Written and maintained by CASRAI Editorial Board
Published
On this page
IMGT/V-QUEST is a free web tool from IMGT, the international ImMunoGeneTics information system, that aligns immunoglobulin (IG, antibody) and T cell receptor (TR) variable-region nucleotide sequences against IMGT reference sequences. It names the closest V, D and J genes and alleles, reports mutations, analyses the junction and numbers the V-region with the IMGT unique numbering. The online version takes up to 50 sequences per run.
Short answer: what IMGT/V-QUEST does and what it needs
You paste or upload cDNA or genomic nucleotide sequences in FASTA or FASTQ format, choose a species and a receptor type or locus, and the tool returns, for each sequence, the closest V-gene and allele, the D and J genes when it can find them, the junction, the framework (FR-IMGT) and complementarity-determining (CDR-IMGT) regions, and a table of mutations against the closest germline allele. According to the IMGT documentation, the output is available as an HTML or text “Detailed view”, a “Synthesis view”, a spreadsheet or zip of CSV files, or AIRR-formatted results.
Three limits decide whether it fits your data. The online version accepts at most 50 nucleotide sequences per submission. It works on rearranged V-J and V-D-J genes and on germline V genes, but not on germline D or J genes or partially rearranged D-J genes. And it expects sequences that contain a V-region it can number, so very short or non-rearranged fragments may fail or give aberrant results. For high-throughput sequencing data, IMGT provides a separate portal, IMGT/HighV-QUEST, covered below.
Definition and scope
The name stands for V-QUEry and STandardization. The IMGT tool page describes IMGT/V-QUEST as a sequence alignment tool for the nucleotide sequences of the variable regions and domains of immunoglobulins and T cell receptors, developed by the LIGM laboratory (Université Montpellier 2, CNRS) and on the web since 7 July 1997. The 2008 Nucleic Acids Research paper that the tool’s own documentation asks users to cite (Brochet, Lefranc and Giudicelli) describes it as a system for the standardized analysis of rearranged IG and TR nucleotide sequences, and states that it integrates two other IMGT tools: IMGT/JunctionAnalysis for the V-J and V-D-J junctions and IMGT/Automat for a full V-J and V-D-J region annotation.
“Standardized” has a specific meaning here. Every result is expressed in IMGT rules: gene and allele names come from the IMGT reference directory, and the V-region is numbered with the IMGT unique numbering, which is what delimits the FR-IMGT and CDR-IMGT regions and produces the IMGT Collier de Perles (a two-dimensional representation of the variable domain). That is why a CDR3 length or a framework position reported by V-QUEST can be compared across receptors and across laboratories. For background on the region the junction analysis is built around, see the CASRAI guide to the CDR3 hypervariable loop.
What it does not analyse
The user guide is explicit about the boundaries. IMGT/V-QUEST works with cDNA L-V-J-C and L-V-D-J-C sequences, with rearranged V-J and V-D-J genes and with germline V genes. It does not work with germline D genes, germline J genes or partially rearranged D-J genes. It does not work with out-of-frame pseudogenes, because their translated sequences cannot be numbered with the amino acid IMGT unique numbering; the guide points users to IMGT/BlastSearch for those, comparing against the IMGT/GENE-DB reference sequences. It may not work, or may give aberrant results, for short non-rearranged sequences, sequences containing a cluster of V genes, or sequences with too long a 5′ or 3′ untranslated region; for these the guide suggests IMGT/BlastSearch against IMGT/LIGM-DB.
How an IMGT/V-QUEST run works in practice
The Search page, as the user guide describes it, has five sections: your selection, sequence submission, display of results, advanced parameters and advanced functionalities. The order of decisions below follows that page.
1. Choose the species, the receptor type or locus, and the molecule type
You select the species first, then either the antigen receptor type (IG or TR) or a locus: IGH, IGK or IGL for immunoglobulins, TRA, TRB, TRG or TRD for T cell receptors. Only loci with an available reference directory are listed for a given species. The guide gives species-specific notes: the mouse sets contain one sequence per allele with no restriction on strain (the mouse IG set includes nine sequences from Mus spretus), while the option “Mus musculus (strain C57BL/6J)” restricts the sets to alleles identified in that strain; for Oncorhynchus mykiss (trout) you can compare against all reference alleles or against the “Swanson” or “Arlee” strain alleles only; and for chicken (Gallus gallus) IGH repertoire analysis the guide tells users to select the “F + ORF” reference directory in the advanced parameters, or “F+ORF+ in-frame P” to compare against pseudogenes. Check these notes against your species before interpreting a result, because the reference set determines what “closest allele” means.
Next you state the molecule type: unknown, genomic DNA or cDNA. For unknown or genomic DNA input, only V-domains are analysed and annotated. For cDNA, the analysis covers the full L-V-(D)-J-C region, annotating the leader (L) and constant (C) regions when present. The guide also notes that the scFv analysis is not yet available for cDNA sequences, and advises re-checking that the receptor type or locus is still selected before launching the analysis.
2. Submit the sequences
The input rules in the user guide read as a checklist:
- Up to 50 nucleotide sequences per submission in the online version.
- FASTA or FASTQ format, pasted into the text area or loaded from a local file.
- FASTA or FASTQ headers longer than 50 characters are truncated, spaces and tabs in headers are replaced by underscores, and only the first 35 characters of a header are shown in the alignments.
- In the sequence lines, blanks and the characters “.”, “/”, “-“, “_” and the digits 0 to 9 are removed automatically, so copied GenBank-style blocks with line numbers can be pasted directly.
- Leading and trailing “n” characters are trimmed before analysis, and the numbers trimmed are reported.
- When insertion and deletion search is switched on, the 2008 paper states that a run is limited to 10 sequences.
The submission page also links test sequence sets, including human IG and TR examples, which are useful for checking that your locus and species selection returns what you expect before you upload real data.
3. Adjust the advanced parameters only when you have a reason
The advanced parameters change the defaults for the alignment and for IMGT/JunctionAnalysis. The user guide lists four choices of reference directory set: F+ORF (functional and open-reading-frame genes only); F+ORF+in-frame P, which is the default and adds pseudogenes with an in-frame V-region; and the same two sets including orphons. You can also compare your sequences with all alleles or only allele *01 of each gene, customise the reference set, switch on the search for insertions and deletions, and change the number of D genes and accepted mutations that the junction analysis allows. The default values for each locus, and the last V-region codon used for identifying the closest allele, are in the data table below the guide text.
The defaults matter for interpretation. For example, the guide lists one allowed D gene for IGH and TRB and three for TRD, and, for IGH, two accepted mutations in the 3′ end of the V-region and 5′ end of the J-region and four in the D-region, whereas the TRA, TRB, TRD and TRG defaults accept none in the V and J ends. Junction results are therefore conditional on those settings, and the guide notes that results are not given for every sequence, for instance when reference sequences are partial or the mutation counts exceed the limits.
4. Choose the output you need
Because the results are produced in several forms, decide before the run which one your downstream work needs. The table below maps each output to its content, using the descriptions in the IMGT user guide.
| Output | What the IMGT user guide says it contains | Formats |
|---|---|---|
| Detailed view | Results for each submitted sequence: V, D, J, L and C alignments, IMGT/JunctionAnalysis results, the nucleotide and amino acid junction, V-region alignment, translation and protein display, mutation and amino acid change table and statistics, mutation hotspots, gapped FASTA sequences, annotation by IMGT/Automat and the IMGT Collier de Perles | HTML or text (the Collier de Perles is not included in text) |
| Synthesis view | A summary table plus, for each V gene and allele, the alignment of the sequences that express it, protein displays (optionally coloured by IMGT amino acid classes or showing only mutations) and the most frequent amino acid per position in each FR-IMGT and CDR-IMGT | HTML or text (text omits the IMGT/JunctionAnalysis results) |
| Excel / CSV | Up to eleven main sheets or CSV files (Summary, IMGT-gapped and ungapped nucleotide and amino acid sequences, Junction, V-region mutation and amino acid change table, nucleotide mutation statistics, amino acid change statistics, mutation hotspots, Parameters) and a twelfth for scFv analysis | Open in a spreadsheet, download a zip of CSV files, or display one CSV file in the browser |
| AIRR format | A zip with a Parameters.txt file (program version, reference directory release, date and parameters used) and the tab-separated file vquest_airr.tsv | Zip archive |
The Parameters sheet or Parameters.txt file is worth keeping with any exported result: it records the program version, the reference directory release and the settings, which are the details a methods section needs in order to make an IMGT/V-QUEST analysis reproducible. The guide states that the eleven main CSV files in the online tool are identical to those provided by IMGT/HighV-QUEST, which makes the two tools’ spreadsheet outputs structurally comparable.
5. Read the sequence analysis category and the warnings
Each result carries a “sequence analysis category” that records how the sequence was processed. The user guide defines four categories:
| Category | Meaning |
|---|---|
| 1 | Analysis without the search for insertions and deletions in the V-region |
| 2 | Analysis with the insertion and deletion search, with corrections if any |
| 3 | Analysis on the complementary reverse sequence, without the insertion and deletion search |
| 4 | Analysis on the complementary reverse sequence, with the insertion and deletion search and corrections if any |
Categories 3 and 4 tell you that the tool analysed the reverse complement of the sequence you submitted, which matters if you are comparing the reported nucleotide sequence with your raw read. The result page also reports counts that affect confidence: the numbers of trimmed “n” at each end, the number of missing nucleotides at the 5′ end of the V-region or 3′ end of the J-region for partial sequences, and the number of uncertain (non a, t, g, c) nucleotides in the V-region. If a sequence shows “no results”, the guide says this may mean the V-region is absent or too short to analyse, or that no reference directory is available for the receptor type you selected.
IMGT/V-QUEST versus IMGT/HighV-QUEST
IMGT/V-QUEST and IMGT/HighV-QUEST are separate IMGT tools. The HighV-QUEST page describes IMGT/HighV-QUEST as the IMGT web portal for immunoglobulin or antibody and T cell receptor analysis from NGS, high-throughput and deep sequencing, and it has its own login. IMGT/V-QUEST is the single-run tool described above. The table lists only the points the IMGT pages state.
| Point | IMGT/V-QUEST | IMGT/HighV-QUEST |
|---|---|---|
| Stated purpose | Standardized analysis of IG and TR variable-region nucleotide sequences, with alignments, junction and mutation analysis | Web portal for IG and TR analysis from NGS, high-throughput and deep sequencing |
| Sequences per submission (online) | Up to 50 nucleotide sequences | Not stated on the portal’s front page |
| Spreadsheet output | Eleven main CSV files, plus a twelfth for scFv | The same eleven main CSV files (as stated in the V-QUEST user guide) |
| Citation requested | Brochet, Lefranc and Giudicelli, Nucleic Acids Research 36:W503-508 (2008) | Alamyar et al., Immunome Research 8:1:2 (2012) |
| Program version listed by IMGT (2026-11-20) | V-QUEST 3.8.3 (4 September 2026) on its user guide | HighV-QUEST 1.9.10 (18 August 2026) on its portal page |
In practice, the 50-sequence limit is the dividing line most users meet first: a few clones from Sanger sequencing or a handful of antibody cDNAs fit V-QUEST, while a repertoire sequenced on an NGS platform belongs in a high-throughput pipeline. IMGT’s own HighV-QUEST page lists the 2012 Methods in Molecular Biology chapter on both tools and a 2013 Nature Communications paper on the HighV-QUEST approach to T cell receptor IMGT clonotypes and repertoire immunoprofiling. For the wet-lab side of repertoire work, see the CASRAI guides to TCR sequencing and NGS DNA sequencing workflows and outputs.
Where it matters in research and laboratory work
Antibody and receptor sequence annotation
Because every output follows the IMGT unique numbering, V-QUEST is a common route for assigning gene usage, counting somatic mutations against the closest germline allele and extracting the junction of a monoclonal antibody or T cell receptor clone. The tool’s mutation tables separate silent from non-silent changes and transitions from transversions, and it marks hotspot positions in the closest germline V gene, according to the 2008 paper. That information supports reporting of clone origin, comparison of related clones and checking of constructs.
Single-chain Fv constructs
An advanced functionality searches the submitted sequence for both V-domains of an scFv, provided both lie in the same orientation. Results then include one line per V-domain in the first ten CSV files and one line per scFv in the twelfth file. The functionality is described for nucleotide input; the guide says the scFv analysis is not yet available for cDNA sequences. For the construct itself, see the CASRAI guide to the scFv antibody.
Clinical-research subset assignment
Another advanced functionality assigns human IGH rearranged sequences to chronic lymphocytic leukaemia (CLL) stereotyped subsets #2 and #8, using criteria the guide tabulates: IGHV3-21 with IGHJ6 and a nine-amino-acid CDR3-IMGT pattern XX[D/E]XXXMDV for subset #2, and IGHV4-39 with IGHJ5, identity above 98% and a 19-amino-acid CDR3-IMGT pattern for subset #8. This is a research annotation feature of the tool; it is not a diagnostic and this page gives no clinical interpretation. For other subsets, the guide refers to ARResT/AssignSubsets.
Reporting and reproducibility
Papers that use the tool are asked to cite it. IMGT’s V-QUEST page lists the 2008 Nucleic Acids Research paper (PMID 18503082) and the 2011 Cold Spring Harbor Protocols article (PMID 21632778) as the citations for IMGT/V-QUEST, and the IMGT system papers of 2015 and 2022 for IMGT itself. Record the program version and reference directory release, which the Parameters output provides, because both change over time: the user guide lists a numbered reference directory release with its date, and the program version carries a date as well.
Common misunderstandings
“V-QUEST aligns any antibody sequence”
It aligns variable-region sequences it can number. Germline D and J genes, partially rearranged D-J genes and out-of-frame pseudogenes are outside its scope, and short or non-rearranged fragments may fail or return aberrant results.
“The closest allele is a fact about the sample”
The closest allele is relative to the reference directory set you chose. A different species option, strain option, the F+ORF versus in-frame pseudogene set, or comparison against allele *01 only, changes what the tool is comparing your sequence with. The result page recalls the selected parameters at the top so the run can be repeated.
“Junction results are returned for every sequence”
The guide states that IMGT/JunctionAnalysis results are not given for every sequence: they depend on the reference sequences found and on mutation counts staying within the limits set in the advanced parameters. The text version of the Synthesis view omits JunctionAnalysis altogether.
“The online tool is the right route for a repertoire”
The online V-QUEST limit is 50 sequences per submission. IMGT directs NGS-scale analysis to IMGT/HighV-QUEST, a separate portal with its own login.
“Spreadsheet output differs between the two tools”
For the eleven main CSV files the user guide says the files are identical to those from IMGT/HighV-QUEST, so scripts written against one tool’s CSV layout can be checked against the other’s.
Sources
- IMGT: IMGT/V-QUEST Documentation (user guide), checked 2026-11-20
- IMGT: IMGT/V-QUEST tool page (IMGT Index), checked 2026-11-20
- IMGT: IMGT/HighV-QUEST portal page, checked 2026-11-20
- PubMed (NCBI): Brochet, Lefranc and Giudicelli (2008), IMGT/V-QUEST: the highly customized and integrated system for IG and TR standardized V-J and V-D-J sequence analysis, checked 2026-11-20
Data: IMGT/V-QUEST default junction-analysis settings and last V codon by locus
Default parameters of the IMGT/V-QUEST online tool by receptor locus, compiled from the 'Parameters for IMGT/JunctionAnalysis' and 'Parameters for Detailed view' tables of the IMGT/V-QUEST user guide, read on 2026-11-20. Columns give the number of D genes allowed in the junction, the number of mutations accepted in the 3' V-region and 5' J-region and in the D-region, and the last V-region codon (IMGT numbering) used to score the alignment and identify the closest V gene and allele.
Period covered: 2026.
| Locus | D genes allowed in junction analysis (genes) | Accepted mutations in 3'V and 5'J regions (mutations) | Accepted mutations in D-region (mutations) | Last V-region codon used for alignment score (IMGT codon position) |
|---|---|---|---|---|
| IGH | 1 | 2 | 4 | 104 |
| IGK | not listed | 7 | NR | 109 |
| IGL | not listed | 7 | NR | 110 |
| TRA | not listed | 0 | NR | 104 |
| TRB | 1 | 0 | 0 | 104 |
| TRD | 3 | 0 | 0 | 104 |
| TRG | not listed | 0 | NR | 104 |
Sources
- IMGT/V-QUEST Documentation (user guide) (accessed 2026-11-20)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.