Large Bore IV: Definition, Gauge Cut-Off and What Limits Flow

What a large bore IV is, the 18 gauge cut-off attributed to ATLS, and why connectors and stopcocks also affect flow.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product information only, not medical advice. It does not describe how to place or use a catheter.

A large bore IV is a peripheral intravenous catheter with a wide internal diameter, chosen where fluids, blood products or medications must run quickly. A 2025 narrative review attributes this definition to the Advanced Trauma Life Support (ATLS) guidelines: a gauge of 18 or larger, where a lower number means a larger diameter. Flow also depends on the connectors and tubing in the line, not only the catheter.

What is a large bore IV?

The BJA Open review “Effective utilisation of rapid infusion catheters in perioperative care” (2025) states that the American College of Surgeons’ ATLS guidelines define a large-bore peripheral IV catheter (PIVC) as one with a gauge size of 18 Ga or larger, with lower numbers indicating a larger internal diameter. The same review says large-bore cannulas allow rapid administration of fluids, blood products and medications in settings such as trauma resuscitation, major surgery and high-volume transfusion. This page reports that statement as the review’s account of ATLS.

Definition and scope: the 18 gauge rule

Gauge numbering runs backwards: 14 is wider than 18, and 18 is wider than 22. Under the definition above, 18 gauge is the smallest size that still counts as large bore. Other usage differs: the site’s gauge guide, for example, describes 14 and 16 gauge as the standard trauma-bay and operating-room sizes, so a spec sheet or protocol that says “large bore” should be read with its own cut-off in mind. For the size-by-colour reference, see the site’s IV catheter gauge selection guide; for converting between French and millimetres, see French to mm conversion.

Large bore IV catheters and large-bore peripheral IV access

“Large bore IV catheter”, “large bore catheter” and “large bore peripheral IV” describe the same idea: a short peripheral catheter at or above the size threshold. The review distinguishes these from the rapid infusion catheter (RIC), a large-bore IV sheath that it describes as available in two sheath sizes (7 Fr and 8.5 Fr). A RIC is a different device from a standard peripheral catheter. For the basics of the device itself, see what an IV catheter is.

“2 large bore IV” and “two large-bore IVs”

These phrases are simply a count of large-bore lines. How many lines a given patient or protocol calls for is a clinical decision made by the treating team and is outside the scope of this page.

Large bore vs small bore

The difference is the internal diameter of the catheter, expressed as a gauge. The review also cautions that not all large-bore PIVCs are created equal: catheters of the same nominal gauge can differ, with some achieving substantially faster flow than others. Gauge alone is therefore a starting point, not a performance guarantee.

What limits flow besides the catheter

The catheter is one component of the path. A 2026 bench study in Military Medicine (Ferguson et al., 2026) used a 16 gauge catheter with tubing as the control and measured flow with added connectors. Reported values:

Condition (16 gauge catheter and tubing) Gravity flow (mL/s) Pressurized, 300 mmHg (mL/s)
Control, no added connector 1.19 ± 0.05 3.46 ± 0.072
With needleless connector 0.95 ± 0.018 (P<.0001) 3.10 ± 0.048
With high-flow 2-way stopcock 1.21 ± 0.05 (no significant reduction) 3.42 ± 0.048 (no significant reduction)

This was an in vitro study, so it shows how components can limit flow on a bench, not what happens in a patient. The practical point for anyone reading a spec sheet is to check each part of the line: the catheter, any connector or stopcock, and the tubing. See what IV extension tubing is for the tubing side.

Regulatory identity

In the United States, 21 CFR 880.5200 defines an intravascular catheter as a device that consists of a slender tube and any necessary connecting fittings, intended for short-term use of less than 30 days, for example to draw blood, monitor blood pressure or administer fluids. It is classified as Class II (performance standards). The regulation does not use the term “large bore” and sets no gauge threshold.

Where it matters for labs, clinics and supply decisions

  • Confirm which gauge cut-off a protocol or product page means by “large bore”; the ATLS-attributed definition is 18 gauge or larger, and other usages differ.
  • Treat a RIC or sheath-type device as a separate product category from a standard peripheral catheter.
  • Check connectors and stopcocks as well as the catheter when flow rate matters; bench data show a needleless connector reduced flow in one test setup.
  • Confirm the product is described as an intravascular catheter under 21 CFR 880.5200 where regulatory status is relevant.

Common misunderstandings

  • A bigger number means a bigger catheter. The opposite: a lower gauge number is a larger diameter.
  • Every 18 gauge catheter flows the same. The review notes large-bore catheters are not all equal.
  • Only the catheter limits flow. Connectors and other line components can reduce flow, as the bench study shows.
  • “Large bore” is a regulatory term. It is a clinical usage; the CFR classification covers intravascular catheters generally.

FAQ

What is a large bore IV?

A peripheral IV catheter with a wide internal diameter. A 2025 review attributes to ATLS a definition of 18 gauge or larger, where lower numbers are larger.

Is 18 gauge large bore?

Under the ATLS-attributed definition, yes, 18 gauge is the smallest size that qualifies. Other usage differs, and some settings treat only 14 or 16 gauge as large bore.

What is a large bore peripheral IV used for?

The review describes rapid administration of fluids, blood products and medications, for example in trauma resuscitation, major surgery and high-volume transfusion.

Sources

Checked 1 November 2026.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Large Bore IV: Definition, Gauge Cut-Off and What Limits Flow

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →