Skip to main content
v2026.11,986 entries · CC-BY 4.0

Jensen Medium (Lowenstein-Jensen, LJ): Composition and Variants

Jensen medium is Lowenstein-Jensen (LJ) medium for mycobacteria: components, glycerol, pyruvate and 5% NaCl variants, and published QC figures compared.

Written and maintained by CASRAI Editorial Board

Published

On this page

Jensen medium, properly Lowenstein-Jensen (LJ) medium, is a solid, egg-based culture medium used to isolate and grow Mycobacterium species, most often Mycobacterium tuberculosis. It combines whole egg, potato flour, mineral salts, asparagine and glycerol, is set by heat coagulation (inspissation) into slopes, and carries malachite green to suppress contaminating bacteria. It is the same medium whether a laboratory writes LJ medium, LJ media, Lowenstein-Jensen or Lowenstein Jensen.

What Lowenstein-Jensen medium is

LJ medium is a glycerated egg-potato medium. The Thermo Fisher (Remel) instructions for use describe the principle this way: the glycerol and egg mixture provide the fatty acids and protein that mycobacteria need for metabolism, and malachite green dye is added to inhibit other microorganisms and to act as a pH indicator. A TM Media product data sheet places it among the solid media for mycobacteria, which are either egg-based or agar-based, and states that of the egg-based media Lowenstein-Jensen is the most commonly used.

The medium exists because Mycobacterium tuberculosis is demanding. India’s national TB programme laboratory training manual notes that the organism has a generation time of 18 to 24 hours and will not grow on primary isolation on simple chemically defined media. The media that allow abundant growth are egg-enriched media with glycerol and asparagine (Lowenstein-Jensen) or agar media with bovine albumin (Middlebrook 7H10 and 7H11), and the same manual calls LJ the most widely used medium for tuberculosis culture.

Where the name comes from

Both the Remel instructions and the TM Media sheet give the same history. In 1931 Lowenstein formulated a medium for cultivating mycobacteria that contained congo red and malachite green dyes to partially inhibit a number of bacterial species. In 1932 Jensen modified it by altering the citrate and phosphate contents, eliminating congo red and increasing the malachite green concentration. The TM Media sheet adds that Gruft later modified the medium with two antimicrobial agents to increase selectivity; that is a separate, selective variant and not what an unqualified “LJ medium” label means.

Composition and the role of each component

The three documents read for this page agree on the mineral and nitrogen base per litre-scale batch: asparagine 3.6 g, potassium dihydrogen phosphate 2.4 g, magnesium sulphate 0.24 g and magnesium citrate 0.6 g. They differ in how they express the dye and in how much of the recipe they state at all, which is why the data table below sets them side by side instead of presenting one recipe.

  • Whole egg. Supplies protein and fatty acids, and is the component that solidifies on heating. All three documents use 1000 ml of egg preparation per batch.
  • Glycerol. Part of the egg-potato nutrient system in the Remel principle statement. The India manual states that with glycerol the medium favours M. tuberculosis. The TM Media sheet instructs not to add glycerol if bovine or other glycerophobic strains are to be cultured.
  • Asparagine and mineral salts. The nitrogen source and buffering and mineral salts in the base formula.
  • Malachite green. An inhibitor of most contaminants that survive specimen decontamination, and a pH indicator. The TM Media sheet describes the visible consequence: a blue zone indicates a pH decrease caused by gram-positive contaminants such as streptococci, yellow zones show dye destruction by gram-negative bacilli, and proteolytic contaminants digest the medium locally or completely.
  • Potato flour. Listed at 30.0 g in the Remel classical formula; it is part of the egg-potato base described as the medium’s principle.

Variants: plain LJ, pyruvate LJ and LJ with 5% NaCl

“LJ medium” on a label can hide three documented variants. The differences matter when a protocol, a purchase specification or a quality control record refers to the medium by name only.

Standard LJ with glycerol

The default for tuberculosis culture in the India manual. Glycerol favours M. tuberculosis.

LJ with sodium pyruvate (no glycerol)

For cultivating M. bovis, the India manual describes enriching LJ medium with 0.5% sodium pyruvate, omitting glycerol from the mineral salt solution and using 8.0 g of sodium pyruvate per 600 ml of mineral salt solution. The same manual describes inoculating two standard slopes per specimen and states that an additional pyruvate slope may be used to support M. bovis. Because the instruction is to omit glycerol, this variant is not interchangeable with the standard medium.

LJ with 5% NaCl

The Remel product is not a general isolation medium. It is a tube used with a sodium-chloride-free LJ control tube to differentiate slowly growing from rapidly growing mycobacteria on salt tolerance. According to the instructions, most rapid growers and Mycobacterium triviale grow on the salt-containing medium, some strains of M. flavescens may also grow, and the inability of M. chelonae subsp. chelonae to grow distinguishes it from the other members of the M. fortuitum complex. The classical formula lists 80.0 g of sodium chloride.

Variant Documented purpose Documented difference Source
Standard LJ Isolation and cultivation of mycobacteria; most widely used for tuberculosis culture Contains glycerol; favours M. tuberculosis India NTP manual; TM Media TM 2167
LJ with pyruvate Cultivation of M. bovis 0.5% sodium pyruvate in place of glycerol India NTP manual
LJ with 5% NaCl Differentiating slow from rapid growers by salt tolerance 5% sodium chloride; run with an NaCl-free LJ control tube Remel IFU 8518

Preparation and quality control figures that are published

The data table below compares the preparation and storage parameters stated by the Remel instructions, the TM Media data sheet and the India manual. Two cautions come straight from that comparison. First, the malachite green quantity is expressed three different ways (0.4 ml in the Remel classical formula, 0.4 g of dye dissolved in 20 ml of water in the TM Media sheet, and 20 ml of a 2% solution in the India manual), so a number copied from one document into another protocol is not safe. Second, coagulation is documented at 85 degrees C for 60 minutes by TM Media but 85 degrees C for 50 minutes by the India manual, which also states that egg media deteriorate when coagulation uses too high a temperature or runs too long.

The India manual describes inspissation as solidifying the medium, not sterilising it, since the medium has been prepared with sterile precautions. It describes coagulation going wrong in two visible ways: discolouration of the coagulated medium may be due to excessive temperature, and little holes or bubbles on the surface indicate faulty coagulation. It also describes a batch sterility check: after inspissation the batch is incubated at 35 to 37 degrees C for 24 hours, 5% of the slopes picked at random continue for 14 days to check for fungal sterility, and the contamination rate should not exceed 10%.

Quality control organisms named in manufacturer documents

Remel lists Mycobacterium flavescens ATCC 14474 as the positive control for the 5% NaCl medium and Mycobacterium kansasii ATCC 12478 as the negative control, each read at 2 weeks at 35 to 37 degrees C in 5 to 10% CO2. The TM Media sheet lists M. avium 25291, M. gordonae 14470, M. kansasii 12478, M. smegmatis 14468 and M. tuberculosis H37Rv 25618, inoculated at 50 to 100 CFU and read for good to luxuriant growth after 2 to 4 weeks. It describes H37Rv colonies as granular, rough, warty, dry and friable, with a final prepared-medium pH of 7.0 plus or minus 0.2 at 25 degrees C.

Incubation, reading and what colonies look like

The India manual describes incubation at 35 to 37 degrees C, an early look at 48 to 72 hours to detect gross contaminants, and then weekly examination up to 8 weeks, with negative cultures discarded after 8 weeks. It states that M. tuberculosis colonies are rough, crumbly and buff, described as breadcrumb or cauliflower-like, and that visible growth from smear-positive specimens usually takes 2 to 4 weeks and is never seen in less than 1 week. Remel’s 5% NaCl test uses a different, shorter-purpose protocol: caps loosened, 5 to 10% CO2, up to 4 weeks, examined weekly, and the control tube must show growth before a negative result is reported.

Where it matters for laboratories

Contamination is expected at a low rate

The India manual states that a proportion of cultures will always be contaminated by other organisms and that, as a general rule, a contamination rate of 2 to 3% is acceptable in laboratories that process fresh specimens; where processing is delayed beyond 3 days, culture losses from contamination may reach 5 to 10%. It adds that a laboratory with no contamination at all is probably using a decontamination method that kills too many tubercle bacilli, which raises the culture negativity rate. This is a different figure from the 10% batch sterility threshold above: one is a specimen-culture contamination rate, the other a manufacturing check on the medium.

Causes of excess negative cultures

Among the causes of increased negative cultures the manual lists delays in specimen processing, specimen quality, increased malachite green concentration, increased incubation temperature, increased inspissation time or temperature and low centrifugation. Two of those are properties of the medium itself, which is why the dye quantity and the coagulation settings are the parameters worth recording per batch.

Storage and handling

Remel notes that media containing malachite green are photosensitive and should not be exposed to light during storage, and that tubes should be tightly sealed before inoculation to avoid dehydration. The India manual stores dated, batch-numbered LJ slopes in the refrigerator for up to 4 weeks with the caps tightly closed. The TM Media dehydrated base is hygroscopic, kept dry and tightly closed at 25 to 30 degrees C away from direct sunlight, with a stated shelf life of 4 years under optimal conditions, and is not to be used if it shows contamination, discolouration or drying. The India manual specifies processing of specimens in a biosafety cabinet to avoid aerosols; see the CASRAI explainers on the biosafety cabinet and biosafety levels BSL-1 to BSL-4 for the containment framework, and culture media preparation for the general bench practice behind prepared media. For the wider discipline, see what is bacteriology; for a different class of microbiology medium used to hold specimens rather than grow them, see transport media in microbiology.

Common misunderstandings

  • “Jensen medium” is not a separate medium. It is a shortened name for Lowenstein-Jensen; Jensen’s 1932 changes to Lowenstein’s formula are the reason both names appear.
  • The recipe is not one fixed number set. Published documents express malachite green, glycerol and egg quantities differently and Remel notes its formula is adjusted as required to meet performance standards.
  • Inspissation is not sterilisation. The India manual says the heating step solidifies a medium prepared with sterile precautions.
  • Glycerol is not always wanted. It favours M. tuberculosis; for M. bovis the pyruvate variant omits it.
  • Zero contamination is not the goal. Per the India manual, none at all can indicate an overly harsh decontamination method.
  • LJ is not the only solid medium. The India manual names Middlebrook 7H10 and 7H11 agar as the alternative class.

Frequently asked questions

What is Lowenstein-Jensen (LJ) medium used for?

It is used to isolate and cultivate Mycobacterium species, and the India national TB programme manual calls it the most widely used medium for tuberculosis culture. It is also the base for the 5% NaCl variant used to differentiate slow and rapid growers.

Is Jensen medium the same as LJ medium?

Yes. Jensen medium, LJ media, LJ medium, Lowenstein Jensen and Lowenstein-Jensen medium all refer to the egg-based mycobacterial medium Lowenstein formulated in 1931 and Jensen modified in 1932.

Why does LJ medium contain malachite green?

Malachite green inhibits most non-mycobacterial contaminants and works as a pH indicator, so blue and yellow zones and local digestion of the medium signal contamination.

Why would glycerol be left out?

Glycerol favours M. tuberculosis, so the TM Media sheet advises not adding it for bovine or other glycerophobic strains and the India manual describes a pyruvate medium without glycerol for M. bovis.

How long are LJ cultures incubated?

The India manual describes weekly reading up to 8 weeks at 35 to 37 degrees C, with first growth from smear-positive specimens usually taking 2 to 4 weeks. The Remel 5% NaCl test runs up to 4 weeks.

What does 5% sodium chloride do in LJ medium?

It lets the laboratory differentiate slowly growing mycobacteria from rapidly growing ones by salt tolerance, read against a salt-free LJ control tube.

Sources

  • Thermo Fisher Scientific (Remel), instructions for use IFU8518, Lowenstein-Jensen (L-J) Medium w/ 5% NaCl, revision 13 February 2007. documents.thermofisher.com. Read 2026-11-15.
  • TM Media, product data sheet TM 2167, Lowenstein Jensen Medium Base (as per IP). tmmedia.in. Read 2026-11-15.
  • Central TB Division, Government of India, training manual on culture and drug susceptibility testing for M. tuberculosis. tbcindia.mohfw.gov.in. Read 2026-11-15.

Data: Lowenstein-Jensen medium: preparation, incubation and storage parameters stated in three documents

Side-by-side comparison of the quantities, coagulation settings, incubation conditions and storage statements given in a Remel 5% NaCl LJ instruction sheet, a TM Media LJ base data sheet and the Indian national TB programme laboratory manual. Values are transcribed as stated; 'Not stated' means the document gives no value.

Lowenstein-Jensen medium: preparation, incubation and storage parameters stated in three documents
ParameterRemel IFU8518 (LJ w/ 5% NaCl)TM Media TM 2167 (LJ base)India central TB Division manual
Asparagine (g)3.63.6 per litre3.6 per 600 ml mineral salt solution
Potassium dihydrogen phosphate (g)2.42.4 per litre2.4 per 600 ml mineral salt solution
Magnesium sulphate (g)0.240.24 per litre0.24 per 600 ml mineral salt solution
Magnesium citrate (g)0.60.6 per litre0.6 per 600 ml mineral salt solution
Glycerol12.0 mlAdded to the 600 ml base water; amount not stated; omit for bovine or glycerophobic strains12 ml per 600 ml mineral salt solution; omitted in the pyruvate variant
Malachite green0.4 ml (classical formula)0.4 g dissolved in 20 ml sterile distilled water20 ml of a 2% solution (2.0 g dye per 100 ml water)
Whole egg (ml)10001000 (egg emulsion)1000 (homogenised whole eggs, 25-30 eggs)
Sodium chloride (g)80.0Not statedNot stated
Dispensed volumeNot stated5 ml in 25 ml McCartney bottles6-8 ml in sterile universal containers
Coagulation (inspissation)Not stated85 C for 60 minutes85 C for 50 minutes, slanted position
Incubation conditions35-37 C, 5-10% CO2, caps loosened, up to 4 weeks35-37 C, 5-10% CO2, 2-4 weeks (QC reading)35-37 C, read at 48-72 h then weekly up to 8 weeks
Storage statementProtect malachite green media from light; seal tubes tightly before inoculationPowder dry at 25-30 C away from sunlight, shelf life 4 years under optimal conditionsDated, batch-numbered slopes in refrigerator up to 4 weeks, caps tight

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Jensen Medium (Lowenstein-Jensen, LJ): Composition and Variants

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →