Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop hyperbaric oxygen chamber supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Hyperbaric Oxygen Chamber: Definition and Fire Safety

What a hyperbaric oxygen chamber is under the UHMS definition (2.0 ATA, medical-grade oxygen) and what the FDA’s 25 August 2025 fire-safety letter asks of facilities.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

A hyperbaric oxygen chamber is a pressure vessel in which a patient breathes medical-grade oxygen at pressure above normal atmospheric pressure. The Undersea and Hyperbaric Medical Society (UHMS) defines hyperbaric oxygen (HBO) therapy as treatment at a pressure of not less than 2.0 ATA (202.65 kPa) while breathing physician-prescribed medical-grade oxygen, and the FDA warned providers in August 2025 about fires involving these devices.

This guide is general product and safety information for laboratory, clinic and supply staff. It is not medical advice, and it does not describe treatment procedures or dosing.

Definition and scope

The UHMS HBO Indications page (checked 31 October 2026) is specific about what qualifies as hyperbaric oxygen therapy. Pressure alone is not enough, and neither is oxygen alone: the definition ties together pressure, gas purity and a physician’s prescription.

Element What the UHMS page states
Minimum pressure Not less than 2.0 ATA (202.65 kPa)
Gas Physician-prescribed medical-grade oxygen; more than 99.0% purity is described as the only acceptable gas
Typical range Scientifically supported hyperbaric treatments are usually delivered at 1.9 to 3.0 ATA

Source: UHMS, HBO Indications, checked 31 October 2026. For supply and equipment decisions the practical reading is that a device or setting that delivers lower pressure, or a gas other than medical-grade oxygen, does not meet this definition of HBO therapy.

How a hyperbaric oxygen chamber is used

The FDA describes hyperbaric oxygen therapy (HBOT) as breathing 100% oxygen in a special chamber in which the air pressure is raised above normal (FDA letter to health care providers, 25 August 2025, checked 31 October 2026). Because the chamber combines raised pressure with a high-oxygen environment, the FDA treats correct use of the device, as written in the manufacturer’s instructions for use (IFU), as central to safety.

Where the UHMS indications list fits

The UHMS publishes a list of approved hyperbaric oxygen indications on the same HBO Indications page. This guide does not reproduce it or advise on who should receive treatment; that is a decision for a physician. Facilities planning what to stock around a chamber can pair the definition above with the hyperbaric chamber facility supply checklist; for wound-care supplies used in the same settings, see the wound vac and NPWT clinic supply checklist.

Fire safety: what the FDA letter asks of facilities

The FDA’s letter of 25 August 2025 states that it is aware of recent reports of fires involving HBOT devices that resulted in serious injuries and deaths, and that the root cause of these events is not currently known. Its recommendations for providers and facilities are summarised below.

FDA recommendation What it means for equipment and supply staff
Follow the manufacturer’s IFU for each device Keep the current IFU for every chamber model on file and in use
Take fire prevention seriously, including proper grounding Ground equipment where the manufacturer requires it
Train staff Staff operating a chamber need training on that device
Monitor and supervise patients for the full treatment Supervision covers the whole session
Follow cleaning, maintenance intervals and safety checks Use the manufacturer’s schedule, not a generic one
Keep out items the manufacturer prohibits, such as electrical or static-producing items Check items against the IFU before they enter a chamber
Use hyperbaric-compatible clothing such as cotton The FDA notes wool and synthetics generate more static

Source: FDA, Follow Instructions for Safe Use of Hyperbaric Oxygen Therapy Devices, 25 August 2025. For the wider fire and life-safety code context in health care buildings, see the NFPA 99 Health Care Facilities Code guide.

Common misunderstandings

Is any pressurized chamber a hyperbaric oxygen chamber?

No. Under the UHMS definition, HBO therapy means at least 2.0 ATA with physician-prescribed medical-grade oxygen. A lower-pressure device does not meet that definition.

Is oxygen at pressure low-risk?

No. The FDA has reported fires with serious injuries and deaths and asks facilities to follow the IFU, grounding, supervision and prohibited-item rules.

Does the UHMS list mean hyperbaric oxygen suits any condition?

No. The list covers only the specific indications named on the UHMS page, and treatment decisions belong to a physician.

FAQ

What is a hyperbaric oxygen chamber?

A chamber in which air pressure is raised above normal while the patient breathes oxygen. UHMS defines HBO therapy as at least 2.0 ATA with physician-prescribed medical-grade oxygen.

What oxygen purity does the UHMS specify?

The UHMS page says medical-grade oxygen, with more than 99.0% purity, is the only acceptable gas.

What pressures are typically used?

The UHMS page says scientifically supported hyperbaric treatments are usually delivered at 1.9 to 3.0 ATA.

What has the FDA said about safety?

In its 25 August 2025 letter the FDA reported fires with serious injuries and deaths, said the root cause is not known, and asked providers to follow each device’s IFU.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Hyperbaric Oxygen Chamber: Definition and Fire Safety

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →