Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
A formic acid safety data sheet (SDS) details the physical hazards, toxicological profiles, occupational exposure thresholds, and handling safeguards for methanoic acid (CAS 64-18-6). In concentrated formulations (90% or greater), formic acid is classified under the Globally Harmonized System (GHS) as a Category 3 flammable liquid (H226), a Category 1 metal corrosive (H290), a Category 4 oral toxin (H302), a Category 3 inhalation toxin (H331), and a Category 1A skin corrosive (H314). Beyond immediate tissue destruction, formic acid presents a unique bench-level hazard: it slowly undergoes spontaneous unimolecular decarbonylation at room temperature, evolving carbon monoxide (CO) gas. This reaction builds severe internal pressure inside sealed glass or plastic containers, necessitating specialized vented caps, temperature-controlled storage, and strict segregation from oxidizing mineral acids like nitric acid.
Chemical identity and regulatory scope of formic acid
Formic acid, systematically designated as methanoic acid, is the simplest carboxylic acid, possessing the molecular formula HCOOH (chemical formula CH2O2) and a molecular weight of 46.03 g/mol. Identified internationally by Chemical Abstracts Service number CAS 64-18-6, European Community number EC 200-579-1, RTECS number LQ4900000, and UN transportation designation UN 1779 (DOT Guide 153), the chemical is widely used across academic, clinical, and industrial laboratories. Key applications include serving as an organic mobile phase additive in liquid chromatography-mass spectrometry (LC-MS) to promote positive-ion electrospray ionization, a biological deproteinization reagent, a rapid decalcifier for bone specimens in histology suites, and a reducing agent in synthetic organic chemistry.
When reviewing an SDS provided by chemical manufacturers such as MilliporeSigma (Sigma-Aldrich), Fisher Chemical (Thermo Fisher Scientific), or Carl Roth, researchers must interpret the document according to the standardized 16-section format mandated by the OSHA Hazard Communication Standard (29 CFR 1910.1200) and the United Nations Globally Harmonized System of Classification and Labelling of Chemicals (GHS). Understanding how to read a safety data sheet ensures that laboratory personnel look beyond generic product descriptions to locate compound-specific operational guidance in Section 2 (Hazards Identification), Section 7 (Handling and Storage), Section 8 (Exposure Controls/Personal Protection), Section 9 (Physical and Chemical Properties), Section 10 (Stability and Reactivity), and Section 13 (Disposal Considerations).
The operational risks of formic acid stem directly from its thermodynamic and physical constants. Pure anhydrous formic acid exhibits a normal boiling point of 100.8 °C (213.4 °F), a melting and freezing point of 8.3 °C (47.0 °F), a liquid density of 1.220 g/mL at 20 °C, and an ambient vapor pressure of 35 mmHg (4.6 kPa) at 20 °C. It is a moderately strong organic acid in aqueous environments, with an acid dissociation constant (formic acid pKa of 3.75 at 25 °C) that is ten-fold more acidic than acetic acid (pKa 4.76). This elevated acidity, combined with rapid volatility and membrane penetration, produces rapid, deep coagulative necrosis upon contact with living tissue.
Formic acid hazards and GHS classification by concentration
Under GHS criteria and the OSHA Hazard Communication Standard, concentrated formic acid (90% w/w or greater) carries the signal word DANGER and requires three primary GHS hazard pictograms on the container label: the Flame (GHS02), the Corrosion symbol (GHS05), and the Skull and Crossbones (GHS06). Manufacturer safety data sheets outline seven standardized hazard statements for analytical, ACS, and LC-MS reagent grades:
- H226: Flammable liquid and vapor (Physical hazard, Flammable Liquids Category 3).
- H290: May be corrosive to metals (Physical hazard, Corrosive to Metals Category 1).
- H302: Harmful if swallowed (Health hazard, Acute Toxicity Oral Category 4).
- H314: Causes severe skin burns and eye damage (Health hazard, Skin Corrosion/Irritation Category 1A).
- H318: Causes serious eye damage (Health hazard, Serious Eye Damage/Eye Irritation Category 1).
- H331: Toxic if inhaled (Health hazard, Acute Toxicity Inhalation Category 3).
- EUH071: Corrosive to the respiratory tract (Supplemental hazard statement under CLP).
Regulatory authorities, including the European Chemicals Agency (ECHA) under Table 3 of Annex VI to the CLP Regulation (Regulation EC 1272/2008), define legally binding Specific Concentration Limits (SCLs) for aqueous formic acid mixtures. Chemical hazard categories shift substantially across concentration brackets, demanding differentiated risk management at the bench:
Concentrated Tier (Concentration ≥ 90% w/w): Stock reagents such as 98% to 100% puriss p.a. or Optima LC-MS grades fall into this category. The material is classified as Skin Corrosion Category 1A (H314) and Flammable Liquid Category 3 (H226). Contact causes instantaneous, irreversible full-thickness skin necrosis, corneal destruction, and deep subcutaneous ulceration. The vapor rapidly destroys respiratory epithelium, precipitating severe chemical burns.
Intermediate Corrosive Tier (10% to under 90% w/w): Technical solutions, 85% industrial grades, and concentrated histology decalcifiers sit within this boundary. The flammability classification drops out of standard transport categories below approximately 85% aqueous dilution, but the corrosive health hazard remains severe under Skin Corrosion Category 1B (H314) and Serious Eye Damage Category 1 (H318). Exposure produces severe chemical burns within one to two minutes of dermal contact.
Irritant Tier (2% to under 10% w/w): Dilute bench reagents, specialized washing formulations, and decalcification baths are classified as Skin Irritation Category 2 (H315) and Eye Irritation Category 2 (H319). These solutions induce localized erythema, stinging, chemical dermatitis, and reversible conjunctival edema, but generally do not trigger immediate necrotic sloughing if washed promptly.
Sub-Threshold Preparations (Concentration under 2% w/w): Analytical working eluents, such as 0.1% v/v formic acid in water or organic solvents, do not trigger autonomous GHS corrosive or irritant classifications under Annex VI cutoffs. However, laboratory personnel must recognize that preparing these dilute mixtures requires measuring and pipetting pure stock acid, where full concentrated hazard protocols remain mandatory during the dilution phase.
Formic acid flash point and flammability parameters
A prevalent safety misconception in chemical research settings is treating formic acid solely as an inorganic mineral acid rather than a combustible organic solvent. Concentrated formic acid contains an oxidizable carbon center bonded to hydrogen, giving it distinct flammability characteristics. Manufacturers report a closed-cup flash point between 49.5 °C and 50.0 °C (121.1 °F to 122.0 °F), with open-cup determinations ranging from 48 °C to 69 °C depending on atmospheric pressure and residual hydration.
Under OSHA 29 CFR 1910.106 and NFPA 30 (Flammable and Combustible Liquids Code), concentrated formic acid (90% to 100%) is categorized as a Class II Combustible Liquid (defined as any liquid having a closed-cup flash point at or above 100 °F / 37.8 °C and below 140 °F / 60.0 °C). This regulatory status imposes specific operating conditions upon laboratory storage and processing:
- Autoignition Temperature: Formic acid vapor self-ignites in air at temperatures between 520 °C and 540 °C (968 °F to 1004 °F). While considerably higher than volatile hydrocarbons like diethyl ether or hexane, heated laboratory oil baths, hot plates without independent temperature cutoffs, or distillation heating mantles can exceed 520 °C, posing an ignition threat.
- Flammability Limits in Air: The Lower Explosive Limit (LEL) for formic acid vapor in ambient air is 18.0% by volume (with specialized high-temperature determinations reporting values between 10.0% and 14.0%). The Upper Explosive Limit (UEL) is 57.0% by volume. Although the high LEL requires substantial vapor accumulation to form an explosive atmosphere, heating concentrated acid inside an unventilated enclosure can rapidly achieve these concentrations.
- Firefighting Media and Tactics: In the event of a laboratory fire involving formic acid, extinguishing agents must be chosen to account for its water miscibility and high polarity. Suitable media include alcohol-resistant aqueous film-forming foam (AR-AFFF), dry chemical powder, carbon dioxide (CO2), or fine water spray/fog. Straight-stream high-pressure water jets must never be discharged directly into pools of burning formic acid, as the mechanical force scatters the burning, highly corrosive liquid across bench surfaces, generating flying droplets that inflict simultaneous thermal and acid burns.
- Hazardous Combustion Byproducts: Complete combustion of formic acid yields water and carbon dioxide. However, under oxygen-depleted fire conditions or rapid thermal decomposition, enormous volumes of toxic carbon monoxide (CO) gas are generated alongside dense, acidic aerosol clouds. Firefighters and emergency responders must wear full chemical-resistant turnout gear and NIOSH-approved positive-pressure self-contained breathing apparatus (SCBA).
Storage requirements, pressure build-up, and vented container protocols
Section 7 and Section 10 of a compliant formic acid SDS describe a physical decomposition hazard that is nearly unique among standard laboratory acids: continuous room-temperature unimolecular decarbonylation. Concentrated formic acid decomposes spontaneously according to the following stoichiometric reaction:
HCOOH → CO (gas) + H2O (liquid)
This unimolecular decomposition occurs continuously in bottled stock. The reaction rate is accelerated by warmth (ambient temperatures above 20 °C), exposure to direct natural sunlight, trace transition metal ions (such as iron or copper from contaminated pipettes), and high chemical purity (98% or greater). Because carbon monoxide is a non-condensable gas with very low aqueous solubility, the evolution of CO molecules inside a sealed, rigid glass or high-density plastic container causes a relentless increase in internal pneumatic pressure.
Unvented storage of concentrated formic acid creates catastrophic explosion risks. Chemical safety boards, institutional biosafety officers, and university EHS bulletins document frequent incidents where long-stored bottles of 98% to 100% formic acid violently exploded on laboratory shelves. In these events, accumulated pressure shattered heavy glass reagent bottles, projecting razor-sharp glass shrapnel across the room and dispersing liters of concentrated acid into adjoining cabinets. In other documented accidents, laboratory technicians attempted to uncap an aged bottle; as the threads were loosened, the cap violently sheared off like a projectile, propelling a concentrated aerosol burst into the worker’s face, neck, and upper chest.
To eliminate pressure-induced ruptures and catastrophic chemical releases, laboratory operating procedures must enforce five non-negotiable storage controls:
- Mandatory Vented Closures: Primary chemical suppliers (such as Sigma-Aldrich and Thermo Fisher Scientific) package concentrated analytical-grade formic acid in specialized containers fitted with breathable, vented caps. These caps incorporate a microporous polytetrafluoroethylene (PTFE) hydrophobic membrane or an elastomeric pressure-relief valve. The membrane permits evolving carbon monoxide gas to vent continuously into the storage cabinet while preventing liquid leakage and barring atmospheric water vapor from entering the bottle. Laboratory workers must never discard a factory-installed vented cap or replace it with a solid, airtight screw closure.
- Scheduled Manual Pressure Relief: If stock containers lack automatic venting membranes, laboratory standard operating procedures must mandate bi-weekly or monthly manual pressure relief. Personnel must transport the bottle into a certified chemical fume hood, point the neck away from their body and colleagues, wear full facial protection, and slowly loosen the cap until an audible gas hiss confirms pressure equalization, then retighten the cap snugly.
- Temperature Control Above the Freezing Point: Formic acid must be stored in a cool, well-ventilated corrosives cabinet maintained between 15 °C and 25 °C. Crucially, concentrated formic acid must never be placed into a cold room, walk-in cooler, or laboratory refrigerator operating below 8 °C. Pure formic acid freezes at 8.3 °C (47.0 °F). Liquid-to-solid freezing causes contraction followed by irregular crystal lattice expansion upon re-warming; this thermal cycle induces severe mechanical micro-fracturing in glass containers. When coupled with ongoing carbon monoxide evolution, thawed bottles suffer catastrophic structural failure.
- Strict Chemical Segregation: As an organic carboxylic acid and a combustible liquid, formic acid must be housed in dedicated organic acid or corrosive storage cabinets equipped with chemical-resistant secondary containment trays (e.g., HDPE). It must be strictly segregated from mineral oxidizing acids. Storing formic acid on the same shelf as nitric acid, perchloric acid, chromic acid, or concentrated hydrogen peroxide is a severe violation of chemical hygiene protocols.
- Active Inventory Management and Expiration Audits: Research groups should purchase formic acid in modest unit sizes (e.g., 500 mL or 1 L bottles) sized to near-term experimental needs rather than maintaining bulk multi-year reserves. Containers older than one year should be inspected by EHS officers for container bulging, cap embrittlement, or discoloration and promptly retired to hazardous waste.
Exposure limits, engineering controls, and personal protective equipment
Because formic acid has an elevated vapor pressure (35 mmHg at 20 °C), open-dish pouring, dispensing, or unattended beakers generate airborne vapor concentrations that exceed legal exposure limits within minutes. Section 8 of the SDS sets forth the mandatory airborne occupational exposure limits (OELs) established by regulatory and professional bodies:
- OSHA PEL (Permissible Exposure Limit): 5 ppm (9 mg/m³) as an 8-hour time-weighted average (TWA) under 29 CFR 1910.1000 Table Z-1. Compliance with this threshold is enforceable by law in all general industry workplaces across the United States.
- NIOSH REL (Recommended Exposure Limit): 5 ppm (9 mg/m³) as a TWA for up to a 10-hour workday within a 40-hour workweek.
- ACGIH TLV (Threshold Limit Value): 5 ppm as an 8-hour TWA, paired with a 15-minute Short-Term Exposure Limit (STEL) of 10 ppm (19 mg/m³). The STEL ensures that brief peak exposures during container decanting do not compromise respiratory mucosa.
- NIOSH IDLH (Immediately Dangerous to Life or Health): 30 ppm. Exposure at or above 30 ppm represents an acute life hazard capable of causing severe laryngeal spasm, acute pulmonary edema, irreversible eye injury, or fatal pulmonary hemorrhage.
Primary exposure routes include vapor inhalation, cutaneous absorption, ocular contact, and inadvertent oral ingestion. Target organs comprise the eyes, skin, nasal mucosa, pharynx, and upper respiratory tract. Inhalation of vapors at concentrations exceeding 5 ppm causes intense burning sensations, lacrimation, rhinorrhea, coughing, chest tightness, and dyspnea. Direct skin contact produces rapid, full-thickness chemical burns characterized by whitish or gray coagulated tissue that slowly sloughs off, often leaving deep, painful, slow-healing lesions.
Engineering controls serve as the primary defensive barrier against exposure. Concentrated formic acid must always be handled inside a certified chemical fume hood with a certified average face velocity between 80 and 120 feet per minute (fpm). Open-bench manipulation, heating on open hotplates, or vortexing without secondary containment is prohibited. Where automated synthesis or large-scale dispensing units operate, local exhaust sniffers and corrosion-proof ductwork must be verified periodically.
Personal Protective Equipment (PPE) selection requires careful scrutiny of polymer chemical degradation and permeation breakthrough data. Standard laboratory disposable gloves do not offer universal chemical resistance against low-molecular-weight organic acids:
Glove Selection: Heavy butyl rubber gloves (minimum thickness 0.5 mm / 20 mil) provide superior protection against concentrated formic acid (85% or greater), exhibiting ASTM F739 permeation breakthrough times exceeding 480 minutes (Class 6 protection). Neoprene gloves offer good intermediate resistance, with breakthrough times typically recorded between 60 and 75 minutes. In contrast, standard thin disposable nitrile gloves (4 to 8 mil) offer poor resistance; concentrated formic acid permeates thin nitrile within 15 to 30 minutes. Thin nitrile gloves are permissible solely for incidental, low-volume splash protection during micro-pipetting. If a drop of concentrated formic acid contacts a nitrile glove, the researcher must immediately peel off the gloves, wash hands thoroughly with soap and running water, and don a clean pair.
Eye and Face Protection: Splash goggles meeting ANSI Z87.1 specifications (equipped with indirect ventilation baffles to block chemical aerosol entry) must be worn whenever handling formic acid. When dispensing volumes greater than 500 mL, pouring from Winchester bottles, or conducting pressure-relief venting, a full-length chemical face shield (minimum 8 inches in height) must be secured over the splash goggles to safeguard the forehead, cheeks, and neck.
Respiratory Protection: If local engineering controls undergo maintenance, during emergency spill responses, or when airborne concentrations cannot be engineered below 5 ppm, workers must don a NIOSH-approved full-face air-purifying respirator equipped with combination organic vapor and acid gas (OV/AG) chemical cartridges and P100 particulate filters. For emergency operations in confined spaces or where vapor concentrations reach or exceed the 30 ppm IDLH threshold, positive-pressure supplied-air respirators (SAR) or self-contained breathing apparatus (SCBA) are legally required.
Accidental release, spill neutralization, and hazardous waste disposal
Section 6 and Section 13 of the SDS prescribe strict environmental and procedural controls for managing chemical releases and hazardous waste accumulation. Because formic acid combines severe corrosivity, volatile toxic vapors, and flammability, spill remediation demands disciplined execution.
For minor benchtop releases (volumes under 100 mL), the responding technician must immediately alert nearby researchers, confirm the chemical fume hood sash is properly adjusted, and don appropriate PPE, including butyl rubber gloves, chemical splash goggles, and an acid-resistant apron. The spill should be neutralized by slowly applying a basic inorganic salt such as sodium carbonate (Na2CO3) or sodium bicarbonate (NaHCO3).
Personnel must exercise extreme caution during chemical neutralization. The neutralization of formic acid with carbonate bases is strongly exothermic and releases substantial volumes of carbon dioxide gas:
2 HCOOH + Na2CO3 → 2 HCOONa + CO2 ↑ + H2O
Rapid addition of dry basic powders to pooled concentrated acid produces violent effervescence, splashing corrosive acid droplets onto surrounding equipment. Neutralizer must be added gradually from the outer perimeter of the spill inward toward the center until gas evolution completely subsides. The neutralized mixture should be tested with broad-range pH test paper to confirm a neutral pH between 6.0 and 8.0, absorbed with an inert inorganic medium such as vermiculite or diatomaceous earth, and collected in a heavy-duty polyethylene disposal container. Combustible cellulose materials (such as paper towels, rags, or sawdust) must never be applied to concentrated acid spills due to the risk of chemical heating and smoldering ignition.
In analytical chromatography laboratories, formic acid is routinely combined with polar organic solvents such as methanol or acetonitrile in reverse-phase mobile phases or during ion pairing chromatography. Waste management for these effluents requires strict segregation. Formic acid-containing wastes must be collected in dedicated, clearly designated polyethylene waste carboys labeled as non-halogenated organic acid mixtures. The collection carboy must be fitted with an exhaust venting cap or vapor trap to prevent carbon monoxide pressure accumulation during weeks of routine laboratory collection.
Under no circumstances should formic acid waste be co-mingled with oxidizing mineral acids. Inadvertently mixing formic acid into waste carboys containing nitric acid triggers a catastrophic, delayed oxidation-reduction explosion that shatters waste vessels and generates toxic, reddish-brown nitrogen dioxide (NO2) gas clouds. Similarly, mixing formic acid with concentrated sulfuric acid results in immediate dehydrative decomposition and explosive carbon monoxide release. In workflows employing alternative acidic modifiers such as trifluoroacetic acid, waste streams must be strictly segregated according to halogenated versus non-halogenated environmental categories in compliance with EPA Resource Conservation and Recovery Act (RCRA) regulations.
Common handling mistakes and laboratory safety checks
Safety audits, insurance reviews, and university laboratory incident reports reveal recurring errors in bench-level management of formic acid. Environmental Health and Safety (EHS) officers, laboratory managers, and principal investigators should verify that standard operating procedures prevent the following five high-risk practices:
| Unsafe Laboratory Practice | Associated Mechanism and Hazard | Corrective Safety Protocol |
|---|---|---|
| Replacing vented caps with solid caps | Spontaneous decarbonylation produces carbon monoxide gas, causing severe internal pressure buildup and explosive bottle rupture. | Retain factory PTFE membrane vented caps; inspect membrane integrity during monthly inventory audits. |
| Storing in cold rooms at 4 °C | Freezes at 8.3 °C (47 °F); thermal expansion and crystal stress upon thawing weakens glass, precipitating catastrophic failure. | Store exclusively between 15 °C and 25 °C in a cool, dark, dedicated flammable-corrosive acid cabinet. |
| Co-storing or co-disposing with nitric acid | Violent exothermic redox reaction generates immediate or delayed vessel explosions and toxic NO2 gas plumes. | Strictly segregate organic acids from inorganic oxidizers in independent secondary containment tubs and waste streams. |
| Using thin nitrile gloves for bulk handling | Rapid permeation breakthrough (under 15 to 30 minutes) causes undetected chemical exposure, dermatitis, and severe skin burns. | Mandate heavy butyl rubber gloves (exceeding 480 minutes breakthrough) for transfers; restrict nitrile to incidental splash defense only. |
| Neutralizing spills with paper towels or sawdust | Cellulose materials act as combustible fuel and accelerate exothermic decomposition, risking benchtop ignition. | Neutralize first with sodium bicarbonate slurry; absorb neutralized liquid exclusively with inert vermiculite or acid spill pads. |
The data table below compiles physical safety specifications, GHS classifications, flash points, and container requirements across common laboratory grades and preparations of formic acid.
Frequently asked questions
What are the primary GHS hazards listed on a formic acid SDS?
On an SDS for concentrated formic acid (90% or greater), the primary GHS classifications are Flammable Liquid Category 3 (H226), Corrosive to Metals Category 1 (H290), Acute Toxicity Category 4 Oral (H302), Acute Toxicity Category 3 Inhalation (H331), and Skin Corrosion Category 1A (H314). The signal word is DANGER, and the label displays the Flame, Corrosion, and Skull and Crossbones pictograms.
What is the flash point of formic acid?
The closed-cup flash point of concentrated formic acid (90% to 100%) is between 49.5 °C and 50.0 °C (121.1 °F to 122.0 °F). Under OSHA and NFPA standards, it is classified as a Class II Combustible Liquid, meaning it must be stored and dispensed away from ignition sources, hot surfaces, and open flames.
Why do formic acid storage bottles build up pressure?
Formic acid undergoes a slow, spontaneous decomposition reaction at room temperature known as decarbonylation (HCOOH → CO + H2O), producing carbon monoxide gas and water. In tightly sealed containers, the generated carbon monoxide cannot escape, causing dangerous internal gas pressure that can rupture glass or plastic bottles unless vented caps are used.
Which gloves provide adequate protection against concentrated formic acid?
Heavy butyl rubber gloves provide the highest level of protection, with chemical permeation breakthrough times exceeding 480 minutes (ASTM F739 Class 6). Neoprene provides intermediate resistance (60 to 75 minutes). Standard thin disposable nitrile gloves provide poor resistance (breakthrough in 15 to 30 minutes) and should only be used for incidental splash protection, never for sustained immersion or handling.
What are the OSHA PEL and NIOSH REL exposure limits for formic acid?
Both the OSHA Permissible Exposure Limit (PEL) and the NIOSH Recommended Exposure Limit (REL) for formic acid are 5 ppm (9 mg/m³) as a time-weighted average (TWA). ACGIH establishes a TLV-TWA of 5 ppm with a 15-minute Short-Term Exposure Limit (STEL) of 10 ppm. NIOSH designates 30 ppm as Immediately Dangerous to Life or Health (IDLH).
How should waste formic acid be neutralized and disposed of?
Formic acid spills or small waste residues should be neutralized slowly with a dilute basic salt such as sodium bicarbonate or sodium carbonate, applying powder from the perimeter inward until effervescence ceases and the pH reaches 6.0 to 8.0. Large waste volumes must be collected in dedicated, clearly labeled polyethylene containers fitted with vented caps and disposed of as hazardous non-halogenated organic acid waste.
Can formic acid be stored together with nitric acid or sulfuric acid?
No. Formic acid must never be stored with or mixed into waste streams containing nitric acid or concentrated sulfuric acid. Nitric acid is a powerful inorganic oxidizer that reacts violently with organic formic acid, triggering rapid redox gas explosions. Concentrated sulfuric acid dehydrates formic acid, causing rapid exothermic evolution of toxic carbon monoxide gas.
Sources
- NIOSH Pocket Guide to Chemical Hazards: Formic Acid. Centers for Disease Control and Prevention / National Institute for Occupational Safety and Health. https://www.cdc.gov/niosh/npg/npgd0296.html (Accessed 2026-11-15).
- OSHA Occupational Safety and Health Standards: Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000). Occupational Safety and Health Administration. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1000TABLEZ1 (Accessed 2026-11-15).
- European Chemicals Agency (ECHA): CLP Regulation Annex VI Table 3 Harmonised Classification and Specific Concentration Limits for Formic Acid (Index 607-001-00-0). https://echa.europa.eu/information-on-chemicals/cl-inventory-database/-/discli/details/57999 (Accessed 2026-11-15).
- Sigma-Aldrich Safety Data Sheet: Formic Acid puriss. p.a., ACS reagent (Product 33015). MilliporeSigma. https://www.sigmaaldrich.com/US/en/sds/sigald/33015 (Accessed 2026-11-15).
- Fisher Chemical Safety Data Sheet: Formic Acid, Optima LC/MS Grade (Product A117). Thermo Fisher Scientific. https://www.fishersci.com/store/msds?partNumber=A11750 (Accessed 2026-11-15).
- Chemical Hygiene and Personal Protective Equipment Selection Guide: Chemical Resistance Matrix. Lawrence Berkeley National Laboratory (LBNL). https://ehs.lbl.gov/resource/documents/chemical-hygiene/ (Accessed 2026-11-15).
Data: Formic Acid Grade and Concentration Safety Specifications
Laboratory specifications, GHS classifications, physical safety thresholds, and packaging standards across analytical and technical formic acid grades, compiled from manufacturer SDS and regulatory documentation.
Period covered: 2024/2026. Coverage: Global.
| Grade or Preparation | Formic Acid Purity (% w/w) | Flash Point Closed Cup (°C) | Skin Hazard Classification | Vented Cap Required | Primary Application |
|---|---|---|---|---|---|
| Optima LC/MS Grade (Fisher Chemical A117) | 99 | 50 | Skin Corr. 1A (H314) | Yes | Ultra-trace LC-MS mobile phase additive |
| ACS Reagent Grade (Sigma-Aldrich 33015) | 98 | 49.5 | Skin Corr. 1A (H314) | Yes | Organic synthesis and general analytical chemistry |
| Technical Concentrated Solution | 85 | 65 | Skin Corr. 1B (H314) | Recommended | Industrial processing and chemical synthesis |
| Histology Decalcification Solution | 10 | Skin Corr. 1B (H314) | No | Bone and mineralized tissue decalcification | |
| Bench Cleaning and Deproteinization Wash | 5 | Skin Irrit. 2 (H315) | No | Laboratory surface and equipment sanitization | |
| Standard LC-MS Mobile Phase Eluent | 0.1 | Not Classified | No | Reverse-phase chromatographic separation buffer |
Sources
- Sigma-Aldrich Safety Data Sheet: Formic Acid ≥98% (accessed 2026-11-15)
- Fisher Chemical Safety Data Sheet: Formic Acid Optima LC/MS (accessed 2026-11-15)
- ECHA CLP Annex VI Table 3: Formic Acid Specific Concentration Limits (accessed 2026-11-15)
- NIOSH Pocket Guide to Chemical Hazards: Formic Acid (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.