Written and maintained by CASRAI Editorial Board
Published
On this page
Experimental mechanics is the measurement side of mechanics: it uses physical tests and instruments, such as tension tests, bonded strain gages, extensometers and digital image correlation, to measure how materials, structures and systems deform and respond to load. The Society for Experimental Mechanics (SEM) describes its aim as providing the physical basis and verification for analytical and computational approaches, so that a calculated or simulated result can be checked against a measured one.
Short answer: what experimental mechanics is
Experimental mechanics is the practice of measuring mechanical behaviour directly instead of only calculating it. SEM, the main professional society for the field, says its members work in academia, government and industry and are committed to the interdisciplinary application, research, development and education of experimental methods. In a laboratory this usually means three things: a test method (how the specimen is loaded), a measurement method (how force, length change or strain is recorded) and a governing document that fixes how both are done so results can be compared between labs.
The data table below lists four such governing documents, what each one covers, and its status as read on the ASTM and iDICs pages on 2026-11-20.
Definition and scope
SEM’s own site does not give a one-line definition of the field. What it does state is the purpose: to increase knowledge of physical phenomena, to understand how materials, structures and systems behave, and to supply the physical basis and verification for analytical and computational approaches. That purpose explains the scope. Experimental mechanics is not tied to one material or one machine; it is a set of methods for measuring displacement, strain, force and related quantities, and for judging how far a measurement can be trusted.
The society’s history shows how the field was framed. SEM was founded in 1943 as the Society for Experimental Stress Analysis, with the original goal of furthering the knowledge of stress and strain analysis and related technologies, and it has since been renamed. SEM lists these publications on its site: the journal Experimental Mechanics, the journal Experimental Techniques (which the site describes as bimonthly), the Journal of Dynamic Behavior of Materials, the SEM Book Series and the newsletter Experimentally Speaking. It also lists conferences including IMAC, the SEM Annual Conference and the iDICs Conference.
How experimental mechanics is used in practice
In practice a measurement result is only as useful as the document that says how it was produced. Three families of method show this clearly.
Tension and compression testing
ASTM E8/E8M-25, Standard Test Methods for Tension Testing of Metallic Materials, is an active standard maintained by ASTM Committee E28 (subcommittee E28.04), last updated 26 August 2025. It covers tension testing of metallic materials in any form at room temperature, and it is used to determine yield strength, yield point elongation, tensile strength, elongation and reduction of area. For round specimens the standard uses a gauge length of 4 times the diameter in the inch-pound version (E8) and 5 times the diameter in the SI version (E8M), with powder metallurgy materials treated separately. Room temperature is taken as 10 to 38 °C unless a different range is specified, and the standard notes that the SI and inch-pound values are not exact equivalents, so each system is to be used on its own terms.
The significance statement is the most useful part for a lab manager. The standard says tension tests provide strength and ductility information under uniaxial tensile stress, that the results are used for comparing materials, developing alloys, quality control and design, and that results from a specimen may not represent the behaviour of the whole product. Compression is handled separately: ASTM E9-19(2025), Standard Test Methods of Compression Testing of Metallic Materials at Room Temperature, covers the apparatus, specimens and procedure for axial-force compression testing of metallic materials at room temperature, with cemented carbides in an annex and elevated-temperature testing referred to Practice E209. Both are developed by Committee E28 (E28.04).
Bonded resistance strain gages and extensometers
Strain can be measured by gages bonded to the specimen or by an extensometer that tracks two gauge points. The two have separate documents. ASTM E251-20a, Test Methods for Performance Characteristics of Metallic Bonded Resistance Strain Gages, covers resistance at a reference temperature, gage factor, the temperature coefficient of gage factor, transverse sensitivity and thermal output. It is not for transducers such as load cells and extensometers. Most of its performance tests are destructive, so the results are statistical and apply to a production lot; individual gages cannot be calibrated this way, and resistance is the only nondestructive check that can be made on each gage.
ASTM E83-25, Standard Practice for Calibration, Verification, and Classification of Extensometer Systems, is active (last updated 19 June 2025, subcommittee E28.01). It covers procedures for calibrating, verifying and classifying extensometer systems and says it is not a complete purchase specification. It applies only to instruments that indicate or record values proportional to length changes from tensile or compressive strain, and classifies systems by the size of their strain measurement errors. Because strain is dimensionless, the practice can be used with extensometers that report displacement in SI or US customary units. Bonded resistance strain gages attached directly to a specimen are excluded from its verification apparatus; E251 is the document for those.
Digital image correlation
Digital image correlation (DIC) measures deformation from images of a specimen surface taken during a test. The International Digital Image Correlation Society (iDICs) publishes the Good Practices Guide for Digital Image Correlation, Edition 2 (2025), edited by E.M.C. Jones and M.A. Iadicola (DOI 10.32720/idics/gpg.ed2; Edition 1 appeared in 2018). Its stated focus is good practice for DIC measurement setup, image correlation and basic post-processing for strain computations, applied to mechanical testing of planar test pieces under common laboratory conditions. Edition 2 adds global DIC, more figures, examples and references. A working group that included commercial software representatives wrote it, a public comment period followed, and Executive Board members not involved in the writing approved the final version. The guide is positioned as a primer for new practitioners and as a reference and troubleshooting aid for experienced users.
What the standards imply for lab practice
Reading these documents side by side shows three habits that apply in any mechanical test lab.
- Report a value as belonging to a specimen, not a product. E8/E8M states that a specimen result may not represent the whole product, so a test report should identify the specimen, its position and the version of the standard used.
- Separate the sensor’s qualification from the test. E251 results are statistical and describe a gage lot, while E83 classifies an extensometer system by its strain error. Neither document is a substitute for the other, and each excludes the other’s device type.
- Record the measurement setup, not only the answer. The DIC guide centres on setup, correlation and post-processing because each stage can change the strain that is reported. A written standard operating procedure that names the document edition, units and room temperature range makes a result easier to repeat; see also reproducibility and electronic lab notebooks for recording it.
Where results feed an accredited testing service, laboratories often work under an accreditation body such as A2LA; the requirements that apply come from the accreditor, not from the test standards above.
Scope limits of each document
The table below sets out what each document says it does not cover, which is where labs most often reach for the wrong standard.
| Document | Does not cover or does not claim |
|---|---|
| ASTM E8/E8M-25 | Results from a specimen may not represent the whole product; powder metallurgy materials are treated separately; SI and inch-pound values are not exact equivalents |
| ASTM E9-19(2025) | Elevated-temperature compression testing, which is referred to Practice E209; cemented carbides are handled in Annex A1 |
| ASTM E251-20a | Transducers such as load cells and extensometers; calibration of individual gages through its destructive performance tests |
| ASTM E83-25 | A complete purchase specification; bonded resistance strain gages attached directly to a specimen |
| iDICs Good Practices Guide, Edition 2 | Complex test conditions beyond common laboratory conditions, and non-planar test pieces, which sit outside its stated focus on planar test pieces |
Related concepts: experimental versus analytical and computational mechanics
SEM’s stated role of providing verification for analytical and computational approaches defines the relationship. Analytical and computational methods predict behaviour from models; experimental methods measure it. Neither replaces the other: a model gives a prediction that a test can confirm or contradict, and a test gives a measurement whose meaning depends on the model and test conditions used to interpret it. Choosing which to use for a particular question is a matter for the investigator and the governing standard, not for a general rule.
Common misunderstandings
- “Experimental mechanics is the same as the journal.” Experimental Mechanics and Experimental Techniques are two separate SEM-listed journals; the field is wider than either.
- “A tension test describes the material.” E8/E8M describes a result for the specimen tested under stated conditions and notes it may not represent the whole product.
- “A calibrated gage is calibrated individually.” E251 states most of its tests are destructive and statistical, so individual gages cannot be calibrated by those methods.
- “One standard covers every strain sensor.” E83 covers extensometer systems and excludes bonded gages; E251 covers bonded gages and excludes transducers.
Frequently asked questions
What are mechanics of materials?
Mechanics of materials is the analytical study of how loaded materials and members deform and carry stress. Experimental mechanics supplies the measurements, such as the tension and compression results above, that analytical and computational approaches are checked against.
What are experimental techniques?
In this field, experimental techniques are the physical measurement methods listed above: tension and compression testing, bonded strain gages, extensometers and digital image correlation. Experimental Techniques is also the name of a bimonthly SEM journal.
Is fluid mechanics the hardest class?
There is no measured basis for ranking classes by difficulty; it depends on the student and the course, so any answer is an opinion rather than a fact. Fluid mechanics has its own experimental methods, outside the solid-mechanics standards covered here.
What are the experimental foundations of quantum mechanics?
That is a different field. Experimental mechanics in the SEM sense concerns the deformation and response of materials and structures, not quantum experiments, and this page does not cover quantum physics.
Sources
- Society for Experimental Mechanics, home and about pages, checked 2026-11-20
- ASTM E8/E8M-25, Standard Test Methods for Tension Testing of Metallic Materials, checked 2026-11-20
- ASTM E9-19(2025), Standard Test Methods of Compression Testing of Metallic Materials at Room Temperature, checked 2026-11-20
- ASTM E251-20a, Test Methods for Performance Characteristics of Metallic Bonded Resistance Strain Gages, checked 2026-11-20
- ASTM E83-25, Standard Practice for Calibration, Verification, and Classification of Extensometer Systems, checked 2026-11-20
- iDICs, Good Practices Guide for Digital Image Correlation, Edition 2 (2025), checked 2026-11-20
Data: Experimental mechanics measurement methods and the documents that govern them
Compiled from the ASTM store listings for E8/E8M-25, E9-19(2025), E251-20a and E83-25 and the iDICs Good Practices Guide landing page. Each row names a measurement method, what the document covers, its status and maintaining group as listed on the source page.
Period covered: 2020/2025.
| Method | What the document covers | Governing document | Status as listed | Maintaining group | Last updated or edition year |
|---|---|---|---|---|---|
| Tension testing | Yield strength, tensile strength, elongation, reduction of area | ASTM E8/E8M-25 | Active | E28.04 | 2025-08-26 |
| Compression testing | Axial-force compression behaviour of metallic materials at room temperature | ASTM E9-19(2025) | Version E0009-19R25E01 listed as Active | E28.04 | 2025-04-29 |
| Bonded resistance strain gages | Gage resistance, gage factor, temperature coefficient of gage factor, transverse sensitivity, thermal output | ASTM E251-20a | Active | E28.01 | 2020-08-07 |
| Extensometer systems | Calibration, verification and classification by strain measurement error | ASTM E83-25 | Active | E28.01 | 2025-06-19 |
| Digital image correlation | Setup, image correlation and basic post-processing for strain on planar test pieces | iDICs Good Practices Guide, Edition 2 | Edition 2 (2025) | iDICs working group | 2025 |
Sources
- ASTM E8/E8M-25 (accessed 2026-11-20)
- ASTM E9-19(2025) (accessed 2026-11-20)
- ASTM E251-20a (accessed 2026-11-20)
- ASTM E83-25 (accessed 2026-11-20)
- iDICs Good Practices Guide for DIC, Edition 2 (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.