Skip to main content
v2026.11,986 entries · CC-BY 4.0

Lung-on-a-Chip: What It Is, How It Works and What It Models

Lung-on-a-chip explained: how the alveolar-capillary interface, air-liquid culture and cyclic stretch work, and what published studies report.

Written and maintained by CASRAI Editorial Board

Published

On this page

A lung-on-a-chip is a microfluidic cell-culture device that reconstructs a small functional unit of the human lung, usually the air-facing epithelium and the blood-facing endothelium separated by a thin porous membrane, and moves the cells through breathing-like cyclic stretch and blood-like channel flow. Researchers use it as an in vitro model of lung responses to particles, pathogens and drugs, and it is one of the best-known organ-on-a-chip formats.

Definition and scope

Organ-on-a-chip devices are described in the research literature as microfluidic systems that mimic the cellular architecture and physiological environment of an organ. A review titled “Lung-on-a-chip: the future of respiratory disease models and pharmacological studies” (PubMed 31906727) reports that lung models of this kind give a more accurate reflection of the organ than conventional models.

A 2024 mini review in Frontiers in Lab on a Chip Technologies (Park, Woo and Cho, doi 10.3389/frlct.2024.1373029) describes the lung chip as a three-dimensional simulation of a human lung on a microchip that can “breathe”, built from human lung and blood-vessel cells. The same review notes that traditional cell lines and animal models do not fully replicate the complexity of human lung tissue, which is the gap the chip format is designed to address.

Scope matters here. A lung chip models a defined tissue interface under controlled mechanics; it is not a whole lung, and it does not reproduce every cell type, immune interaction or systemic effect. For the regulatory and animal-replacement context in which these devices are discussed, see the CASRAI guide on the organ-on-a-chip replacement method and the dictionary entry for new approach methodologies (NAMs).

How a lung-on-a-chip works

The alveolar-capillary interface

The founding paper is Huh and colleagues, “Reconstituting organ-level lung functions on a chip” (Science 2010;328:1662-1668, from the Ingber laboratory at the Wyss Institute; PubMed 20576885). The authors report that the device reconstitutes the alveolar-capillary interface of the human lung and reproduces organ-level responses to bacteria and inflammatory cytokines introduced into the alveolar space. The work was funded in part by NIEHS grant R01 ES016665.

Air-liquid interface culture

Most lung chips rely on air-liquid interface (ALI) culture, in which the epithelial surface is exposed to air while the underside is fed with medium. According to Park and colleagues, ALI is critical for mucociliary differentiation, pseudostratified morphology and epithelial barrier development. They also report that ALI can be established by submerged culture followed by sequential air-exposure steps, and that submerged culture is linked to hypoxia-related signalling that represses ciliated-cell differentiation.

What the review reports about culture conditions

The review collects several culture findings that a lab planning a lung chip has to weigh. Submersion is linked to hypoxia (accumulation of HIF-1α and HIF-2α) and Notch signalling that represses ciliated-cell differentiation, citing Gerovac and colleagues (2014). Modulating Wnt signalling affects ciliated-cell differentiation under ALI (Schmid and colleagues, 2017). A smaller apical medium volume gave the greatest stimulation of ciliogenesis in normal human bronchial epithelial cells on Transwell inserts. A two-week ALI culture was reported as optimal for alveolar-like properties of A549 cells (Wu and colleagues, 2018). Chip-based airflow, in a 2023 study cited by the review, produced more representative mucociliary differentiation under bidirectional flow than under constant unidirectional flow.

Mechanical forces: stretch and flow

Breathing motion is simulated by cyclic stretching of the membrane, and blood flow is replicated by flow through the vascular channel. The chip can also be built up with epithelial cells, extracellular matrix, fibroblasts, collagen and immune cells, depending on the question being asked. Mechanical forces are not decoration: they change cell behaviour, a topic covered more generally under organoid and advanced culture models.

Why strain changes the result

Huh and colleagues found that cyclic mechanical strain accentuated the toxic and inflammatory responses of the lung model to silica nanoparticles, and that strain enhanced epithelial and endothelial uptake of the nanoparticles and their transport into the underlying microvascular channel. A similar effect of breathing was seen in whole mouse lung. This is the central argument for a moving device rather than a static insert: if stretch alters particle uptake, a model without stretch can understate or misrepresent exposure effects.

Four studies, four strain regimes

Stucki and colleagues (2015) applied up to 10% linear cyclic strain to 16HBE14o- bronchial epithelial cells on a PDMS chip and found that cyclic stretch increased epithelial permeability, measured with a FITC-sodium test. Doryab and colleagues (2021) applied 10% linear strain at 0.33 Hz to A549 cells under ALI and reported enhanced uptake of 100 nm particles. Huang and colleagues (2021) used primary human alveolar cells in a GelMA hydrogel on PDMS under 8% cyclic strain and reported maintained viability and structure for 48 hours, with enhanced ZO-1 tight junctions. Tas and colleagues (2021) used mouse MLE-12 cells on a polycaprolactone nanofibrous membrane as a ventilator-induced lung injury model at about 25% pathologic strain, which induced cell death and nuclear translocation of YAP/TAZ.

The common thread is that stretch is an experimental variable with consequences for barrier function, particle uptake and cell survival, so the strain and frequency belong in the methods section of any study that uses these devices. The organ-on-a-chip guide covers how such methods fit the wider movement towards animal-free testing.

The data table below compiles four later studies summarised in the 2024 review, showing which strain was applied to which cell model and what was reported. Strain values differ by design, and the review itself includes a pathological-range example to show that excessive stretch is also modelled.

Design features of commercial lung chip systems

Park and colleagues tabulate commercial systems suited to ALI culture. Only the entries that the review lists with explicit values are shown here.

System (company, country) Membrane or barrier Pore size / thickness Stretch
AXLung-on-Chip (AlveoliX, Switzerland) PDMS 3 µm pore; 3.5 µm thick 8% linear; 12 cycles/min
S1 chip (Emulate, US) PDMS 7 µm pore; 50 µm thick 0-12% strain; 0.01-0.4 Hz
SynALI (Synvivo, US) PDMS 3 µm pore; 50 µm thick Not listed
OrganoPlate (MIMETAS, Netherlands) No artificial membrane; extracellular matrix gel separates channels Not listed Not listed

Three points follow from the table. Membrane designs differ, from porous PDMS to gel-separated channels. Not every system applies stretch. And the review notes that some commercial platforms (CN Bio and TissUse) can run lung models grown on inserts rather than on a built-in membrane.

Chip format versus insert-based format

Two configurations of lung model are in use, and the choice changes what a lab can measure and how it can dose. The following comparison is taken from an article in Drug Development and Delivery (January/February 2022) written by the chief executive of CN Bio Innovations, a company that sells insert-based systems, so it should be read as a vendor-authored description rather than a neutral benchmark.

Microfluidic chip

Cells are seeded into a pair of microfluidic channels separated by a porous membrane, as in the 2010 Huh device. Stretching the elastomeric membrane provides mechanical stimulation, which the article says enhances lung phenotype compared with unstimulated controls. The drawbacks it lists are complex set-up, low throughput, difficult cell seeding and collection, and poor compatibility with laboratory automation and aerosol dosing.

Insert-based system

Standard cell-culture inserts with a porous membrane base, such as Transwell inserts, are combined with fluid flow. Epithelial cells sit in the apical compartment at the air-liquid interface, with optional endothelial cells below. The article lists these advantages: easy access for washing and barrier checks, removability for commercial aerosol-testing equipment, no drug absorption by the insert, and ease of imaging.

PDMS and drug absorption

The same article states that valid concerns surround the extent of drug absorption into PDMS elastomeric chips. The 2024 review points to the same issue from the design side: it notes that the MIVO system from REACT4LIFE is designed without PDMS to avoid unintended molecule binding, and that BEOnChip uses lipophobic thermoplastic polymers that the review’s table says reduce unspecific medication absorption.

The practical reading for a protocol: the chip format emphasises mechanical realism (stretch), while the insert format emphasises access, imaging and aerosol dosing. Neither article claims one format is better for every question, and the 2024 review notes that some commercial platforms can run lung models grown on inserts.

Uses named in the vendor-authored article

The article names modelling diseases such as COVID-19, predicting human absorption, distribution, metabolism and excretion (ADME) for inhaled drugs, identifying toxicants, multi-organ crosstalk studies and dosing with airborne species to improve translatability. It also describes SARS-CoV-2 infection and immune-response studies enabled by ACE2 expression in the model.

Where lung chips are used in research and lab practice

The 2024 review lists these applications from the primary literature it cites:

  • Infection and antiviral testing, including an influenza airway chip.
  • Inhalation toxicology of nanoparticles such as TiO2 and ZnO.
  • Drug permeability and nanoparticle transport.
  • Safety testing of immunotherapies such as T-cell bispecific antibodies.
  • Tumour biology, including T-cell migration in a lung tumour model.
  • Imaging of cilia beat frequency and mucociliary transport.
  • Multi-organ toxicology using lung-liver co-culture.

Huh and colleagues likewise suggested that such a device may provide a low-cost alternative to animal and clinical studies for drug screening and toxicology. For a lab team, the practical question is usually which cell source to put in the chip. The review discusses several: A549 cells needed adjusted culture conditions to better approximate alveolar properties (see A549 cells), Calu-3 cells lack basal cells and kinocilia and are described as unsuitable for cilia studies, and primary alveolar type 2 cells are reported to stop replicating in vitro and begin trans-differentiating toward type 1-like cells under ALI within days.

Choosing cells for a lung chip: what the literature reports

The cell source shapes what a chip can show. The 2024 review describes these cases:

  • Calu-3: described as unsuitable for cilia studies because it lacks basal cells and kinocilia; higher TEER was reported under submerged culture.
  • 16HBE14o-: used in the Stucki 2015 chip; submerged culture gave higher TEER.
  • A549: required media changes and a two-week ALI period to better approximate alveolar characteristics.
  • hAELVi: shows heterogeneity from a single donor.
  • Primary alveolar type 2 cells: reportedly stop replicating in vitro and begin trans-differentiating toward type 1-like cells within days under ALI.
  • MLE-12: a mouse cell line used in the Tas 2021 ventilator-injury model.

These are statements about published findings, not recommendations; the right model depends on the research question, and the review does not rank them.

Common misunderstandings

One lung-on-a-chip design does not stand for all

Chip and insert formats, PDMS and non-PDMS materials, and with or without stretch are all in use. A claim about “the” lung chip should name which design it refers to, because the sources above describe different trade-offs in throughput, automation, imaging, aerosol dosing and drug absorption.

A lung chip is not a miniature lung

The device models an interface and its mechanics, not an organ. The review states that replicating the structure and function of the human lung remains a challenge.

Air-liquid interface is not always better for every readout

The review reports that 16HBE14o- and Calu-3 cells gave higher transepithelial electrical resistance (TEER) under submerged culture, which complicates barrier comparisons across ALI and submerged conditions.

Stretch is not a single setting

Published studies use different strains and frequencies (see the data table). Results from one cell model and one strain level should not be assumed to transfer to another.

The format has stated limitations

The review’s conclusion cites high cost, complexity and low experimental reproducibility. It also states that the role of shear stress in airway epithelial stability has not yet been clarified.

Sources

  • Huh D, et al. Reconstituting organ-level lung functions on a chip. Science. 2010;328:1662-1668. PubMed 20576885, pubmed.ncbi.nlm.nih.gov/20576885 (abstract read 2026-11-19).
  • Park S, Woo CG, Cho Y-J. Revolutionizing respiratory health research. Frontiers in Lab on a Chip Technologies. 2024;3. doi 10.3389/frlct.2024.1373029, frontiersin.org (read 2026-11-19).
  • Drug Development and Delivery. Organ-on-a-chip: a novel way to accurately test delivery of non-standard formulations. January/February 2022. drug-dev.com (read 2026-11-19).
  • Lung-on-a-chip: the future of respiratory disease models and pharmacological studies. PubMed 31906727, pubmed.ncbi.nlm.nih.gov/31906727 (abstract read 2026-11-19).

Data: Cyclic strain regimes in four lung-on-a-chip and lung cell studies summarised in a 2024 review

Compares the cell model, substrate, strain applied and reported finding of four studies on cyclic mechanical strain in lung cell culture, compiled from the Table of strain studies in Park, Woo and Cho (2024, Frontiers in Lab on a Chip Technologies).

Period covered: 2015/2021.

Cyclic strain regimes in four lung-on-a-chip and lung cell studies summarised in a 2024 review
StudyCell model and substrateStrain appliedFrequencyReported finding
Stucki et al., 201516HBE14o- cells on a PDMS chipUp to 10% linearNot stated in reviewCyclic stretch increased epithelial permeability
Doryab et al., 2021A549 cells under air-liquid interface10% linear0.33 HzStretch enhanced uptake of 100 nm particles
Huang et al., 2021Primary human alveolar cells in GelMA hydrogel on PDMS8% cyclicNot stated in reviewViability and structure maintained for 48 h; enhanced ZO-1 tight junctions
Tas et al., 2021MLE-12 cells on PCL nanofibrous membrane (ventilator-induced injury model)About 25% (pathologic)Not stated in reviewInduced cell death and YAP/TAZ nuclear translocation

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Lung-on-a-Chip: What It Is, How It Works and What It Models

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →