Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
The HL7 FHIR QuestionnaireResponse resource (QuestionnaireResponse) is the standardized Fast Healthcare Interoperability Resources (FHIR) instance structure used to capture a completed or in-progress set of answers supplied by a patient, clinician, or caregiver in response to a structured form definition (HL7 FHIR Questionnaire). Across digital patient intake software, USCDI v3 Social Determinants of Health (SDOH) screenings, and clinical trial electronic Patient-Reported Outcomes (ePRO), QuestionnaireResponse provides a deterministic, auditable JSON payload linking every submitted answer back to its exact form prompt via linkId.
What Should Be Included in a FHIR QuestionnaireResponse?
Under the HL7 FHIR Release 4 specification (hl7.org/fhir/R4/questionnaireresponse.html) and the US Core QuestionnaireResponse Profile, a compliant QuestionnaireResponse payload includes both header metadata (who completed which form and when) and a recursive item[] tree containing the recorded answers:
| Element Path | Cardinality (R4 / US Core) | Data Type | Required Content & Validation Rules |
|---|---|---|---|
status |
1..1 / 1..1 |
code |
Mandatory lifecycle state: in-progress | completed | amended | entered-in-error | stopped. |
questionnaire |
0..1 / 1..1 (MS) |
canonical(Questionnaire) |
Versioned canonical URI of the source form definition (e.g., http://hl7.org/fhir/us/core/Questionnaire/prapare|6.1.0). |
subject |
0..1 / 1..1 (MS) |
Reference(Patient|...) |
Identifies the patient or research subject the answers describe (Patient/[id]). |
authored |
0..1 / 1..1 (MS) |
dateTime |
ISO 8601 timestamp (including time zone offset) when the answers were gathered and saved. |
author & source |
0..1 / 0..1 (MS) |
Reference(...) |
author identifies who recorded/typed the answers (e.g., Practitioner or Patient); source identifies who provided the information (e.g., Patient or RelatedPerson caregiver). |
item[].linkId |
1..1 / 1..1 |
string |
Mandatory pointer that must match the exact item.linkId string and structural hierarchy defined in the canonical Questionnaire. |
item[].answer[].value[x] |
0..* / 0..* |
Choice of 12 types | Typed response value: valueBoolean, valueDecimal, valueInteger, valueDate, valueDateTime, valueTime, valueString, valueUri, valueAttachment, valueCoding, valueQuantity, or valueReference. |
How Is a FHIR QuestionnaireResponse Structured in EHR Workflows?
When implementing HIPAA-compliant intake forms or clinical screening flowsheets in an EHR, developers must enforce two core structural rules defined in the FHIR specification:
- Invariant
qrs-1(Mutually Exclusive Direct Childitemvs.answer): The FHIR R4 invariantqrs-1((answer.exists() and item.exists()).not()) states that aQuestionnaireResponse.itemcannot have both direct childitem[]elements and directanswer[]elements at the same level.- If the item is a Section / Group (
type = groupin theQuestionnaire), its children are placed directly initem.item[]. - If the item is an Answered Question that has conditional sub-questions nested beneath that specific answer, the child sub-questions must be nested inside the answer object at
item.answer[].item[].
- If the item is a Section / Group (
- FHIRPath Extraction and Scoring: Downstream EHR engines and HL7 Structured Data Capture (SDC) pipelines use FHIRPath expressions (such as
QuestionnaireResponse.repeat(item).where(linkId='q1').answer.valueCoding) to extract discrete LOINC/SNOMED CT observations and calculate total instrument scores.
Reusable FHIR R4 QuestionnaireResponse JSON Template
The production-ready JSON template below demonstrates a valid USCoreQuestionnaireResponseProfile payload containing a section group (item.item), coded LOINC/SNOMED answers (valueCoding), numeric answers (valueInteger), and a nested conditional sub-question placed inside answer[].item[] in compliance with invariant qrs-1:
{
"resourceType": "QuestionnaireResponse",
"id": "sdoh-and-pain-intake-response-001",
"meta": {
"profile": [
"http://hl7.org/fhir/us/core/StructureDefinition/us-core-questionnaireresponse"
]
},
"questionnaire": "http://example.org/fhir/Questionnaire/ambulatory-intake-v2",
"status": "completed",
"subject": {
"reference": "Patient/example-patient-101",
"display": "Elena Rostova"
},
"encounter": {
"reference": "Encounter/ambulatory-visit-550"
},
"authored": "2026-11-09T15:20:00-05:00",
"author": {
"reference": "Patient/example-patient-101"
},
"source": {
"reference": "Patient/example-patient-101"
},
"item": [
{
"linkId": "section-sdoh-screening",
"text": "Social Determinants of Health (Hunger Vital Sign)",
"item": [
{
"linkId": "loinc-88122-7",
"text": "Within the past 12 months we worried whether our food would run out before we got money to buy more",
"answer": [
{
"valueCoding": {
"system": "http://loinc.org",
"code": "LA28397-0",
"display": "Often true"
}
}
]
}
]
},
{
"linkId": "section-clinical-symptoms",
"text": "Symptom Screening",
"item": [
{
"linkId": "current-pain-present",
"text": "Are you currently experiencing acute pain?",
"answer": [
{
"valueBoolean": true,
"item": [
{
"linkId": "pain-severity-nrs",
"text": "Pain severity on a 0 to 10 numeric rating scale",
"answer": [
{
"valueInteger": 7
}
]
}
]
}
]
}
]
}
]
}
Frequently Asked Questions
What should be included in a FHIR QuestionnaireResponse?
A compliant HL7 FHIR QuestionnaireResponse must include a lifecycle status (such as in-progress or completed), a canonical URI reference to the governing Questionnaire, the subject (Patient reference), the authored timestamp, author/source references, and a hierarchical item[] array where every item carries the exact linkId from the Questionnaire and stores typed answers inside answer[].value[x].
How is a FHIR QuestionnaireResponse structured in EHR workflows?
In EHR and US Core FHIR workflows, a QuestionnaireResponse mirrors the group and question nesting of its parent Questionnaire while obeying invariant qrs-1: group containers place child items in item.item[], whereas questions with conditional follow-ups nest their sub-questions inside item.answer[].item[] so Structured Data Capture ($extract) engines can convert answers into discrete FHIR Observation and Condition resources.