Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
Flexiseal (written by the manufacturer as Flexi-Seal) is a brand of indwelling fecal management systems made by Convatec. This page explains what the system is, what is in the kit, how the product variants differ and what the FDA record says about it. It is written for clinic staff, buyers and students who need a reference for the device class, not a clinical protocol.
Ask CASRAI · free to tryQuestion about this guide? Ask CASRAI answers with linked sources. 2 free questions a day, no account.
What is a fecal containment device (and what is Flexiseal used for)?
A fecal containment or fecal management device is an indwelling catheter that diverts liquid to semi-liquid stool into a closed collection bag. In its 510(k) clearance for the Flexi-Seal PROTECT PLUS Fecal Management System, FDA records the indications for use as an “indwelling fecal management catheter intended for use to manage fecal incontinence through the collection of liquid to semi-liquid stool and to provide access to administer medications. The device is intended for use in adult patients.”
So Flexiseal (also searched as “flexi seal”) is used to manage fecal incontinence by collecting liquid to semi-liquid stool, and the catheter has a port through which medications can be given. For the regulatory code map that covers this whole device group, and how it differs from a plain rectal tube, see Fecal Collector: FDA Product Codes, Class and Rectal Tube Difference.
How the Flexi-Seal system is built
The FDA 510(k) summary (K190114) and the manufacturer’s product page describe the PROTECT PLUS kit as follows.
- Catheter: silicone with zeolite, described in the FDA comparison table as an odor barrier catheter.
- Retention balloon: a low-profile retention balloon. Its fill is governed by the manufacturer’s instructions for use (IFU), which this page does not reproduce.
- Fill indicators: a green dome indicates the optimal fill status of the retention balloon, and a red dome warns of over-inflation (the manufacturer calls this the PROTECT over-inflation warning indicator).
- Port for irrigation and medication: the catheter has a port for medication and irrigation. On the PROTECT PLUS with the ENFit connector the port is self-closing and an ENFit syringe is included in the kit.
- Self-closing quick connector on the catheter end, with a matching bag connector.
- Collection bag: closes with a cap (not self-closing). The PROTECT PLUS kit includes Diamonds gelling and odor control sachets (4 per kit).
- Packaging: clamshell with a label card, the IFU and five date labels.
Flexi-Seal types and variants
Convatec’s Flexi-Seal range lists the Flexi-Seal PROTECT PLUS FMS, the PROTECT FMS, the SIGNAL FMS and the Flexi-Seal Fecal Collector. The table below covers the variants and the one competing system that FDA compared them with; every value comes from the K190114 comparison table or the Convatec product page.
| Feature | Flexi-Seal PROTECT PLUS (K190114) | Flexi-Seal PROTECT (K162906) | Bard DigniShield ENFit |
|---|---|---|---|
| Sterility | Non-sterile | Non-sterile | Non-sterile |
| Visual fill and over-inflation indicators | Yes | Yes | No |
| Catheter material | Silicone with zeolite | Silicone with zeolite | Thermoplastic elastomer and silicone |
| Irrigation and medication port | ENFit (ISO 80369-3), self-closing | Luer | ENFit (ISO 80369-3) |
| ENFit syringe in kit | Yes | No | No |
| Odor control | Diamonds gelling and odor control sachets | None listed | Odor eliminator spray |
On the Convatec product page the PROTECT PLUS kit with the ENFit connector is REF 421703 and the kit with the Luer connector is REF 422303; a Privacy collection bag with an APS filter (REF 422291, 5 per box) is listed for PROTECT PLUS only. ENFit is the ISO 80369-3 small-bore connector standard for enteral devices, and the Luer versus ENFit connector is the practical difference between kit versions.
Regulatory identity: what FDA clearance means here
The K190114 letter, dated April 30, 2019, lists the device under 21 CFR 876.5980 (Gastrointestinal Tube and Accessories), Regulatory Class II, product codes KNT and PIF, applicant ConvaTec Limited. FDA’s finding is “substantially equivalent” to a predicate (here the PROTECT system, K162906). That is clearance on equivalence, not FDA approval. The summary states that clinical testing was not required, and the new ENFit features were supported by bench testing such as connector joint strength and water leakage.
How long can Flexi-Seal stay in?
This page gives no dwell time. How long a catheter stays in for an individual patient is a clinical decision made by the treating clinicians under the current IFU for the specific product.
How to take out a Flexiseal, and how to empty the bag
Removal and bag emptying are performed or directed by clinicians following the current IFU for the specific product in the kit. This page does not give step-by-step instructions for either.
Common mistakes to avoid when reading product information
- Treating “FDA cleared” as “FDA approved.” Class II 510(k) clearance means substantial equivalence.
- Mixing up kit versions. The ENFit and Luer versions use different connectors, so the REF number matters.
- Assuming every fecal containment product shares one specification. The table above shows differences in indicators, connectors and materials even between products FDA compared.
Frequently asked questions
What is Flexiseal?
Flexi-Seal is Convatec’s brand of fecal management systems: indwelling catheters with a retention balloon and a closed collection bag, FDA product codes KNT and PIF, Class II.
What is a fecal containment device?
An indwelling catheter system that collects liquid to semi-liquid stool for adult patients with fecal incontinence, per the FDA indications for use quoted above.
What is Flexi-Seal used for?
Managing fecal incontinence by collecting liquid to semi-liquid stool, and providing access to administer medications (K190114 indications for use).
How long can Flexi-Seal stay in?
This page gives no dwell time; the IFU and the treating clinician decide for the individual patient.
How to take out a Flexiseal?
Clinicians perform or direct removal according to the product IFU; this page gives no removal steps.
Is Flexi-Seal the same as DigniShield?
No. DigniShield is Bard’s competing stool management system; FDA compared the two in K190114, with differences in material and indicators shown in the table above.
Sources
- U.S. FDA, 510(k) K190114 clearance letter and summary, Flexi-Seal PROTECT PLUS Fecal Management System (with ENFit connector), April 30, 2019: accessdata.fda.gov. Checked 2026-11-07.
- U.S. FDA 510(k) database record for K190114: accessdata.fda.gov. Checked 2026-11-07.
- Convatec, Flexi-Seal PROTECT PLUS FMS product page: flexi-seal.convatec.com. Checked 2026-11-07.
Related reading: Enema Kit Types and Clinical Use, What Is a Urinary Drainage Bag? and Adult Incontinence Product Selection Guide.