicate the version and cite the EXFOR reference article. The Master File is distributed under CC BY 4.0.
Our editorial checklist combines those instructions with the documented record structure:
- Identify the exact subentry and record date, alongside the original experimental reference.
- Name the centre or service used for retrieval and retain the downloaded object.
- Record whether the input was exchange format, C4 or another representation.
- Preserve shared metadata, units, status information and any transformations applied during analysis.
- For a Master File, retain its release designation and the required reference-article citation.
Common misunderstandings
EXFOR supplies a single recommended value
The IAEA distinguishes experimental compilation from evaluation. Different experimental results can coexist without agreement. Selecting a value for a model is a separate scientific judgment; the database’s inclusion of a result does not make it a recommended evaluation.
A table is self-contained
The format deliberately avoids repeating shared information. Subentry 001 and COMMON can supply context absent from an individual row. A row copied without that context can be incomplete even when every copied digit is correct.
A computational export is the original record
C4 standardizes representation for processing and comparison. Its status and reference fields still matter: the documented codes include preliminary, renormalized and superseded data. The presence of a numeric point does not erase its status or the transformation that produced the computational representation.
An annual snapshot is the current collection
The IAEA explicitly distinguishes the annual Master File from the current Entry File. A year-labelled archive serves reproducibility, while a current snapshot serves access to the latest compiled versions. State which one underlies the analysis so a reader knows which data object to retrieve.
Sources
- IAEA Nuclear Data Section, EXFOR Formats Description for Users, IAEA-NDS-206, June 2008: preface and citation guideline. Checked 2026-11-17.
- IAEA Nuclear Data Section, EXFOR Basics I: A Quick Guide to EXFOR. Checked 2026-11-17.
- IAEA Nuclear Data Section, EXFOR Basics II: Overview of the EXFOR Exchange Format. Checked 2026-11-17.
- IAEA Nuclear Data Section, EXFOR Basics III: User Output Formats. Checked 2026-11-17.
- IAEA Nuclear Data Section, EXFOR Master File. Checked 2026-11-17.
- IAEA Nuclear Data Section, EXFOR Entry File. Checked 2026-11-17.
- Japan Atomic Energy Agency, Selected Links to Nuclear Data. Checked 2026-11-17.
Data: EXFOR records, computational output and library snapshots
A cross-source comparison compiled from IAEA record-format, output-format and archive documentation. It distinguishes the contents and representation of experimental records from the current and annual library snapshots; it contains no measured nuclear values.
| Data object | Contents | Representation or time basis | Documented identifiers or version | Source |
|---|---|---|---|---|
| EXFOR exchange record | BIB information, shared parameters and experimental data tables | Entry and subentry hierarchy | Five-character accession; eight-character subaccession; update date | https://www-nds.iaea.org/nrdc/basics/exfor-basics-2.html |
| C4 computational output | Individual data points in fixed fields and standardized units | Point-oriented translation from EXFOR | EXFOR accession/subaccession and first-author/year fields | https://www-nds.iaea.org/nrdc/basics/exfor-basics-3.html |
| EXFOR Entry File | Latest versions of all entries and EXFOR/CINDA dictionary | Official current snapshot | Page supplies a last-updated date | https://www-nds.iaea.org/nrdc/exfor-master/entry/ |
| EXFOR Master File | All entries and EXFOR/CINDA dictionary at year end | Official annual snapshot | Release version must be indicated for redistribution or publication | https://www-nds.iaea.org/nrdc/exfor-master/ |
Sources
- EXFOR Basics II: Overview of the EXFOR Exchange Format (accessed 2026-11-17)
- EXFOR Basics III: User Output Formats (accessed 2026-11-17)
- EXFOR Entry File (accessed 2026-11-17)
- EXFOR Master File (accessed 2026-11-17)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







