General coding and coverage information for supply and clinic staff, not medical advice. Check the current rules with your DME MAC before billing.
Short answer
HCPCS E0562 is the code for a heated humidifier used with a positive airway pressure (PAP) device. Its descriptor is “Humidifier, heated, used with positive airway pressure device.” When a PAP or bi-level machine has a humidifier built in, the DME MAC contractor Noridian says the integrated humidification is coded E0562, separately from the base device.
What HCPCS E0562 covers
E0562 identifies heated humidification for a PAP device. Searches such as “e0562 humidifier”, “hcpcs code e0562” and “e0562 hcpcs” all point to this one code. It is an add-on to a base device, not a stand-alone therapy device: the base machine is coded separately, for example E0601 for a CPAP device (see HCPCS E0601 and related codes and what a CPAP machine is). For how the wider E, K, L and A families are organised, see DME HCPCS codes.
E0562 vs E0561
The Medicare coverage policy for PAP devices (LCD L33718) names two humidifier codes together: a non-heated humidifier (E0561) and a heated humidifier (E0562). It states that either a non-heated or a heated humidifier is covered when ordered by the treating practitioner, for use with a covered PAP device (E0470 or E0601).
| Code | Humidifier type | What the LCD says |
|---|---|---|
| E0561 | Non-heated | Covered when ordered by the treating practitioner, with a covered E0470 or E0601 device |
| E0562 | Heated | Covered when ordered by the treating practitioner, with a covered E0470 or E0601 device |
The practical difference for coding is therefore the humidifier type on the order and in the product, not a different coverage test.
Integrated (built-in) humidifiers
Noridian’s article “Correct Coding – Integrated Respiratory Products” addresses products where several functions, each with its own HCPCS code, sit in one unit. For a PAP device with integrated humidification it says to use E0601 for the base CPAP device and E0562 for the integrated humidification. For respiratory assist devices it says to use E0470 or E0471 for the base device and E0562 for the integrated humidification.
In other words, a built-in heated humidifier does not remove the humidifier line from the claim: the humidifier is still identified by E0562 alongside the base device code.
Coverage condition in LCD L33718
LCD L33718, “Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea,” applies to services performed on or after 01/01/2024 in its current revision. Two points matter for E0562:
- The humidifier must be ordered by the treating practitioner.
- It is covered for use with a covered PAP device, E0470 or E0601.
E0561 and E0562 do not appear in the accessories table of the policy, so the LCD does not give humidifiers their own replacement-frequency schedule. Check the current LCD and policy article for any limit that applies.
Verification checklist for suppliers and clinics
- Order on file. The treating practitioner’s order names the humidifier (heated or non-heated).
- Base device code. The base machine is a covered E0601, E0470 or E0471 device, coded on its own line.
- Humidifier code. A heated humidifier, standalone or integrated, is E0562; a non-heated one is E0561.
- Integrated products. Integrated humidification is not folded into the base code; it carries E0562 per the Noridian article.
- Current policy version. Confirm the current LCD and policy article with the DME MAC for your jurisdiction, since coverage documents are revised.
For the wider equipment and supplies list a sleep service keeps, see the sleep clinic supply checklist and CPAP hose types and connectors.
Common misunderstandings
- “E0562 is a CPAP machine code.” It is not; it describes the humidifier. The base device has its own code.
- “A built-in humidifier needs no separate code.” Noridian’s coding article says integrated humidification is coded E0562.
- “A humidifier is covered on its own.” The LCD ties humidifier coverage to a covered PAP device, E0470 or E0601.
FAQ
What is HCPCS E0562?
It is the code for a heated humidifier used with a positive airway pressure device.
Is an E0562 humidifier the same as a CPAP machine?
No. The CPAP device is coded separately, for example as E0601; E0562 is the humidifier.
How is an integrated humidifier coded?
Per Noridian, the base device keeps its own code (E0601, E0470 or E0471) and the integrated humidification is coded E0562.
Does Medicare cover E0562?
LCD L33718 states that either a heated (E0562) or a non-heated (E0561) humidifier is covered when ordered by the treating practitioner for use with a covered E0470 or E0601 device. Check the current version with your DME MAC.
Sources
- Noridian Healthcare Solutions, JD DME, “Correct Coding – Integrated Respiratory Products” (page last updated Nov 10, 2023; checked 2026-11-01): med.noridianmedicare.com
- CMS Medicare Coverage Database, LCD L33718, “Positive Airway Pressure (PAP) Devices for the Treatment of Obstructive Sleep Apnea” (checked 2026-11-01): cms.gov