Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop curtain track supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Hospital Curtain Track: Types, Parts and Standards

Parts, types and hooks of hospital cubicle curtain track, with SHTM 66 figures for strength, height and wear, and the sprinkler mesh point.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Short answer: A hospital curtain track (also called a cubicle curtain track) is the rail system fixed to a wall or ceiling that carries privacy curtains around a bed space on gliders and hooks or buttons. Scottish NHS guidance (SHTM 66, 2006) sets out its parts, test figures and mounting heights; US manufacturers sell several track types.

This page gives general product information for lab, clinic and facilities staff. It is not medical advice and not an installation procedure.

Definition and scope

SHTM 66, Cubicle curtain track (Health Facilities Scotland, NHS National Services Scotland, version 1.0, December 2006), defines a cubicle curtain track system as “a component assembly to support curtains forming cubicles”. It separates a suspended track, fixed at a level significantly below the ceiling soffit, from a ceiling fixed track, fixed directly to the soffit. Track height is measured from finished floor to the underside of the track. This is Scottish guidance of 2006, not a US requirement, and it asks readers to use the latest edition.

Parts of a track system

SHTM 66 (paragraph 2.1) lists the constituent parts:

  • the track itself;
  • wall fixing devices;
  • direct-to-ceiling fixings, vertical hangers or V-hangers;
  • bay connectors and stop ends;
  • a curtain loading device;
  • gliders or runners;
  • hooks or buttons;
  • low weight release systems (anti-ligature).

How curtain track is used in practice

Hooks, buttons and hookless carriers (hospital curtain hooks)

SHTM 66 (2.10) says gliders or runners are designed to attach curtains “by hooks or buttons”, and (3.34) that hooks or buttons are fitted to the curtain before delivery at accurate spacing so the curtain draws around bends. Construction Specialties, a manufacturer, lists a hookless system, On the Right Track, and states that curtains “can be removed in less than a minute”; that is a manufacturer claim. See our guide on privacy curtains for fabric and change intervals.

Loading devices and curtain changes

Each SHTM 66 system includes a device for loading and unloading curtains (2.11). The guidance says such devices bring hooking and unhooking to normal working height, reducing operator fatigue and the “risk of accidents when working at or near ceiling height”, and reducing the risk of cross-infection from moving soiled curtains. It notes one device per floor is usually adequate (3.30 to 3.33).

Parking the curtain

SHTM 66 (3.24 to 3.28) notes that curtains parked along a wall give maximum observation but are less easy to draw, while curtains parked at right angles give less observation, more privacy and are easier to draw. Track length for parking is about 15% of track length for cotton fabric; its worked example is a 2900 x 2500 mm bed space needing 810 mm of track for parking. Curtain fullness “can vary from 5 to 25%” depending on hospital policy (3.23).

Types of curtain track (cubicle curtain track)

Type What the source says Source
Suspended track Fixed significantly below the ceiling soffit; height normally 2100 mm to the underside. SHTM 66, 1.10 and 3.4
Ceiling fixed track Fixed directly to the soffit; normally limited to ceiling heights up to 2700 mm, with the 600 mm gap closed by a lightweight fabric net that passes light and air. SHTM 66, 1.10 and 3.5
Collapsible (anti-ligature) track For in-patient mental health settings; releases under an abnormal load, with anti-deflection devices so only full collapses occur. SHTM 66, 1.10 and 3.17 to 3.18
Standard aluminum track A manufacturer lists Standard 6062 in anodized aluminum or white powder coated, plus Narrowline, hookless and Qwik Switch tracks. Construction Specialties

Where it matters for labs, clinics and supply decisions

Strength and wear figures

SHTM 66 sets track suspension breaking strength “not less than 180 kg” between upper and lower fixing points at any location within the collapsible subsystem, and says the weakest components should be the gliders or runners (2.5). Gliders, runners and wearing surfaces should withstand “at least 20,000 cycles” of curtain movement (2.12). Fixing spacing follows the manufacturer’s recommendations (3.7). A manufacturer states its 1062N carriers have the lowest weight capacity, up to 50 pounds per carrier; carrier ratings differ between products.

Fire sprinklers

An HFM Magazine article (Brian O’Connor, PE, 24 March 2025) on NFPA 13 sprinkler obstructions states that privacy curtains in light-hazard patient care areas can avoid being treated as obstructions when supported by a fabric mesh attached to a ceiling track, with openings covering at least 70% of the curtain’s area and the mesh extending at least 22 inches from the ceiling. The article refers mainly to the 2010 NFPA 13 edition. Confirm the adopted edition with the authority having jurisdiction; see NFPA 101 Life Safety Code.

Infection control and cleaning

SHTM 66 (2.13) says no component should support the growth of bacteria or fungi or harbour insects or mites, and (3.38) that construction should withstand cleaning regimes. It notes fabric netting may be difficult to clean (3.20). For room-level cleaning, see our guide to terminal cleaning.

Ligature risk

SHTM 66 (3.17 to 3.18) recognises curtain and shower rails as a ligature point in mental health in-patient settings and describes collapsible-type rails as the alternative to non-collapsible ones, with regular maintenance checks and load tests per manufacturers’ instructions.

For wider room planning, see the exam room furnishing checklist.

Common misunderstandings

  • “Curtain track is one standard product.” The sources describe several track types, mounting methods and carrier ratings.
  • “A 2006 Scottish document applies everywhere.” SHTM 66 is Scottish guidance; it does not bind US facilities.
  • “Any hook fits any track.” SHTM 66 (2.10) says gliders or runners are designed for attaching curtains by hooks or buttons; carrier and track products differ, so check the manufacturer’s product information.
  • “Curtains and track are the same item.” The curtain hangs from the track, but the track is a fixed assembly; SHTM 66 (3.36) says to follow the manufacturer’s recommendations for periodic inspection and maintenance.

FAQ

What is a hospital curtain track?

It is the wall or ceiling-fixed rail assembly that supports privacy curtains around a bed or treatment space, using gliders and hooks or buttons.

What is the difference between suspended and ceiling fixed track?

Suspended track sits significantly below the ceiling soffit; ceiling fixed track is fixed directly to it. SHTM 66 gives a typical suspended height of 2100 mm.

Do hospital curtains need hooks?

Not always. SHTM 66 describes hooks or buttons, and manufacturers also sell hookless systems.

Why would a curtain track need to collapse?

In mental health in-patient settings, rails are a recognised ligature point, so SHTM 66 describes collapsible track that releases under an abnormal load.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Hospital Curtain Track: Types, Parts and Standards

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →