General product and use information for laboratory, clinic and sterile-processing staff. This page is not medical advice and does not give procedure steps; follow the sterilizer manufacturer’s instructions for use and your facility’s policies.
Short answer
Hydrogen peroxide sterilization means using hydrogen peroxide vapor or gas plasma, at low temperature, to sterilize heat- and moisture-sensitive medical devices. The FDA now treats vaporized hydrogen peroxide (VH2O2) as an Established Category A sterilization process, and the CDC says linen and paper wraps should not be used with hydrogen peroxide gas plasma. Which model of sterilizer you own decides which devices and packaging are allowed.
Definition and scope
The phrase covers more than one thing, and search results mix them. This page separates three meanings so you can reach the right guide:
| What people mean | Where it applies | Read next |
|---|---|---|
| Vaporized hydrogen peroxide (VH2O2) device sterilization | Low-temperature sterilization of reusable medical devices in a chamber | This page, then low-temperature sterilization method selection |
| Hydrogen peroxide gas plasma (HPGP) | A chamber process the CDC groups with other low-temperature methods | STERRAD and hydrogen peroxide gas plasma sterilization |
| VHP decontamination of rooms and enclosures | Decontaminating spaces rather than sterilizing packaged devices | VHP decontamination |
This is a different topic from using liquid hydrogen peroxide as a surface disinfectant, which is compared with isopropyl alcohol in hydrogen peroxide vs isopropyl alcohol. For the wider picture of sterilization methods and standards, see sterilization technology.
How it is used in practice
According to STERIS, a sterilizer manufacturer, liquid hydrogen peroxide is turned into vapor that fills the chamber, contacts all surfaces and penetrates lumens, and the vapor is then removed and converted to water and oxygen. This is the manufacturer’s description of its own process type; individual cycles differ by sterilizer model.
Two points from regulators and public-health guidance frame everyday use:
- Regulatory status. The FDA moved VH2O2 from Established Category B to Established Category A after it recognized ISO 22441:2022, the standard for low-temperature vaporized hydrogen peroxide sterilization. The FDA also revised its 510(k) sterility guidance in January 2024, which changes what manufacturers include in 510(k) submissions that use VH2O2 (FDA, page current as of 14 May 2025, checked 1 November 2026).
- Staff exposure. OSHA’s Annotated Table Z-1 lists a permissible exposure limit of 1 ppm for hydrogen peroxide (OSHA Annotated Table Z-1, checked 1 November 2026).
Types and related concepts
Vaporized hydrogen peroxide sterilization
Vaporized hydrogen peroxide sterilization is the FDA-recognized category above, built around ISO 22441:2022. STERIS notes that heat- and moisture-sensitive devices are not always validated or compatible with all models of VHP sterilizers, and that cycle limits are set by each sterilizer’s design and the manufacturer’s validation.
Hydrogen peroxide gas plasma
The CDC lists hydrogen peroxide gas plasma among the low-temperature methods it addresses in its sterilizing-practices page. See the dedicated STERRAD guide for how that process is described.
Where it matters for labs, clinics and supply decisions
Three things need to line up: the device, the packaging and the monitoring routine. The table below turns the sourced points above into a checklist of what to confirm with the sterilizer maker and in your own records.
| Item to confirm | What the source says | Source |
|---|---|---|
| Device compatibility | Heat- and moisture-sensitive devices are not always validated or compatible with all models of VHP sterilizers, so ask for the compatibility list for your specific model. | STERIS knowledge center (manufacturer), checked 1 Nov 2026 |
| Packaging | Linens and paper should not be used to wrap medical items for hydrogen peroxide gas plasma. | CDC, Sterilizing Practices (page dated 28 Nov 2023), checked 1 Nov 2026 |
| Routine biological monitoring | Low-temperature sterilizers, including hydrogen peroxide gas plasma, should be monitored at least weekly with the appropriate commercial spore preparation. G. stearothermophilus spores are used for hydrogen peroxide gas plasma sterilizers. | CDC, Sterilizing Practices |
| Response to a positive spore test | Under the CDC’s more conservative approach for methods other than steam, any positive spore test is assumed to represent sterilizer malfunction. | CDC, Sterilizing Practices |
| Regulatory status of the process | VH2O2 is an Established Category A sterilization process; ISO 22441:2022 is recognized. | FDA, Sterilization for Medical Devices (current as of 14 May 2025) |
For packaging products, see sterilization wrap and Tyvek pouches for sterilization, which cover which methods each material suits.
Common misunderstandings
- “Hydrogen peroxide sterilization is the same as using hydrogen peroxide as a disinfectant.” Not the same. Chamber sterilization is a validated process on devices; surface disinfection is a different use.
- “All wraps work in any sterilizer.” The CDC states linens and paper should not be used to wrap medical items for hydrogen peroxide gas plasma.
- “Vapor and plasma are interchangeable labels.” The FDA’s Category A status is stated for vaporized hydrogen peroxide; the CDC page discusses gas plasma separately. Check which process your sterilizer uses.
- “A listed device works in every model.” STERIS states compatibility is not always validated across all models.
FAQ
Is vaporized hydrogen peroxide sterilization FDA recognized?
Yes. The FDA considers vaporized hydrogen peroxide an Established Category A sterilization process, following its recognition of ISO 22441:2022.
Can paper or linen wraps be used?
The CDC says linens and paper should not be used to wrap medical items for hydrogen peroxide gas plasma sterilization.
How often is a hydrogen peroxide sterilizer monitored with spores?
The CDC says low-temperature sterilizers, including hydrogen peroxide gas plasma, should be monitored at least weekly with the appropriate commercial spore preparation.
Sources
- FDA, Sterilization for Medical Devices (checked 1 November 2026).
- CDC, Sterilizing Practices, based on the 2008 Guideline for Disinfection and Sterilization in Healthcare Facilities (checked 1 November 2026).
- STERIS, Hydrogen peroxide sterilization knowledge center (manufacturer page, checked 1 November 2026).
- OSHA, Annotated Table Z-1, hydrogen peroxide entry (checked 1 November 2026).