Skip to main content
v2026.11,986 entries · CC-BY 4.0

LysoTracker Probes: Staining, Specs & Protocols

LysoTracker fluorescent probes label acidic organelles in live cells. Compare spectral specs, working protocols, storage rules, and imaging controls.

Written and maintained by CASRAI Editorial Board

Published

On this page

Short answer

LysoTracker is a commercial family of cell-permeable, fluorescent acidotropic probes used to selectively label and track acidic organelles—primarily lysosomes and late endosomes—in living cells. Developed by Molecular Probes (now Thermo Fisher Scientific), these dyes accumulate through an ion-trapping mechanism and emit distinct wavelengths across the spectrum for live-cell fluorescence microscopy and organelle trafficking studies.

Definition and scope

LysoTracker probes are fluorophores linked to weakly basic amine moieties designed for live-cell imaging of acidic compartments. At neutral physiological pH (7.2 to 7.4), the weak base remains uncharged, allowing dye molecules to freely permeate cellular lipid bilayers via passive diffusion. Inside low-pH luminal environments, such as mature lysosomes (pH 4.5 to 5.5), the tertiary amines undergo protonation. Positively charged protonated molecules cannot cross back through lipid bilayers, trapping the probe inside the organelle.

The operational scope of LysoTracker reagents is restricted to research workflows in living cells and tissues. They are research-use-only (RUO) fluorophores used to track acidic organelle morphology, autophagy progression, and endocytic trafficking. Because retention requires an active transmembrane proton gradient across intact membranes, chemical fixation dissipates the gradient and disperses the dye. Consequently, LysoTracker dyes are not histological counterstains or immunofluorescence reagents for fixed diagnostic specimens.

How it works or how it is used in practice

LysoTracker accumulation depends on vacuolar-type H+-ATPase (V-ATPase) proton pumps, which acidify the lysosomal lumen. In practice, researchers prepare live-cell cultures on glass-bottom vessels and incubate them with nanomolar probe dilutions in culture medium or a physiological buffer solution. To avoid cold shock, staining is conducted at 37°C in pre-warmed media or isotonic solutions like phosphate buffer.

Authoritative manufacturer guidelines from Thermo Fisher Scientific (Manual MAN0001924 / MP 07525) and standard methodologies in Cold Spring Harbor Protocols (Chazotte, 2011) establish an effective working concentration of 50 nM to 75 nM, with loading durations from 30 minutes to 2 hours. Keeping probe concentrations in the low nanomolar regime is essential; excessive concentrations act as lysosomotropic agents that artificially elevate luminal pH, promote vacuolar swelling, and trigger cellular blebbing.

Following incubation, cultures are imaged directly or washed gently with pre-warmed medium. Stained specimens are observed on standard widefield epifluorescence microscope platforms, laser scanning confocal systems, light-sheet microscopy chambers, or setups adapted for STORM super-resolution imaging. In live-cell workflows, researchers introduce pharmacological controls to confirm probe specificity. Pre-treatment with bafilomycin A1—a specific nanomolar V-ATPase inhibitor—neutralizes luminal acidity, abolishing the pH gradient and preventing probe accumulation. Similarly, rapid loss of punctate fluorescent signal serves as an experimental readout for lysosomal membrane permeabilization (LMP).

For quantitative analysis, researchers must maintain strict rigor. As demonstrated by Estrada Toro et al. (Journal of Visualized Experiments, 2026, PMID 42545930), LysoTracker punctate signal area and integrated intensity correlate with total expanded volume of the acidic compartment and intact proton gradient, rather than representing an absolute count of physical lysosomes or a direct measure of de novo biogenesis.

LysoTracker dyes are available in six distinct spectral formulations, spanning ultraviolet excitation through the far-red optical window. All six variants, catalog numbers, and spectral parameters—as specified in Thermo Fisher Scientific Manual MAN0001924 / MP 07525 (Revision 2.0)—are outlined in the reference table below:

Probe Name Catalog Number Excitation Max (nm) Emission Max (nm) Fluorescence Profile & Channel
LysoTracker Blue DND-22 L7525 373 422 Blue fluorescence; standard DAPI / UV filter set
LysoTracker Blue-White DPX L12490 380 576 (methanol) Environment-sensitive; appears blue-white in acidic organelles
LysoTracker Green DND-26 L7526 504 511 Bright green fluorescence; standard FITC / GFP filter set
LysoTracker Yellow-HCK-123 L12491 465 535 Yellow-green fluorescence; multiplexable with UV or far-red markers
LysoTracker Red DND-99 L7528 577 590 Bright red fluorescence; TRITC / rhodamine / RFP filter set
LysoTracker Deep Red L12492 647 668 Far-red / near-infrared fluorescence; Cy5 filter set

A critical distinction exists between LysoTracker reagents and LysoSensor probes, which differ fundamentally in optical response:

Parameter LysoTracker Probes LysoSensor Probes
Primary Mechanism Acidotropic accumulation in organelle lumen Acidotropic accumulation with pH-dependent dequenching
Spectral Response to pH Fluorescence is largely pH-independent once trapped Fluorescence intensity or dual-emission ratio changes dynamically with pH
Probe pKa Values Not applicable (stable fluorophore response) Defined pKa values from 3.9 to 7.5 (e.g., DND-160, DND-189, DND-153)
Working Concentration 50 nM to 75 nM 1.0 µM or higher
Primary Laboratory Use Organelle tracking, morphology, and volume proxy Dynamic luminal pH measurement and acidification kinetics

Where it matters for labs, clinics or supply decisions

In academic, pharmaceutical, and translational laboratories, LysoTracker dyes are standard consumables for cellular phenotype screening across four core areas:

  • Autophagy Research: Monitoring autophagosome-lysosome fusion during starvation and oncology drug discovery.
  • Cellular Senescence Profiling: Tracking lysosomal compartment expansion accompanying senescent arrest in aging models.
  • Lysosomal Storage Disorders (LSDs): Evaluating endo-lysosomal enlargement in Niemann-Pick, Gaucher, and Pompe disease models.
  • Phospholipidosis Screening: Serving as a high-content biomarker during preclinical optimization to detect lysosomal perturbation.

Effective procurement and stock management are vital for maintaining experimental consistency. Laboratory managers must follow handling rules from the manufacturer:

  • Packaging and Format: Supplied as 1 mM stock solutions in anhydrous DMSO (50 µL vials; 20 vials for standard dyes, 5 vials for Deep Red). Warm to room temperature before opening.
  • Storage Temperature: Maintained at or below –20°C with desiccant and protected from light.
  • Frost-Free Freezer Prohibition: Never store in frost-free (self-defrosting) freezers; heating cycles cause freeze-thaw degradation, dye hydrolysis, and signal loss.
  • Aliquoting: Aliquot thawed stocks into single-use tubes to avoid thermal cycling. Properly stored stocks remain stable for at least six months.

Common misunderstandings

Several technical misconceptions frequently compromise live-cell lysosome imaging protocols:

  • Assumption that LysoTracker survives standard fixatives: Retention depends strictly on intact membranes and proton gradients. Aldehyde fixation causes rapid dye loss and diffuse background. While LysoTracker Red DND-99 tolerates mild aldehyde post-fixation, quantitative experiments require live-cell imaging.
  • Belief that higher concentrations enhance contrast: Increasing concentrations beyond 75 nM does not improve signal-to-noise ratio. Excessive weak-base accumulation neutralizes lysosomal acidity (the alkalinization artifact), alters trafficking, and causes cytotoxic blebbing.
  • Equating fluorescent intensity with physical lysosome counts: Integrated fluorescence reflects acidic volume, luminal pH, and dye diffusion kinetics. Signal loss indicates organelle neutralization or membrane rupture, not necessarily the numerical elimination of lysosomal vesicles.
  • Treating LysoTracker as an absolute pH meter: LysoTracker indicates acidic compartments but does not measure exact luminal pH. Quantitative pH titration requires ratiometric sensors such as LysoSensor Yellow/Blue dextran.

Frequently asked questions

Can LysoTracker be used on fixed cells?

No. LysoTracker requires living cells with intact transmembrane proton gradients to concentrate and retain the dye. Fixatives disrupt proton gradients and permeabilize membranes, resulting in rapid dye loss or diffuse background. For fixed samples, researchers should use primary antibodies against lysosomal membrane proteins (such as LAMP1 or LAMP2) rather than LysoTracker.

How does bafilomycin A1 affect LysoTracker staining?

Bafilomycin A1 is a nanomolar inhibitor of the vacuolar H+-ATPase (V-ATPase) proton pump. Treatment halts proton translocation, rapidly neutralizing the lysosomal lumen to cytosolic pH. Because LysoTracker requires an acidic lumen for amine protonation and trapping, bafilomycin A1 completely abolishes punctate staining, serving as a negative control for pH-dependent accumulation.

What is the difference between LysoTracker Green and LysoTracker Deep Red?

LysoTracker Green DND-26 excites at 504 nm and emits at 511 nm (FITC/GFP channel), but rapid cellular uptake can induce lysosomal alkalinization if incubated too long. LysoTracker Deep Red excites at 647 nm and emits at 668 nm (far-red / Cy5 channel), offering superior photostability, minimal cellular autofluorescence, and straightforward spectral multiplexing with green and red fluorescent proteins.

Why does LysoTracker signal fade or wash out after staining?

When stained cells are incubated in dye-free medium, reversible chemical equilibrium allows uncharged dye molecules to diffuse out of acidic compartments. Photobleaching during continuous illumination also extinguishes fluorophore emission. To maintain signal intensity, researchers should image cells promptly or maintain a minimal probe concentration in the imaging buffer.

Sources

  • Thermo Fisher Scientific / Molecular Probes (MAN0001924 / MP 07525, Revision 2.0). LysoTracker® and LysoSensor™ Probes: Molecular Probes Product Information. Document URL: https://documents.thermofisher.com/TFS-Assets/LSG/manuals/mp07525.pdf (Verified and read 2026-11-10).
  • Chazotte, B. (2011). “Labeling lysosomes in live cells with LysoTracker.” Cold Spring Harbor Protocols, 2011(2): pdb.prot5571. DOI: https://doi.org/10.1101/pdb.prot5571 (PMID: 21285271) (Verified and read 2026-11-10).
  • Estrada Toro, J., Tenenbaum, S. A., Larsen, M., Begley, T. J., & Melendez, J. A. (2026). “Lysosomal Profiling With LysoTracker For Quantitative Assessment of Cellular Senescence In Human Fibroblasts.” Journal of Visualized Experiments, (210): e70684. DOI: https://doi.org/10.3791/70684 (PMID: 42545930) (Verified and read 2026-11-10).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about LysoTracker Probes: Staining, Specs & Protocols

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →