Written and maintained by CASRAI Editorial Board
Published
On this page
Long-read sequencing reads individual DNA or RNA molecules that are thousands to millions of bases long, typically about 10 kb to more than 1 Mb, where short-read sequencing reads fragments of roughly 150 to 300 bases. Long reads span repeats, structural variants and full-length transcripts that short reads cannot resolve, while short reads remain cheaper per base and more accurate per read.
Short answer: long-read versus short-read sequencing
The two approaches answer different questions. Short-read sequencing (the Illumina model) produces enormous numbers of fragments of about 150 to 300 bases with accuracy above 99.9% per base. Long-read sequencing (PacBio and Oxford Nanopore) produces fewer, much longer reads, so a single read can cross a repeat, a rearrangement or an entire RNA transcript. Which one a lab needs depends on the variant class, the sample quality, the error profile it can tolerate and the compute available to analyse the data. The comparison table further down this page brings the sourced figures together; the data table below the article lists the same ranges with their sources.
What is long-read sequencing?
Long-read sequencing, also called third-generation sequencing, determines the order of bases on DNA or RNA molecules that have not been chopped into short pieces first. A 2020 review in Nature Reviews Genetics by Logsdon, Vollger and Eichler describes long reads as ranging from about 10 kb to more than 1 Mb, and two commercial platform families dominate: Pacific Biosciences (PacBio) single-molecule real-time sequencing and Oxford Nanopore Technologies (ONT) nanopore sequencing. Oxford Nanopore’s own platform page states read lengths from 20 to 4,000,000 bases and says native DNA and RNA can be analysed directly, with real-time basecalling in its MinKNOW software.
The reason read length matters is the genome itself. Logsdon and colleagues report that reads under 300 bases are too short to detect more than 70% of human genome structural variation, and that more than 15% of the human genome (centromeres, telomeres and segmental duplications) is inaccessible to short reads. In one comparison they cite, short-read data missed 47% of deletions and about 78% of insertions that long reads detected.
PacBio: CLR and HiFi reads
PacBio produces two data types. Continuous long reads (CLR) have a single-pass accuracy of roughly 85% to 92%. Circular consensus (HiFi) reads read the same molecule repeatedly and collapse the passes into one consensus; the 2020 review calls HiFi “the first data type that is both long (greater than 10 kb) and highly accurate (greater than 99%)”. A 2025 review in Diagnostics by Moustakli and colleagues gives HiFi read lengths of 10 to 25 kb with accuracy above 99.9% (Q30 to Q40). For an alignment-focused walkthrough of HiFi data, see the CASRAI guide to PacBio DNA sequencing.
Oxford Nanopore reads
Nanopore sequencing passes a single molecule through a protein pore and reads the electrical signal. Because it needs no amplification step, long molecules survive intact: reads can exceed 1 Mb, and the Logsdon review reports that ultra-long nanopore runs yield roughly 0.5 to 2 Gb per flow cell on MinION and GridION devices. The same review gives typical accuracy of 87% to 98%; Moustakli and colleagues tabulate 98% to 99.5%, with typical reads of 20 to 100 kb. The two ranges come from different papers and different chemistry generations, so quote the paper and year rather than a single figure. Device details are in the CASRAI guide to Oxford Nanopore sequencing.
What is short-read sequencing?
Short-read sequencing fragments DNA, reads each fragment from its ends and reconstructs the sequence computationally by alignment or assembly. According to the Logsdon review, Illumina short reads are more than 99.9% accurate and inexpensive, which is why short-read platforms became the default for resequencing, exome work and expression counting. Moustakli and colleagues give the typical read length as 150 to 300 bp. The limit is not accuracy but context: a 150 bp read that falls inside a repeat can map to many places, so the technique has trouble with repetitive and duplicated regions and cannot by itself say which variants sit on the same chromosome copy. The CASRAI guides to next-generation DNA sequencing and Illumina versus Nanopore cover the short-read workflow and the platform trade-offs.
How the platforms compare
| Feature | Short-read (Illumina) | PacBio HiFi | Oxford Nanopore |
|---|---|---|---|
| Typical read length | 150 to 300 bp (Moustakli 2025) | 10 to 25 kb (Moustakli 2025) | 20 to 100 kb typical, above 1 Mb possible (Moustakli 2025); 20 to 4,000,000 bases stated by the manufacturer |
| Accuracy as reported | Above 99.9% (Logsdon 2020) | Above 99% (Logsdon 2020); above 99.9%, Q30 to Q40 (Moustakli 2025) | 87% to 98% (Logsdon 2020); 98% to 99.5% (Moustakli 2025) |
| Detects structural variation | Under 300 base reads miss more than 70% of structural variation (Logsdon 2020) | Spans most structural variants; HiFi-only assemblies reach contig N50 above 20 Mb (Logsdon 2020) | Spans structural variants; ultra-long reads help with repeats (Logsdon 2020) |
| Native base modifications | Requires chemical conversion such as bisulfite | Detected directly (Logsdon 2020) | Detected directly, including RNA methylation (Logsdon 2020; De Paoli-Iseppi 2021) |
| Main practical limit | Cannot resolve repeats or phase variants on its own | Lower throughput per run than short-read; needs high-quality input DNA | Read length limited by high-molecular-weight DNA extraction; higher homopolymer errors than short reads |
The sourced numbers are one half of the picture. The other half is what produced them: the reported accuracy ranges depend on the chemistry and basecaller of the year in which a paper was written, so treat any figure on this page as a dated literature value, not a specification for the kit on your bench.
Long-read RNA sequencing
Long-read RNA sequencing sequences complete transcripts rather than short fragments of them. De Paoli-Iseppi, Gleeson and Clark (Frontiers in Molecular Biosciences, 2021) explain that short reads cannot determine which full-length alternative isoforms are being expressed, because a short read rarely covers more than one splice junction. Long reads can show an isoform from its start to its end in one read.
Iso-Seq, cDNA and direct RNA
PacBio’s Iso-Seq method sequences full-length cDNA with circular consensus, giving HiFi-quality reads with an error rate below 1%. Nanopore offers two routes: sequencing amplified or unamplified cDNA, or direct RNA sequencing, in which the native RNA molecule is read without conversion, which also lets methylation on the RNA be detected. The review reports nanopore reads of more than 2 Mb and notes there is no known length limit.
| Throughput figure (De Paoli-Iseppi 2021) | Reported value |
|---|---|
| Short-read RNA-seq, bulk sample | 30 to 50 million reads |
| PacBio Sequel II, one run | Up to about 4 million HiFi reads |
| Nanopore PromethION, one flow cell | More than 50 million reads |
These numbers explain a practical rule: short reads count expression with more depth per sample, long reads define which isoforms exist. The same review reports that 30% to 60% of isoforms found in long-read studies were not in existing annotations, which is why long-read RNA data is often used to improve annotation rather than to replace expression counting. Its limits are the higher error rates, which affect splice-site calls, plus truncated reads, PCR bias and chimeric cDNA; the authors point to tools such as FLAIR and SQANTI and to unique molecular identifiers (UMIs) as mitigations. If you work at single-cell resolution, the single-cell RNA sequencing guide covers the short-read-based workflow that long-read methods are being added to.
Where long-read sequencing matters for labs
The sources point to a short list of situations in which read length is worth its costs.
- Structural variants and repeats. Repeat expansions, large insertions and deletions and rearrangements are the variant classes short reads miss most often (Logsdon 2020).
- Phasing and assembly. Long reads separate the two haplotypes and produce more contiguous assemblies; Logsdon and colleagues note the CHM13 telomere-to-telomere assembly has 590 contigs against 998 for GRCh38.
- Isoform discovery. Full-length transcripts and unannotated isoforms (De Paoli-Iseppi 2021).
- Epigenetic marks without conversion. Base modifications are read from the native molecule, without bisulfite treatment (Logsdon 2020).
Practical constraints to plan around
Three constraints recur in the literature. First, input quality: nanopore read length is limited by how much high-molecular-weight DNA the extraction preserves, so a long-read project begins with the extraction method, not the instrument. Second, error profile: homopolymer errors are higher on CLR and nanopore data, and Moustakli and colleagues note that residual errors complicate small-variant calling. Third, analysis: the same authors describe long-read pipelines as computationally heavy and, in clinical settings, not yet standardised, so pipelines are not interchangeable between platforms. Cost also differs: Logsdon and colleagues reported higher cost per gigabase for long reads in 2020, and Moustakli and colleagues give a per-sample whole-genome range of USD 500 to USD 1,500 for long reads; both are dated literature figures, not current prices, and costs have moved since. Hybrid designs that combine short-read depth with long-read contiguity are a common response; coverage planning for either is explained in the guide to depth versus breadth of coverage.
Common misunderstandings
“Long reads are inaccurate”
This was a fair description of early single-pass data, with PacBio CLR around 85% to 92%. It no longer describes HiFi reads, which Logsdon and colleagues put above 99% and Moustakli and colleagues above 99.9%. Nanopore accuracy is reported lower, at 87% to 98% in the 2020 review and 98% to 99.5% in the 2025 table.
“Long reads replace short reads”
The sources describe them as complementary. Short reads give higher per-read accuracy, more reads per sample and lower cost per gigabase in the 2020 comparison; long reads give context. Many projects use both.
“Long-read RNA-seq just counts genes better”
Its main contribution is isoform structure, not expression depth. At 30 to 50 million short reads against about 4 million HiFi reads per run, short reads still have the depth advantage for counting.
“Any DNA extraction will do”
Read length is bounded by the length of the molecules loaded. A protocol that shears DNA to a few kilobases cannot deliver reads in the hundreds of kilobases.
Frequently asked questions
What is long-read sequencing?
It is sequencing that reads DNA or RNA molecules about 10 kb to more than 1 Mb long in a single read, using PacBio or Oxford Nanopore instruments, so that repeats, structural variants and full-length transcripts can be read across (Logsdon et al., 2020).
What is short-read sequencing?
It is sequencing that reads fragments of roughly 150 to 300 bases, typically on Illumina instruments, with accuracy above 99.9% per base, and reconstructs the genome by alignment or assembly.
What is long-read RNA sequencing?
It is RNA sequencing that reads full-length transcripts in one read, through PacBio Iso-Seq, nanopore cDNA sequencing or nanopore direct RNA sequencing, so alternative isoforms can be identified directly (De Paoli-Iseppi et al., 2021).
Is long-read sequencing more accurate than short-read sequencing?
Not per base, in general. Short reads are above 99.9% accurate; PacBio HiFi is above 99% to above 99.9% depending on the source; nanopore ranges are reported between 87% and 99.5%. Long reads are more informative about structure, not more accurate base by base.
Can long reads detect DNA or RNA modifications?
Yes. Both nanopore and PacBio can detect base modifications directly on the native molecule without bisulfite conversion, and nanopore direct RNA sequencing can detect RNA methylation.
Do I need special DNA extraction for long-read sequencing?
For the longest nanopore reads, yes: read length is limited by the quality of high-molecular-weight DNA, according to the 2020 review.
Sources
- Logsdon GA, Vollger MR, Eichler EE. Long-read human genome sequencing and its applications. Nat Rev Genet 2020;21(10):597-614. https://pmc.ncbi.nlm.nih.gov/articles/PMC7877196/ (read 2026-11-14)
- Moustakli E, et al. Long-Read Sequencing and Structural Variant Detection. Diagnostics (Basel) 2025;15(14):1803. https://pmc.ncbi.nlm.nih.gov/articles/PMC12293859/ (read 2026-11-14)
- De Paoli-Iseppi R, Gleeson J, Clark MB. Isoform Age: Splice Isoform Profiling Using Long-Read Technologies. Front Mol Biosci 2021;8:711733. https://pmc.ncbi.nlm.nih.gov/articles/PMC8364947/ (read 2026-11-14)
- Oxford Nanopore Technologies, platform technology page. https://nanoporetech.com/platform/technology (read 2026-11-14)
Data: Long-read and short-read sequencing: read length and reported accuracy by technology
Read-length and accuracy ranges for short-read, PacBio HiFi and Oxford Nanopore sequencing, compiled from two peer-reviewed reviews (2020, 2025) and the manufacturer's platform page. Ranges differ between papers and chemistry generations.
Period covered: 2020/2025.
| Technology | Read length | Reported accuracy | Source |
|---|---|---|---|
| Short-read (Illumina) | 150 to 300 bp | Above 99.9% | Moustakli 2025 (length); Logsdon 2020 (accuracy) |
| PacBio HiFi | 10 to 25 kb | Above 99% (Logsdon 2020); above 99.9%, Q30-Q40 (Moustakli 2025) | Logsdon 2020; Moustakli 2025 |
| PacBio CLR | About 10 kb to above 1 Mb (long reads in general) | About 85% to 92% single-pass | Logsdon 2020 |
| Oxford Nanopore | 20 to 100 kb typical (Moustakli 2025); 20 to 4,000,000 bases stated by manufacturer | 87% to 98% (Logsdon 2020); 98% to 99.5% (Moustakli 2025) | Logsdon 2020; Moustakli 2025; Oxford Nanopore platform page |
Sources
- Long-read human genome sequencing and its applications (Nat Rev Genet 2020) (accessed 2026-11-14)
- Long-Read Sequencing and Structural Variant Detection (Diagnostics 2025) (accessed 2026-11-14)
- Oxford Nanopore Technologies platform technology (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.