Hospital Bed Controls: Types, Lockout and Safe Use

Hospital bed controls: control types, how lockout works, and FDA and manufacturer safety points for pendants and cords.

Written and maintained by CASRAI Editorial Board

Published

This page describes products and general use; it is not medical advice.

On this page

Hospital bed controls are the buttons, panels and handheld pendants that raise, lower and reshape a powered bed. They are used by patients, nurses and other caregivers, and by the technicians who service the bed. After reading this page you should be able to name the main control types, explain what a lockout does, and recognise the safety points that regulators and manufacturers publish about pendants and cords.

What hospital bed controls are

Hospital bed controls are the operator interface of a powered hospital bed: the means by which a person tells the built-in electric motors to change the bed’s height or the angle of its sections. US federal regulation defines the device class around them. Under 21 CFR 880.5100, an AC-powered adjustable hospital bed is a bed “with a built-in electric motor and remote controls that can be operated by the patient to adjust the height and surface contour of the bed,” and the device includes movable and latchable side rails. It is a Class II device and is exempt from premarket notification (510(k)), subject to the limitations in 21 CFR 880.9.

For the bed as a whole, see what a hospital bed is; for the parts that the controls drive, see the hospital bed parts guide.

How the controls work and where they sit

The controls sit between the user and the motors. Pressing a function sends a command to the motor for that function, such as head section, knee section or overall height. Where they are mounted varies by model, so the manufacturer’s instructions for use (IFU) govern. One published example is the Hillrom Centrella Smart+ product reference guide (rev. 4, 2018), which describes caregiver control panels on both sides of the head siderails, patient controls on the patient side of the head siderails, and an optional handheld patient pendant. Other manufacturers lay out their beds differently.

Types of hospital bed controls

Control type Typical user Example of what it offers (one manufacturer)
Caregiver control panel Nurses and other caregivers Centrella Smart+: panels on both sides of the head siderails, including the lockout control
Patient siderail controls Patient Centrella Smart+: nurse call, head up/down, knee up/down and a head-of-bed angle indicator on the patient side of the head siderails
Handheld patient pendant (optional on the example bed) Patient Centrella Smart+: head, knee and foot up/down, stand assist and a stay-in-bed indicator; some versions also control television or lighting
Remote controls operable by the patient (regulatory description) Patient 21 CFR 880.5100 describes remote controls that adjust the height and surface contour

Source for the Centrella rows: Hillrom Centrella Smart+ product reference guide, rev. 4. The regulatory row: 21 CFR 880.5100. Functions and layouts differ between manufacturers and models.

What a lockout does

A lockout lets a caregiver disable selected bed functions so they cannot be activated by accident or by the patient. In the Centrella Smart+ guide, the lockout control “disables bed functions for both the patient and caregiver,” and locking out certain functions may cause other dependent functions to be locked out as well. An indicator light shows that a function is locked out. The same guide states that when its CPR function is activated, any controls that are locked out become unlocked. Whether a given bed behaves this way depends on the model, so the bed’s own IFU should be read before relying on lockout. A lockout is a bed feature, not a substitute for a clinician’s assessment of a patient.

Controls and the call system are separate: the nurse call button on a bed signals staff through the facility’s system, described in what a nurse call light is.

Safe use and handling basics

  • Pendants and cords can overheat. In a 2026 FDA notice about one home-care bed model, the agency stated that the hand pendant and pendant cords may overheat and, in some instances, pose a risk of fire. Overheating can follow exceeding the bed’s weight limit, an obstruction to bed movement, or jammed components or motor.
  • Store the pendant off the mattress. That notice advises hanging the pendant on the headboard or footboard when not in use and never storing it on the mattress. Hillrom’s guide also describes pendant storage holders on the siderails.
  • Stop using a damaged or hot pendant. The FDA notice advises unplugging the bed and calling for service if the pendant is hot, wiring is damaged, or there is smoke or sparking.
  • Watch cord length. Hillrom’s guide carries a strangulation warning about secure cable length near the bed’s USB port.
  • Entrapment is a separate hazard. FDA reports receiving 901 incidents of patients caught, trapped, entangled or strangled in hospital beds, mostly frail or confused older adults. FDA’s guidance for bed rails advises assessing an individual patient’s needs and consulting the manufacturer and the facility’s risk managers. FDA’s 2006 dimensional guidance concerns entrapment zones and does not address controls.

Problems with a device can be reported through the FDA’s medical device reporting channels; see medical device reporting (MDR) and the FDA entry.

Common mistakes

  • Assuming one bed’s button layout applies to another model; the IFU for the specific bed governs.
  • Leaving the pendant on the mattress, where FDA warns it should not be stored in the case of the notified bed.
  • Assuming a locked-out function is unavailable in every circumstance; on the example bed, activating CPR unlocks locked-out controls.
  • Continuing to use a bed with a hot pendant, damaged wiring, smoke or sparking.

Facilities that source beds and related furniture can browse hospital furniture and facility supplies.

Frequently asked questions

Who can use hospital bed controls?

Both patients and caregivers. The federal definition in 21 CFR 880.5100 refers to remote controls the patient can operate, and manufacturers such as Hillrom describe separate caregiver panels with a lockout to limit what the patient can change.

What is a hospital bed lockout?

A caregiver-set feature that disables selected bed functions. On the Centrella Smart+ it affects both patient and caregiver controls, and locked-out controls unlock when CPR is activated.

Can a bed pendant overheat?

FDA has stated that on one home-care bed model the pendant and cords may overheat and pose a fire risk, particularly after overload or obstruction. Follow the IFU and stop using any hot or damaged pendant.

Are hospital beds regulated?

Yes. AC-powered adjustable hospital beds are Class II devices under 21 CFR 880.5100.

Sources

  • 21 CFR 880.5100, AC-powered adjustable hospital bed: law.cornell.edu/cfr/text/21/880.5100 (read 2026-11-12).
  • FDA, Hospital Beds (page dated 08/23/2018): fda.gov (read 2026-11-12).
  • FDA, Electronic homecare bed correction: Medline updates use instructions for homecare beds: fda.gov (read 2026-11-12).
  • Hillrom, Centrella Smart+ product reference guide, rev. 4: hillrom.com (read 2026-11-12).
  • FDA, Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment, March 10, 2006: fda.gov (read 2026-11-12).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Hospital Bed Controls: Types, Lockout and Safe Use

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →