Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthMedical & Research SuppliesReagents, PPE & instruments — chain-of-custody documented.Fast, traceable sourcing built for regulated research environments, from bench consumables to instrumentation.Shop lac.us CodeCASRAIlac.us

Lary Tube Sizes: Provox LaryTube Diameters, Lengths and Codes

Read a Provox LaryTube code such as 8/36, see every diameter, length and model combination, and what the manufacturer says about choosing a size.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product information, not medical advice. A laryngectomy tube is sized and prescribed by a clinician. This page decodes the size codes on one manufacturer’s tubes, the Atos Medical Provox LaryTube, so you can read a code such as 8/36 and match it to a model. For care and handling, see what a laryngectomy tube is and how it is used safely.

Short answer: a Provox LaryTube code has the form diameter/length. Diameter comes in four designations (8, 9, 10 and 12) and length in three sizes (27, 36 and 55 mm). That gives 12 standard sizes, plus 8 with-ring and 8 fenestrated sizes sold only in 36 and 55 mm, 28 catalogue sizes in all. Searches for “larytube sizes” and “lary tube sizes” lead to this same chart.

LaryTube size chart (diameter x length x model)

Reference numbers (REF) below are the ones in the manufacturer’s product information sheet for the Provox LaryTube (document PF011-01-TechInfo, edition 2.0). A dash means that combination is not listed.

Code (diameter/length) Standard REF With Ring REF Fenestrated REF
8/27 7601 – –
8/36 7602 7624 7637
8/55 7603 7625 7638
9/27 7605 – –
9/36 7606 7626 7640
9/55 7607 7627 7641
10/27 7609 – –
10/36 7610 7628 7643
10/55 7611 7629 7644
12/27 7613 – –
12/36 7614 7630 7646
12/55 7615 7631 7647

The product information sheet also carries a second reference list whose numbers end in “FR” (for example 7609FR). Use the list that matches your market and your product’s labelling; the two lists are not interchangeable. Always check your product’s labelling for the exact code and REF before relying on this chart.

How to read a code like 8/36

The manufacturer names its tubes “Provox LaryTube D/L”: the first number is the diameter designation and the second is the length in millimetres. So 8/36 is diameter designation 8, length 36 mm. The instructions for use (manual 90734, 2022-03-14) give the lengths in mm but list the diameters only as the numbers 8, 9, 10 and 12, with no unit. Do not convert a designation into millimetres yourself; a figure for the inner diameter has to come from the manufacturer’s own labelling.

Who chooses the size

Choosing and fitting a size is a clinical task, so this page gives no measuring or fitting steps. The manufacturer’s instructions for use state that the clinician can use a Provox LaryTube Sizer Kit, which contains samples (“sizers”) of the commercially available tubes, to help choose which sizes to prescribe. The product information sheet describes the tube as prescription only.

What a wrong size can do

The instructions for use warn that, if a tube is not an appropriate size, a tube that is too wide, too narrow, too long or too short may cause tissue damage, bleeding or irritation, and may make voice production harder. A tube that is too narrow may cause the stoma to shrink.

Standard, ring and fenestrated availability

  • Standard: all 12 sizes, including the only 27 mm lengths. Sold with or without a voice prosthesis in use, held with a TubeHolder or LaryClip.
  • With Ring: 8 sizes, 36 and 55 mm only. The Ring is a silicone part that, per the instructions for use, is used with Provox Adhesive.
  • Fenestrated: 8 sizes, 36 and 55 mm only, intended for voice prosthesis users, with a TubeHolder or LaryClip.

All three are silicone and supplied non-sterile for a single patient, according to the product information sheet.

Common mix-ups

Is a laryngectomy tube size the same as a tracheostomy tube size?

No. A tracheostomy tube is a different device with its own sizing system; see tracheostomy tube sizes and what a tracheostomy tube is. Do not use one device’s size to pick the other.

Is a LaryTube the same as a LaryButton?

No. The LaryButton is a separate Atos product with its own sizes. Check the product name on your labelling to see which one you have.

Is the diameter number in millimetres?

The manufacturer’s documents give the diameter as a designation (8, 9, 10, 12) without a unit, while lengths are in mm. Treat the two numbers in a code as different kinds of value.

Where do an HME or stoma cover fit in?

They are separate accessories. See laryngectomy HMEs and stoma covers.

FAQ

What sizes do Provox LaryTubes come in?

Four diameter designations (8, 9, 10, 12) and three lengths (27, 36, 55 mm), per the manufacturer’s instructions for use. Ring and fenestrated versions are listed only in 36 and 55 mm.

How many LaryTube sizes are there in total?

Twenty-eight in the product information sheet: 12 standard, 8 with Ring and 8 fenestrated.

Who decides which size to use?

A clinician. The manufacturer describes a Sizer Kit for the clinician’s use when choosing sizes to prescribe, and lists the tube as prescription only.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Lary Tube Sizes: Provox LaryTube Diameters, Lengths and Codes

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →