Skip to main content
v2026.11,986 entries · CC-BY 4.0

H250 Hazard Statement: Catches Fire Spontaneously in Air

H250 is the GHS hazard statement for pyrophoric liquids and solids. See its criteria, pictogram and the P-codes that two sources list for it.

Written and maintained by CASRAI Editorial Board

Published

On this page

H250 is the GHS hazard statement “Catches fire spontaneously if exposed to air.” It is assigned to pyrophoric liquids and pyrophoric solids in Category 1, the only category in either class, and it appears on labels and safety data sheets with the Flame pictogram (GHS02) and the signal word “Danger.” If you reached this page looking for a Krohne flowmeter or a pool-heater model number, this is a different “H250”: the chemical-labelling code.

Definition and scope

A hazard statement is the fixed sentence a GHS label carries for a given hazard class and category. H250 is the sentence for the “pyrophoric” classes. Under the US Hazard Communication Standard, OSHA defines both classes with the same time limit: a pyrophoric liquid is a liquid that, even in small quantities, is liable to ignite within five minutes after coming into contact with air, and a pyrophoric solid is a solid with the same property (29 CFR 1910.1200, Appendix B, sections B.9 and B.10). Each class has one category.

The statement describes behaviour on contact with air, not a flash point or a reaction with water. That is why it is easy to confuse with the flammable-liquid codes (such as flammable-liquid statements) and with water-reactive hazards, which carry different statements. The practical difference is that a pyrophoric material needs no ignition source: air alone is the trigger.

How the classification is decided

Appendix B sets a single Category 1 criterion for each class and names the UN test that produces it.

Class (OSHA App. B) Category 1 criterion Test named
Pyrophoric liquid (B.9) The liquid ignites within 5 minutes when added to an inert carrier and exposed to air Test N.3, UN Manual of Tests and Criteria, Part III, sub-section 33.3.1.5
Pyrophoric solid (B.10) The solid ignites within 5 minutes of coming into contact with air Test N.2, UN Manual of Tests and Criteria, Part III, sub-section 33.3.1.4
Pyrophoric gas (B.2) A flammable gas that ignites spontaneously in air at 54 °C (130 °F) or below Not part of H250 (see below)

Two points follow from the criteria. First, the five-minute window is part of the definition, so a substance that ignites only after longer exposure, or only when heated, does not meet the H250 criterion on that basis. Second, the classification is a property of the substance or mixture as tested, so the authoritative answer for any product you hold is the classification printed in section 2 of its own safety data sheet, not a general list.

How H250 appears on a label

PubChem’s GHS classification summary (Revision 11, 2025) lists H250 with Category 1 for both pyrophoric liquids and pyrophoric solids, the Flame pictogram GHS02 and the signal word “Danger.” The European CLP Regulation, Annex I, Table 2.9.2 gives the same elements for pyrophoric liquids: signal word “Danger” and hazard statement “H250: Catches fire spontaneously if exposed to air.”

For the Flame pictogram on its own, including what else it can signal, see the guide to GHS labels, pictograms, signal words and hazard statements. H250 is one of several hazard statements that can sit beneath that symbol.

H250 and its precautionary statements

A hazard statement is paired with precautionary statements, the P-codes. The data table below compares the P-codes listed for H250 in two sources and gives the wording of each statement from CLP Annex IV. The two sources do not list identical sets:

  • PubChem’s Revision 11 table lists prevention P210, P222 and P280; response P302+P334 and P370+P378; and storage P422.
  • CLP Table 2.9.2 for pyrophoric liquids lists prevention P210, P222, P231+P232, P233 and P280, and response P302+P334 and P370+P378. The reproduction of that table that was read shows no storage codes.

The practical reading is that P231+P232 (“Handle and store contents under inert gas”) and P233 (“Keep container tightly closed”) appear in the CLP table but not in PubChem’s aggregated list, while P422 appears in PubChem’s list but not in the CLP table text that was read. Which set appears on a given label depends on the regulation the supplier labels under and the supplier’s own selection, so a label or safety data sheet is the document to follow.

CLP Annex IV also records when some of these statements apply. P222 (“Do not allow contact with air”) applies to pyrophoric gases and to Category 1 pyrophoric liquids and solids “if emphasis of the hazard statement is deemed necessary.” P231+P232 applies to Category 1 pyrophoric liquids and solids, with the inert gas wording used if the substance or mixture reacts readily with moisture in air. P302+P334 is limited to Category 1 pyrophoric liquids. For P280 and P370+P378 the manufacturer or supplier specifies the protective equipment and the extinguishing medium, so those two statements are incomplete until the supplier fills them in.

Annex IV adds conditions to two more of the statements in the data table. P233 (“Keep container tightly closed”) is listed for pyrophoric liquids and solids among the classes where the substance is volatile and may create a hazardous atmosphere. P210 (“Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.”) applies to a long list of flammable and reactive classes and, in PubChem’s table, is among the prevention codes for H250. It may look odd next to a hazard that needs no ignition source, which is one reason to read the P-codes as a set with the hazard statement and not individually: P210 and P222 address different routes to a fire.

The Annex IV text also shows how a P-code can carry blanks the supplier must complete: P231+P232 contains the placeholder “inert gas/…”, and the supplier must specify an alternative liquid or gas if inert gas is not appropriate. A label that prints the blank unfilled is incomplete, which is another reason to treat the data table as a guide to what the codes mean and the supplier document as the final word.

H250 is not the pyrophoric gas statement

A frequent mix-up is assuming that every “pyrophoric” substance carries H250. PubChem’s table does not assign H250 to pyrophoric gases. It lists them as flammable gases, Category 1A (pyrophoric gas), with hazard statement H232, “May ignite spontaneously if exposed to air,” the Flame pictogram, the signal word “Danger” and precautionary statement P222. OSHA treats the gas separately as well: the pyrophoric gas definition in B.2 sits inside the flammable gas class, with its 54 °C threshold, rather than in the liquid and solid classes with their five-minute test.

The wording differs in a way that is easy to miss when scanning a label: H250 says the material “catches fire spontaneously,” H232 says it “may ignite spontaneously.” Use the code, not a remembered phrase, when matching an inventory record or a label.

Where it matters for labs

For a lab, an H250 on a safety data sheet is the cue to look up the handling and storage controls that the sheet and your chemical hygiene plan specify, because the hazard is triggered by ordinary air rather than by an ignition source. The relevant statements show the intent: keep the material away from air contact (P222), handle and store it under inert gas where the supplier specifies (P231+P232), keep the container closed (P233) and wear protective clothing and eye protection (P280).

Practical guidance on working with these materials is covered separately in handling water-reactive and pyrophoric chemicals, on grouping them in storage in chemical storage compatibility and segregation rules, and on where hazard classes fit in a lab’s overall programme in the common lab chemical hazard classes primer. The labelling and data-sheet duties that make the H250 statement appear at all come from the Hazard Communication Standard, summarised in hazard communication in laboratories.

A checklist for matching an H250 entry to your own records

This is an editorial checklist for reconciling an inventory entry with the sources above; it is not a handling procedure.

  1. Confirm the exact code. “H250” is the pyrophoric liquid and solid statement; “H232” is the pyrophoric gas statement. The two are not interchangeable.
  2. Confirm the class and category on the safety data sheet. For H250 the only category is Category 1, whether the product is a pyrophoric liquid or a pyrophoric solid.
  3. Confirm the pictogram and signal word. The sources read here give the Flame pictogram (GHS02) and the signal word “Danger” for H250.
  4. Record which regulation the supplier labelled under. OSHA Appendix B governs US workplace classification; CLP governs labels in the EU, where pyrophoric liquids and pyrophoric solids are separate sections of Annex I (2.9 and 2.10).
  5. Take the P-codes from the supplier’s label, not from a general list, since the sources compared in the data table differ.

Common misunderstandings

“H250 means flammable.”

Pyrophoric materials are defined by spontaneous ignition in air within five minutes, which is a different test from the flammable-liquid flash-point criteria. In OSHA’s aerosol and chemical-under-pressure tables (B.3.1 and B.3.2), the flammable components exclude pyrophoric, self-heating and water-reactive chemicals, which shows that Appendix B treats pyrophoric substances as their own group.

“The P-codes are the same on every label.”

As the table shows, even two reference sources list different P-codes for H250. Treat any general list, including this one, as a reference for understanding, and the supplier’s label and safety data sheet as the controlling document.

“A small quantity is safe.”

The OSHA definitions say “even in small quantities,” so the classification is not conditional on amount.

“H250 on a search result is the same as the flowmeter.”

Search results for the bare code mix chemical labelling with equipment model numbers. The hazard statement is a label phrase; equipment named H250 has no connection to it.

Sources

Data: Precautionary statements for H250: wording and presence in two classification sources

Compares which P-codes PubChem's GHS Rev.11 summary and the CLP Annex I Table 2.9.2 (pyrophoric liquids) list for H250, with the statement wording from CLP Annex IV Part 1. Compiled from the sources named below.

Period covered: 2025/2026.

Precautionary statements for H250: wording and presence in two classification sources
P-codeStatement wording (CLP Annex IV)Listed for H250 in PubChem GHS Rev.11Listed for H250 in CLP Table 2.9.2 (pyrophoric liquids)
P210Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.YesYes
P222Do not allow contact with air.YesYes
P231+P232Handle and store contents under inert gas/… Protect from moisture.NoYes
P233Keep container tightly closed.NoYes
P280Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/…YesYes
P302+P334IF ON SKIN: Immerse in cool water or wrap in wet bandages.YesYes
P370+P378In case of fire: Use … to extinguish.YesYes

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about H250 Hazard Statement: Catches Fire Spontaneously in Air

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →