Laemmli buffer is the SDS-containing sample buffer used to prepare protein samples for SDS-PAGE. It is built from SDS, a reducing agent (2-mercaptoethanol or DTT), glycerol, Tris-HCl at pH 6.8 and a tracking dye (bromophenol blue). It is normally made as a concentrated stock, such as 2x, and mixed with the sample so the final mixture is 1x before heating and loading. The name is a family label, not one fixed recipe: the pH 6.8 Tris, SDS and glycerol are constant, while concentrations and dye amounts differ between sources.

Definition and scope

The name comes from Ulrich K. Laemmli, whose 1970 paper in Nature, “Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4” (Nature 227, 680-685, published August 1970; doi:10.1038/227680a0), made the discontinuous SDS polyacrylamide gel system standard. In everyday lab usage “Laemmli buffer” or “Laemmli sample buffer” means the sample (loading) buffer used with that system. It is distinct from the Tris-glycine-SDS running (electrode) buffer that fills the tank; the two are often confused because both are associated with the same gel method. For the gel system itself, see our guide to SDS-PAGE protein gel electrophoresis.

“Sample buffer” and “loading buffer” are used interchangeably for this reagent in protein work. In this page the term always means the reducing SDS sample buffer unless it is stated to be non-reducing (the same buffer made without 2-mercaptoethanol or DTT).

What each component does

Bitesize Bio’s explainer on Laemmli buffer (read 2026-11-12) describes the function of each ingredient as follows.

  • SDS denatures proteins by disrupting non-covalent bonds and coats them with negative charge, so they migrate through the gel by size rather than by their own charge.
  • Reducing agent (2-mercaptoethanol or DTT) breaks the disulfide bonds that SDS cannot disrupt. DTT is less stable than 2-mercaptoethanol and needs to be added again from time to time. Our guides to 2-mercaptoethanol and DTT cover the reagents themselves.
  • Glycerol makes the sample denser than the running buffer so that it sinks into the well instead of diffusing away.
  • Tris-HCl, pH 6.8 keeps the buffer chemically stable, inhibits some enzymes including proteases, and matches the pH of the stacking gel, which helps give sharp bands.
  • Bromophenol blue colours the sample so it can be seen while loading, and its dye front shows how far the run has progressed.

Laemmli buffer composition: 2x, 3x and 5x

The data table below this article lists the composition of 2x, 3x and 5x Laemmli sample buffer as given by Bitesize Bio (read 2026-11-12). The three stocks scale linearly: 3x contains 1.5 times and 5x contains 2.5 times each component of the 2x stock.

How to read the concentrations (calculation, not a quoted value)

A concentrated stock is diluted into the sample until the buffer is 1x. Mixing 2x buffer 1:1 with sample halves every value in the 2x column, giving 1x values of 2% w/v SDS, 5% v/v 2-mercaptoethanol, 10% v/v glycerol, 62.5 mM Tris-HCl and 0.0025% w/v bromophenol blue. This is arithmetic from the published 2x figures. It is consistent with Bio-Rad’s guidance in its protein sample preparation bulletin (Bulletin 6194, read 2026-11-12) to use “5% (~100 mM) 2-mercaptoethanol” in sample buffer, since 5% is the 1x level of a 2x stock containing 10%.

Why published recipes differ

Because “Laemmli buffer” is a family of formulations, two correct recipes can differ in bromophenol blue amount, in whether glycerol is expressed as % v/v or % w/v (Bitesize Bio gives both: 20% v/v or 25.2% w/v for 2x), and in whether the reducing agent is already in the stock. The Bio-Rad bulletin recommends leaving it out of the stock and adding it fresh, so a commercial “2x Laemmli” bottle and a lab-made stock may not be interchangeable without checking what is already in it.

Reducing agents: when to add them

Bio-Rad’s bulletin (Bulletin 6194, read 2026-11-12) gives the following preparation points for SDS-PAGE sample buffer.

  • Prepare the sample buffer without reducing agent, then aliquot it and store it at -70 °C.
  • Prepare the reducing agent fresh and add it to the sample buffer immediately before use.
  • Use either 5% (about 100 mM) 2-mercaptoethanol or 5-10 mM DTT in the sample buffer.

Bitesize Bio states that a concentrated Laemmli buffer can be stored at 4 °C for at least a year, and that DTT, if used in place of 2-mercaptoethanol, is less stable and should be re-added periodically. The two sources therefore agree that DTT is the less stable reducing agent and that the reducing agent is the component to manage carefully. They differ on storage temperature, and the Bio-Rad advice applies to a buffer stored without the reducing agent. Where a laboratory has its own validated SOP, follow it; the two sources are not a substitute for one.

A reducing buffer is needed when disulfide-linked subunits should be separated; leaving the reducing agent out gives a non-reducing sample buffer. Hazard handling for 2-mercaptoethanol (it is a hazardous reagent) is covered in our 2-mercaptoethanol guide and the safety data sheet from your supplier.

Heating, dilution and protein concentration

The same Bio-Rad bulletin states the following for sample preparation.

  • Dissolve dry protein samples directly in 1x sample buffer, and prepare other samples so that the final sample buffer concentration is 1x.
  • Incubate samples in sample buffer at 95 °C for 5 minutes, or at 70 °C for 10 minutes, after adding the sample buffer, for more complete disruption of molecular interactions.
  • The final protein concentration for one-dimensional electrophoresis should preferably be not less than 0.5 mg/ml, consistent with the sensitivity of the detection method.
  • For samples already in Laemmli sample buffer, a protein assay that tolerates detergent is needed; the bulletin names the DC and RC DC protein assays, which it says tolerate up to 10% detergent.
  • Use extracts immediately or aliquot them and store them at -70 °C to avoid freeze-thaw cycles.

Because the sample is already in detergent-containing buffer, the bulletin’s advice is to pick a protein assay that tolerates the chemicals present; it names the DC and RC DC assays for this case.

Heating also interacts with buffer chemistry. Our guide to Bis-Tris covers a manufacturer statement on how the pH of Tris-glycine Laemmli buffer changes on heating and why Bis-Tris based LDS sample buffers are formulated differently. Do not assume a Laemmli buffer and an LDS sample buffer can be swapped between gel chemistries.

Comparison: what the two readable manufacturer and methods sources say

Question Bitesize Bio explainer Bio-Rad Bulletin 6194
Reducing agent level 10% v/v BME in 2x stock (so 5% at 1x by calculation) 5% (~100 mM) 2-mercaptoethanol, or 5-10 mM DTT
Is the reducing agent in the stock? Yes, in the listed recipe No: add fresh immediately before use
Storage of buffer Concentrated buffer at 4 °C for at least a year Without reducing agent, aliquoted at -70 °C
Heating guidance Not given 95 °C for 5 min or 70 °C for 10 min
Final working strength 2x, 3x or 5x stocks 1x in the sample

Where it matters for lab supply decisions

Laemmli buffer is bought ready-made as a concentrated stock or made in-house. The practical point from the sources above is to read exactly what a stock contains: concentration (2x, 4x, 5x), whether a reducing agent is already included, and the gel chemistry it is intended for. Reducing agents are then added or sourced separately according to the lab’s SOP. This page makes no recommendation of any brand or product.

Common misunderstandings

  • Laemmli sample buffer is not the running buffer. The sample buffer goes into the sample; the Tris-glycine-SDS running buffer fills the tank.
  • There is no single official recipe. The 1970 paper describes the discontinuous SDS system; published sample buffer recipes are formulations in the same family.
  • A 1x sample is not the same as a 1x stock. Stocks are diluted into the sample; the working strength is 1x.
  • Reducing and non-reducing buffers look the same. Check the label for 2-mercaptoethanol or DTT before loading.

Frequently asked questions

What is Laemmli buffer?

Laemmli buffer is the SDS, glycerol, Tris-HCl (pH 6.8) and bromophenol blue sample buffer, usually with 2-mercaptoethanol or DTT, that denatures and reduces protein samples before SDS-PAGE. It is named for U. K. Laemmli’s 1970 Nature paper on the discontinuous SDS gel system.

What is the Laemmli buffer recipe or composition?

One published 2x composition (Bitesize Bio, read 2026-11-12) is 4% w/v SDS, 10% v/v 2-mercaptoethanol or DTT-equivalent reducing agent, 20% v/v glycerol, 125 mM Tris-HCl pH 6.8 and 0.005% w/v bromophenol blue. See the data table for the 3x and 5x versions. Recipes vary between sources, so use your laboratory’s validated SOP.

What is the difference between sample buffer and loading buffer?

For protein gels the terms are used for the same reagent. The Tris-glycine-SDS running buffer in the tank is a different solution. For general buffer preparation practice, see the buffer and solution preparation guide.

How long and at what temperature should samples in Laemmli buffer be heated?

Bio-Rad’s Bulletin 6194 gives 95 °C for 5 minutes or 70 °C for 10 minutes after adding the sample buffer.

Where does this fit in a western blot workflow?

Sample preparation in Laemmli buffer precedes gel loading; the downstream steps are in our western blot protocol basics guide.

Sources

Data: Composition of 2x, 3x and 5x Laemmli sample buffer

Component concentrations of concentrated Laemmli sample buffer stocks (2x, 3x, 5x) as published in a methods explainer, with the corresponding 1x working values calculated by dividing by the stated stock factor.

Composition of 2x, 3x and 5x Laemmli sample buffer
Component2x stock3x stock5x stock1x working value from 2x (calculated)Unit
SDS (w/v)46102%
2-Mercaptoethanol or DTT-equivalent reducing agent (v/v)1015255%
Glycerol (v/v)20305010%
Tris-HCl, pH 6.8125187.5312.562.5mM
Bromophenol blue (w/v)0.0050.00750.01250.0025%

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Laemmli Buffer: Composition, 2x Recipe and Use

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →