Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
Short answer
The density of pure glycerol is 1.2613 g/cm³ at 20 °C (relative density 1.26 vs. water). It is a clear, viscous, hygroscopic triol with a normal boiling point of 290 °C (decomposing at 760 mmHg), a melting point of 18.1 °C, and a dynamic viscosity of 954 cP at 25 °C.
Definition and scope
Glycerol (propane-1,2,3-triol; CAS RN 56-81-5; C3H8O3; MW 92.09 g/mol) is a trivalent sugar alcohol. Pure glycerol designates the chemical compound; commercial glycerin denotes grades containing 95% to 99.5% glycerol with residual moisture.
Glycerol Polarity and Molecular Structure
Glycerol features a three-carbon backbone with a hydroxyl group (-OH) on each carbon, establishing high glycerol polarity. Hydrogen bonding produces high cohesive energy, high boiling points, and hygroscopicity.
Glycerol Density and Glycerol Refractive Index
The standard baseline for glycerol density is 1.2613 g/cm³ at 20 °C (anhydrous 1.2653 g/cm³; USP grade requires ≥1.249 g/cm³ at 25 °C/25 °C). Because glycerol is 26% denser than water, unmixed additions sink rapidly in aqueous solutions.
The measured glycerol refractive index is n_D^20 = 1.4746 at 20 °C (sodium D line). Approaching optical glass (n ≈ 1.515), it serves as an optical clearing agent and mounting medium, minimizing spherical aberrations.
How it works or how it is used in practice
Bench protocols rely on verified physical constants to control separation, reaction kinetics, and thermal stabilization, using data from NIST Chemistry WebBook SRD 69, PubChem CID 753, and ILO-WHO ICSC 0624.
Glycerol Boiling Point and Glycerol Vapor Pressure
At 760 mmHg, the normal glycerol boiling point is 290 °C, where decomposition into acrolein occurs, preventing atmospheric distillation.
Glycerol vapor pressure is negligible at 1.68 × 10⁻⁴ mmHg (0.01 Pa) at 25 °C; open solutions do not evaporate. Vacuum distillation boils smoothly: 182.2 °C at 20 mmHg, 167.2 °C at 10 mmHg, 153.8 °C at 5 mmHg, and 125.5 °C at 1.0 mmHg.
Glycerol Viscosity and Bench Fluidics
Neat glycerol viscosity is 954 cP at 25 °C and 1412 cP at 20 °C (~1,000 times water at 1.002 cP). This creates drag in pipette tips. Dilution reduces viscosity non-linearly: 70% w/w drops to 17 cP at 25 °C, while 50% v/v measures 6 to 8 cP.
Glycerol Freezing Point and Supercooling
The thermodynamic glycerol freezing point is 18.1 °C to 18.2 °C. However, neat glycerol rarely solidifies in refrigerators because hydrogen bonding creates a kinetic barrier, supercooling into an amorphous glassy liquid unless seeded.
Glycerol Dielectric Constant and Glycerol pKa
The static glycerol dielectric constant is 42.5 at 25 °C, dissolving salts and polar co-solvents.
The aqueous glycerol pKa is 14.4 at 25 °C (IUPAC Serjeant and Dempsey dataset). As an extremely weak acid, glycerol remains un-ionized and neutral across biological buffer ranges (pH 4.0 to 9.5), causing zero pH drift.
Types or related concepts
Glycerol is a trihydric polyol. Bench scientists frequently compare its properties against related laboratory solvents. Values in the table below reflect experimental measurements from PubChem, NIST, and IUPAC datasets.
| Solvent / Compound | CAS Registry Number | Density at 20 °C (g/cm³) | Boiling Point at 1 atm (°C) | Melting / Freezing Point (°C) | Dynamic Viscosity at 20–25 °C (cP) | Dielectric Constant (25 °C) | Vapor Pressure at 25 °C (mmHg) |
|---|---|---|---|---|---|---|---|
| Glycerol | 56-81-5 | 1.2613 | 290 (decomp.) | 18.1 | 954 (25 °C) | 42.5 | 1.68 × 10⁻⁴ |
| Water | 7732-18-5 | 0.9982 | 100.0 | 0.0 | 1.002 (20 °C) | 78.4 | 23.8 |
| Ethylene Glycol | 107-21-1 | 1.1132 | 197.3 | -12.9 | 16.1 (25 °C) | 37.7 | 0.06 |
| Propylene Glycol | 57-55-6 | 1.0361 | 188.2 | -59.0 | 48.6 (25 °C) | 32.0 | 0.13 |
| Dimethyl Sulfoxide (DMSO) | 67-68-5 | 1.1004 | 189.0 | 18.5 | 1.99 (25 °C) | 46.7 | 0.42 |
Where it matters for labs, clinics or supply decisions
Understanding glycerol’s physical constants directly informs protocol execution, volumetric accuracy, and reagent storage across common laboratory workflows:
- Pipetting Accuracy: Concentrated glycerol causes 5% to 15% under-delivery in air-displacement pipettes due to wall adhesion. Volumetric accuracy requires positive-displacement pipettes, reverse pipetting, or using a calibrated transfer pipette for macro volumes.
- Density-Gradient Stabilization: Glycerol’s density of 1.2613 g/cm³ allows it to act as an effective weighting agent. Formulated into SDS-PAGE sample loading buffers at 10% to 20% v/v, it ensures samples sink into submerged gel wells without dispersion. In rate-zonal ultracentrifugation, glycerol gradients separate macromolecular complexes.
- Freeze Protection: Glycerol disrupts ice crystal lattices that cause cell lysis during freezing, serving as an additive in cryopreservation media formulations. For purified enzymes, incorporating 50% v/v glycerol into Tris-HCl enzyme storage buffers prevents ice formation at -20 °C, eliminating freeze-thaw denaturation.
- Solvent Stripping Limitations: Rotary evaporators cannot remove glycerol because it boils at 290 °C with negligible vapor pressure. Stripping requires deep vacuum from a rotary vane vacuum pump below 0.1 mmHg and heating above 120 °C. Biological workflows use dialysis or ultrafiltration instead.
Common misunderstandings
Glycerol Freezing Point at Room Temperature
Although datasheets list the glycerol freezing point as 18.1 °C, stock bottles at 18 °C do not freeze solid. High-purity glycerol supercools extensively and remains liquid due to kinetic barriers to crystal nucleation.
Evaporating Glycerol on a Standard Rotovap
Attempting to evaporate glycerol on a standard rotovap fails. Diaphragm pumps pulling 10 to 20 mbar cannot vaporize glycerol without temperatures past 180 °C, risking decomposition. Dialysis or diafiltration should be used instead.
Pipetting Glycerol with Standard Air-Displacement Pipettes
Forward pipetting of glycerol introduces air voids and leaves heavy liquid films inside the tip. Viscous solutions require reverse pipetting or positive-displacement tips with slow plunger movement.
Glycerol Polarity Index in HPLC Elution
Glycerol is absent from standard Snyder solvent polarity index (P’) tables not because it lacks polarity, but because its extreme viscosity (954 cP) creates prohibitive backpressures, making neat glycerol unusable as an HPLC mobile phase modifier.
Frequently asked questions
What is the exact density of pure glycerol at 20 °C?
Pure anhydrous glycerol has a density of 1.2613 g/cm³ at 20 °C (relative density 1.26 vs. water). USP-grade glycerin ranges from 1.249 to 1.261 g/cm³ based on moisture content.
What is the boiling point of glycerol at atmospheric pressure?
At 1 atmosphere (760 mmHg), the glycerol boiling point is 290 °C with thermal decomposition. Vacuum distillation is performed at reduced temperatures, such as 182.2 °C at 20 mmHg or 125.5 °C at 1.0 mmHg.
Why is glycerol difficult to pipette accurately in the lab?
Glycerol viscosity is 954 cP at 25 °C—roughly 1,000 times that of water. Air-displacement pipettes suffer from wall cling and air-cushion expansion. Reverse pipetting or positive-displacement tips eliminate these volumetric errors.
Does pure glycerol freeze solid at normal room temperature?
Although its melting point is 18.1 °C, pure glycerol supercools readily and remains liquid at room temperature and at 0 °C without deliberate crystal seeding.
What is the pKa of glycerol in aqueous solutions?
The aqueous glycerol pKa is 14.4 at 25 °C. Acting as an extremely weak acid, glycerol remains completely un-ionized and neutral across biological buffer ranges (pH 4.0 to 9.5).
Sources
- National Center for Biotechnology Information (NCBI). PubChem Compound Summary for CID 753, Glycerol. https://pubchem.ncbi.nlm.nih.gov/compound/753 (Accessed 2026-11-09).
- National Institute of Standards and Technology (NIST). Chemistry WebBook, SRD 69: Glycerol (CAS RN 56-81-5). https://webbook.nist.gov/cgi/cbook.cgi?ID=C56815&Units=SI (Accessed 2026-11-09).
- International Labour Organization / World Health Organization (ILO-WHO). International Chemical Safety Card (ICSC) 0624: Glycerol. https://chemicalsafety.ilo.org/dyn/icsc/showcard.display?p_card_id=0624 (Accessed 2026-11-09).
- Serjeant EP, Dempsey B. Ionisation Constants of Organic Acids in Aqueous Solution. IUPAC Chemical Data Series No. 23. Pergamon Press, 1979 (Accessed via PubChem 2026-11-09).