Fall Mat: What It Does, the Evidence and the Trip Risk

What a fall mat does, what drop-test and observational studies found about injury risk and trip hazard, and how it differs from a bed exit alarm.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product and research information only; this is not medical advice and does not replace a facility’s own fall-prevention policy or clinical judgment.

Short answer

A fall mat is a cushioning mat placed on the floor beside a bed or chair so that a person who falls lands on a softer surface than bare flooring. In laboratory biomechanical tests it lowered the modelled risk of serious head injury, but a separate observational study found that a thick, bevel-edged bedside mat made some older patients stumble when they stepped onto it.

Definition and scope

This page uses “fall mat” for a passive impact-cushioning mat. It reduces how hard a body hits the floor; it does not stop a fall and does not tell anyone that a fall is happening. That separates it from a sensor or alarm mat, which signals staff when pressure changes and offers no cushioning. The related search phrases “fall prevention equipment” and “bed exit alarm” are covered below as neighbouring interventions, because a mat is only one item in that group.

How fall mats are used in practice

The studies on mats test them next to a bed, usually paired with a bed set at its lowest position. Bowers and colleagues (Rehabilitation Nursing, 2008) modelled head-first and feet-first falls from six bed heights onto tile and onto a floor mat. For a feet-first fall from a bed height of 97.5 cm onto tile, they estimated a 25% chance of serious head injury, and 40% when the added height of bedrails was included. With a floor mat, the estimate for bedrail height fell to less than 1% for feet-first falls. The authors paired floor mats with height-adjustable beds at their lowest position in their conclusion. This was biomechanical modelling, not a trial of patient outcomes.

Raymond and colleagues (Rehabilitation Nursing, 2011) dropped a side-impact test dummy from 45.7, 61.0 and 76.2 cm onto a rigid floor and onto two mat types. On the unpadded rigid floor the risk of serious head injury exceeded 50% at 61.0 and 76.2 cm. Both mats significantly reduced head and pelvis injury risk at every height tested, and thoracic risk for all but the highest drop.

For how mats fit into a wider programme, see the CASRAI guide to a hospital fall prevention program, and for the bed itself, what a hospital bed is.

The trade-off: injury protection versus trip risk

The same product can create a hazard. Doig and Morse (Journal of Patient Safety, 2010) video-recorded 15 participants, 10 of whom used a 1-inch-thick bevel-edged mat. The mat caused elderly participants to lose balance and, in some cases, stumble; 8 of the 10 had difficulty getting out of bed, because heels landing on the beveled edge shifted the centre of gravity backward. Walkers and mobile IV stands were also unbalanced on the mat. The authors called a bevel-edged bedside mat a potential hazard for ambulatory patients, especially those with impaired gaits, or those using walkers and pushing mobile IV stands.

Mat, bed exit alarm and low bed: what each addresses

Intervention What it addresses What the cited source says
Fall mat Severity of injury if a fall happens Lower modelled head-injury risk in drop tests (Bowers 2008; Raymond 2011); stumbling hazard for ambulatory patients (Doig and Morse 2010)
Bed or chair sensor alarm Notification that a person is leaving the bed or chair Cochrane review (2018): 2 trials, 28,649 participants; rate of falls ratio 0.60 (95% CI 0.27 to 1.34); very low-quality evidence, effect uncertain
Bed at lowest height Distance of the fall Bowers 2008 recommended it alongside floor mats

The alarm row concerns a different product. See what a bed alarm is and the chair alarm guide for how those devices work.

Where it matters for labs, clinics and supply decisions

A reader weighing a mat can turn the findings above into questions for their own setting. Each question traces to one study:

  • Does the mat have a raised or beveled edge, and do patients step across it? (Doig and Morse 2010)
  • Do patients who can walk use walkers or push IV stands next to the bed? (Doig and Morse 2010)
  • How high is the bed surface, including any bedrails? (Bowers 2008)
  • Is the mat being expected to alert staff? It cannot; that is the job of an alarm. (Cochrane 2018)

Evidence strength matters too. An integrative review by Pati and colleagues (Journal of Patient Safety, 2021) covered 30 articles from 1990 to 2017 and judged the evidence on design elements including floor mats not high enough for robust confidence in design decisions. Mats are also separate from restraint decisions; see medical restraints. Risk screening is compared in fall risk assessment tools compared.

Common misunderstandings

A fall mat is not an alarm

A cushioning mat gives no signal. A floor sensor mat is a different product that detects pressure and alerts staff.

A fall mat does not make a fall harmless

The cited tests report reduced injury risk, not zero risk, and they are laboratory models rather than patient outcome trials.

A mat is not automatically safe for everyone who walks

The stumbling findings apply to ambulatory patients with impaired gait and to walkers and IV stands.

FAQ

What is a fall mat?

A cushioning floor mat placed beside a bed or chair to soften the landing if someone falls.

Does a fall mat prevent falls?

No. In the cited studies it was tested for reducing injury risk once a fall occurs; the Doig and Morse study found it could add a trip hazard.

Is a fall mat the same as a bed exit alarm?

No. An alarm notifies staff; a mat cushions impact. The Cochrane review rated the evidence for sensor alarms as very low quality and uncertain.

How strong is the evidence?

Limited. The 2021 integrative review concluded that the evidence on floor mats and related design elements is not high enough for robust confidence.

Sources

  • Bowers B et al. Rehabilitation Nursing 2008;33(6):253-259. PubMed PMID 19024240 (checked 2026-11-01).
  • Raymond DE et al. Rehabilitation Nursing 2011;36(6):248-254. PubMed PMID 22073504 (checked 2026-11-01).
  • Doig AK, Morse JM. Journal of Patient Safety 2010;6(2):68-75. PubMed PMID 22130346 (checked 2026-11-01).
  • Pati D et al. Journal of Patient Safety 2021;17(4):273-281. PubMed PMID 31157738 (checked 2026-11-01).
  • Cameron ID et al. Cochrane Database of Systematic Reviews 2018. PubMed PMID 30191554 (checked 2026-11-01).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Fall Mat: What It Does, the Evidence and the Trip Risk

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →