Hyfrecator: What It Is and What to Check Before Specifying One

What a Hyfrecator is, how its terminals and modes are defined, and which specs and safety warnings to confirm before a clinic or lab specifies one.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product information, not medical advice. This page describes a device class and what its maker’s manual says; it does not describe clinical technique.

Short answer

A Hyfrecator is a brand of electrosurgical generator made by CONMED, described by its maker as an office-based unit that uses high-frequency electrical current to dry (desiccate), coagulate or fulgurate tissue. “Hyfrecator” is the brand name; the generic class is an electrosurgical (electrodesiccation) unit. Before a clinic or lab specifies one, check the voltage version, grounded-outlet requirement, accessory compatibility and the manual’s safety warnings.

Setting up a dermatology room? See the dermatology office supply checklist for the wider list of supplies. This page covers the one device.

Definition and scope

The U.S. National Library of Medicine’s AccessGUDID record for the HYFRECATOR 2000 (model 7-900-100, CONMED Corporation) classifies it under the GMDN term “Electrosurgical system generator”, a device that generates radio-frequency electrical current for cutting and coagulating soft tissue. The record lists FDA product code GEI, “Electrosurgical, Cutting, Coagulation and Accessories” (AccessGUDID, checked 2026-11-03).

Under 21 CFR 878.4400, an electrosurgical cutting and coagulation device is “a device intended to remove tissue and control bleeding by use of high-frequency electrical current”, and it is classified as Class II (eCFR, checked 2026-11-03). For the broader device family, see what an electrosurgical unit is.

Hyfrecator 2000

The Hyfrecator 2000 is the model described in the manufacturer’s owner’s manual. GUDID lists a separate record for the 100 VAC, 50/60 Hz version, so line voltage is a specification to confirm, not an assumption.

How it is used in practice

Hyfrecator uses

The CONMED manual says the unit has “a wide range of applications – from dermatology and gynecology to ophthalmology and urology”, and describes it as designed for office-based electrosurgery. This page does not cover procedures or settings.

Terminals and configurations

According to the manual, the Hyfrecator 2000 has three outputs: a high-output terminal (zero to 35 watts), a low-output terminal (zero to 20 watts), and a bipolar terminal (zero to 35 watts; a footswitch is required when forceps are used). It can run as a monoterminal unit without a dispersive plate, which the manual says covers “the vast majority” of its procedures, as a monoterminal unit with a dispersive plate, or as a bipolar unit.

Terms and modes compared

The manual defines the vocabulary used for this device. Each row below comes from its terminology section.

Term Origin given in the manual What the manual says
Desiccation Latin “desiccare”, to dry The current evaporates cellular fluids.
Fulguration Latin “fulgur”, an act of lightning The electrode is held slightly away from tissue, producing sparking; it “limits tissue destruction to a shallow area”.
Coagulation Latin “coagulare”, to clot Can be monoterminal (with a dispersive plate) or bipolar.
Bipolar – Current stays at the surface between the forceps tines.

Where it matters for labs, clinics and supply decisions

These are documents and specifications the sources identify as worth confirming. They are not a ranking of products.

  • Owner’s manual in hand. The manual contains the warnings, terminal ranges and accessory list; keep the current edition with the unit.
  • Voltage version. GUDID carries separate records for different line-voltage versions of the Hyfrecator 2000.
  • Grounded outlet. The manual says to connect to a properly grounded receptacle and not to use extension cords or two-wire adapters.
  • Accessories. The manual lists electrodes (including a fine-wire epilation electrode), bipolar forceps, a footswitch and an optional dispersive plate cord, and states that existing Hyfrecator accessories are compatible.
  • Device class and product code. Class II under 21 CFR 878.4400 for electrosurgical cutting and coagulation devices; GUDID product code GEI for this model. The wider consensus standard for this equipment family is covered in IEC 60601-2-2.
  • Return-path accessory. For monoterminal use with a plate, see electrosurgical grounding pads.

Common misunderstandings

“Hyfrecator” and “electrosurgical unit” are not the same thing

Hyfrecator is a CONMED brand. Other manufacturers make electrodesiccation and electrosurgical generators, and GUDID’s generic term for this one is “Electrosurgical system generator”.

“Safe” does not mean “no precautions”

The manual calls it one of the safest office-based electrosurgery units, yet it also carries warnings, including one about cardiac pacemakers, so the manual should be read before a unit is specified.

It is not rated for flammable environments

The manual states electrosurgery should never be performed in the presence of flammable anesthetics, flammable prep solutions or drapes, or oxidizing gases such as nitrous oxide, and that the Hyfrecator 2000 “is not flammable anaesthetic-proof equipment”. It also warns that the tips of recently activated accessories can be hot enough to burn or ignite flammable materials.

FAQ

What is a Hyfrecator used for?

The manufacturer lists applications across dermatology, gynecology, ophthalmology and urology, in office-based settings.

What is a Hyfrecator 2000?

A CONMED electrosurgical generator with high, low and bipolar outputs, listed in AccessGUDID under model 7-900-100 (100 VAC, 50/60 Hz version).

Is a Hyfrecator regulated as a medical device?

Electrosurgical cutting and coagulation devices are Class II devices under 21 CFR 878.4400. The GUDID record for the Hyfrecator 2000 uses FDA product code GEI. See also what counts as a medical device.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Hyfrecator: What It Is and What to Check Before Specifying One

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →