A fluid power system uses a pressurised fluid, either a liquid (hydraulics) or a gas (pneumatics), to generate, control and transmit power from a pump or compressor to an actuator that does the work. Because pressure acts equally in all directions in a confined fluid (Pascal’s law), a small force applied at one piston can be turned into a much larger force at another, and the same layout can push, pull, lift, clamp or rotate. This guide explains how the systems work, what each component does, how hydraulics and pneumatics differ, how to choose between them, and the stored-energy hazards that make safe handling the central practical concern.

What a fluid power system is and what it does

The National Fluid Power Association describes fluid power as a term covering hydraulics and pneumatics technologies, both of which use a fluid to transmit power from one location to another. The International Fluid Power Society gives the same idea in a sentence: the use of fluids under pressure to generate, control and transmit power. Hydraulics uses a liquid, usually oil though water is also used; pneumatics uses a gas, usually compressed air though nitrogen or other gases serve special applications.

The practical appeal is the combination of properties the trade bodies list. Cylinders give linear motion directly, with no need to convert rotary motion. High power can be transmitted in a small space, especially where high force or torque is needed. Direction, speed, force and torque are controlled by relatively simple valves. And many fluid power systems need no electrical power at the point of work, which removes the risks of electric shock, sparks, fire and explosion there. In research and laboratory settings you meet the same principles wherever a compressed-air line, a vacuum line, a pneumatic actuator or a hydraulic press is part of the equipment. If you handle supply gases, the compressed gas cylinder safety guide covers the cylinder side of the supply.

How fluid power works: Pascal’s law and F = P × A

Pascal’s law says that fluid pressure acts equally in all directions. The working relationship for a cylinder is force equals pressure multiplied by piston area (F = P × A). Pressure is set by the load the system is pushing against and limited by the pump or compressor and the relief arrangements; force then depends on how much piston area that pressure acts over.

A worked example

Take a cylinder with a piston area of 20 cm², which is 0.002 m². The figures below are an illustration of the arithmetic, not data for any product.

Case Pressure Area Force (F = P × A)
Hydraulic, 10 MPa (100 bar) 10,000,000 Pa 0.002 m² 20,000 N (20 kN)
Pneumatic, 1 MPa (10 bar) 1,000,000 Pa 0.002 m² 2,000 N (2 kN)
Pneumatic, 1 MPa, bore area ten times larger (200 cm²) 1,000,000 Pa 0.02 m² 20,000 N (20 kN)

The third row shows why pneumatic cylinders for heavy work need much larger bores. The British Fluid Power Association notes that hydraulic systems typically run at tens of MPa while pneumatic systems usually run at about 10 bar or less, so a pneumatic cylinder needs a considerably larger bore to produce the same force. The same source gives a second consequence of the formula: doubling a cylinder’s diameter quadruples its area, so the same load needs only a quarter of the pressure, but the piston then travels a quarter as far for the same fluid volume. Force can be multiplied, but never for free.

Components of a fluid power system

Both hydraulic and pneumatic circuits follow the same chain: something supplies pressurised fluid, conductors carry it, valves direct it, an actuator does the work, and support components keep the fluid in condition.

  1. Pumping device. A hydraulic pump, driven by a prime mover such as an electric motor, diesel or gas engine, or an air compressor.
  2. Fluid conductors. Tubing, hoses, fittings and manifolds that carry the fluid.
  3. Valves. They control flow, pressure, starting, stopping and direction, which is how actuator speed and movement are governed.
  4. Actuators. Cylinders for linear motion, motors and rotary actuators for rotation, plus grippers and vacuum cups.
  5. Support components. Accumulators, filters, heat exchangers and reservoirs in hydraulic systems; air receivers, filters, dryers and mufflers in pneumatic ones. Sensors and switches monitor pressure, temperature and flow.

Hydraulic fluid returns to a reservoir, forming a closed circuit. Pneumatic air is exhausted to the atmosphere after use, which is one reason pneumatic systems are generally simpler. A pneumatic compressor typically fills a receiver, and filters and air dryers clean the air before it reaches the control valves and actuators.

Hydraulics, pneumatics and vacuum compared

The two branches share principles but behave differently in practice. The data table below compares them using the attributes the National Fluid Power Association and the British Fluid Power Association publish.

When hydraulics is the better fit

Hydraulics suits heavy force and torque. The trade association lists off-highway equipment such as construction, mining, agriculture and utility machinery, heavy industrial equipment, and marine and offshore equipment as typical applications. Hydraulic systems are often described as rigid, because a liquid gives little cushioning, which supports steady, controlled movement under load. Components are generally steel or iron because of the pressures involved.

When pneumatics is the better fit

Pneumatics suits fast, repetitive pick-and-place work and gentler, controlled pressing or gripping. Applications named by the National Fluid Power Association include factory automation, medical and food processing equipment, chemical plants and refineries, and mobile equipment. Lower pressure allows lighter materials such as aluminium and engineered plastics, the air gives some cushioning, and pneumatic motors can stall without damage when overloaded, whereas an electric motor can overheat. Pneumatic equipment also does not need the bulky explosion-proof enclosures that electric motors often require.

Where vacuum fits

Vacuum is the third branch the trade association lists: suction cups lift objects by evacuating air, and the BFPA notes this can handle items as delicate as paper or eggs. It is used for lifting and moving workpieces and products.

How to choose between hydraulic and pneumatic systems

The deciding factors are force, speed, precision and the environment. Use the table as a first-pass screen and then confirm the specifics against the equipment manufacturer’s specifications and instructions for use (IFU).

If the application needs Lean towards Why (from the sources)
Very high force or torque in a small space Hydraulics Operates at tens of MPa; suited to heavy force and torque
Fast, repetitive motion of light loads Pneumatics Suited to pick-and-place and automation
Some cushioning or give Pneumatics Gas offers cushioning; hydraulics is rigid
Lifting by suction Vacuum Suction cups evacuate air to hold the object
Simple exhaust, no return line Pneumatics Air exhausts to atmosphere; oil returns to a reservoir
Lighter, lower-pressure components Pneumatics About 10 bar or less allows aluminium and engineered plastics

Whatever the choice, component selection has to respect the rated operating pressure of every part in the circuit, the compatibility of the fluid with seals and hoses, and the cleanliness the components need. Those limits come from the manufacturer’s documentation, not from general rules of thumb.

Safe use and handling of pressurised fluid systems

The hazard that defines fluid power is stored energy. OSHA’s hazardous energy guidance lists hydraulic and pneumatic energy among the energy sources in machines and equipment that can be hazardous, and warns that during servicing and maintenance the unexpected startup or release of stored energy can result in serious injury or death. The relevant US general-industry rule is 29 CFR 1910.147, the Control of Hazardous Energy (Lockout/Tagout) standard.

OSHA places responsibility for protecting workers on the employer and requires training. Under its training provisions:

  • Workers must learn the purpose and function of the energy control program and acquire the skills to apply, use and remove energy control devices.
  • Authorised employees must be trained to recognise hazardous energy sources, the type and magnitude of the energy present, and how to isolate or control it.
  • Employees in affected areas must understand the procedures, including the prohibition on restarting or re-energising locked or tagged-out equipment.
  • Employees must be retrained to keep their proficiency or when control methods change.

Practical consequences follow from the physics. A hydraulic or pneumatic circuit can hold pressure after the power source is stopped, so isolation alone does not make the system safe; the stored pressure has to be dealt with under the site’s written energy control procedure and the manufacturer’s instructions. Pressurised hoses and fittings are handled by trained personnel only, and a pressure rating is a limit, not a target. Controls are ranked in the hierarchy of controls: eliminate or substitute the hazard where possible, then engineer it out, and rely on procedures and protective equipment last. Pressurised gas supplies have their own checks; see the compressed gas cylinder inspection checklist.

Common mistakes

  • Treating a stopped system as a safe one. Stored pressure can remain until it is deliberately released through the approved procedure.
  • Exceeding rated pressure. Every hose, fitting, seal and actuator has a rating; the lowest-rated part sets the circuit’s limit.
  • Neglecting filtration. Filters and dryers exist to keep debris and moisture out of valves and actuators; skipping their maintenance shortens component life.
  • Mixing up the pressure ranges. A pneumatic part is not designed for hydraulic pressures, and sizing a pneumatic cylinder by hydraulic intuition under-delivers force by roughly the pressure ratio.
  • Ignoring the instructions for use. Operating limits, fluids and maintenance intervals are manufacturer-specific.

Frequently asked questions

What is the difference between hydraulics and pneumatics?

Hydraulics transmits power through a liquid, usually oil, at pressures typically in the tens of MPa. Pneumatics uses a gas, usually compressed air, at about 10 bar or less. Hydraulics suits heavy force and torque; pneumatics suits fast, lighter-duty, repetitive work.

What is Pascal’s law and why does it matter in fluid power?

Pascal’s law states that fluid pressure acts equally in all directions. It is why pressure generated at a pump can be delivered to a cylinder elsewhere in the circuit, where force equals pressure multiplied by piston area.

What are the main components of a fluid power system?

A pump or compressor to pressurise the fluid, conductors (tubing, hoses, fittings, manifolds), valves that control flow, pressure and direction, actuators such as cylinders and motors, and support parts such as reservoirs, filters, accumulators, receivers and dryers.

Why is stored energy dangerous in hydraulic and pneumatic systems?

OSHA lists hydraulic and pneumatic energy among hazardous energy sources and warns that the unexpected startup or release of stored energy can cause serious injury or death during servicing. Employers must have energy control procedures and train workers under 29 CFR 1910.147.

Do fluid power systems need electricity?

Many do not at the point of work. The National Fluid Power Association notes that fluid power often needs no electrical power there, which reduces the risk of shock, sparks, fire and explosions, although a pump or compressor still needs a prime mover.

Where does the working fluid go after use?

In hydraulic systems the fluid returns to a reservoir. In pneumatic systems the air is exhausted to the atmosphere, which makes them generally simpler.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Fluid Power Systems

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →