Modal Analysis: Natural Frequencies, Mode Shapes and FRF Testing

Modal analysis finds a structure’s natural frequencies and mode shapes, computed by finite element or measured as FRFs. Includes node pitfalls and ISO 7626.

Written and maintained by CASRAI Editorial Board

Published

On this page

Modal analysis finds how a structure vibrates on its own: its natural frequencies (the frequencies at which it prefers to vibrate when disturbed and left alone) and the mode shape that goes with each one (the pattern of deformation at that frequency). It can be computed from a finite element model or measured on a real structure with an impact hammer or shaker and accelerometers, and the two routes are used to check each other.

Definition and scope

In the formulation used by the Abaqus documentation, modal analysis looks at free vibration: the structure has no external load and, in the basic form, no damping. The governing problem is K φ = λ M φ, where K is the stiffness matrix, M the mass matrix, φ a mode shape and λ = ω² the eigenvalue. The square root of each eigenvalue is the natural frequency of that mode, and the eigenvector is the deformed shape of the structure as it vibrates in that mode. A model with n degrees of freedom has n eigenvalues, so a finite element model always returns a finite list of modes even though a real continuous structure has infinitely many.

The simplest case is a single mass on a spring. Autodesk’s Fusion Simulate documentation gives its natural frequency as fn = √(k/m) / (2π) in hertz, where k is stiffness and m is mass, with ω = √(k/m) in radians per second. Stiffer structures raise the frequency, heavier ones lower it. Real structures behave like many such oscillators coupled together, and the amplitude pattern across the degrees of freedom at each frequency is the mode shape.

Modal analysis is therefore not a stress or strength calculation. It describes the dynamic character of a structure. Its main design use, as the Abaqus guide puts it, is to check that loads do not occur near a natural frequency, because resonance can greatly increase displacement amplitudes.

How modal analysis is done in practice

Computational route: finite element eigenvalue analysis

In a finite element package you build the model, apply the supports, and request the modes. In Abaqus/Standard you specify either the number of modes required or the maximum frequency of interest. The solver returns frequencies and mode shapes, but they describe the undamped system. The Fusion Simulate documentation states that damping is not considered in its natural frequency calculation. It adds that damping in common materials is small, so the undamped result is usually close to the real one, and that damping lowers the frequency compared with the undamped value.

Experimental route: measure the frequency response

Experimental modal analysis excites the structure and measures the response. The quantity measured is the frequency response function (FRF), the ratio of response to force as a function of frequency. When the response is acceleration, the FRF is called accelerance, A(ω) = a(ω)/F(ω), in m/s² per newton. Mobility (velocity over force) and dynamic compliance (displacement over force) are the related forms, and ISO 7626 treats all three.

A published worked example from Dewesoft tests an aluminium beam on simple supports. The set-up it describes is a good template for what an impact test involves:

  • An impact hammer with a load cell (10 kg, 2 mV/V) delivers the force; seven IEPE accelerometers (100 mV/g) are attached magnetically at points 1 to 7, spaced 1 m apart.
  • The hammer strikes point 2 with force kept under about 1 g of response (around 10 N) to avoid noise and double impacts.
  • The acquisition system samples at 400 Hz, with exponential windows on the response and a 5 N trigger. A frequency resolution of 0.01 Hz needs a 100 s window, and four windows were averaged.
  • One fixed impact point with seven response points gives seven FRFs. The one measured at the impact point itself (FRF 22) is the driving-point accelerance.

The frequency resolution follows from the record length: resolution in hertz is the reciprocal of the window length in seconds, which is why 0.01 Hz needs 100 s. The standard that governs this type of measurement is covered in the ISO 7626 section below.

Reading an FRF: peaks, phase, coherence and nodes

The Dewesoft example identifies natural frequencies as peaks in the FRF magnitude that coincide with a phase shift near 180°. A magnitude peak alone is not enough; the phase change is the second confirmation that the peak is a resonance. For the simply supported beam it reports three modes in the 0 to 30 Hz band: 2.96 Hz, 11.69 Hz and 25.86 Hz. The first is a single half-sine, the second has a central node at point 4, and the third has nodes at points 3 and 5.

The same data set shows the most useful practical lesson in experimental modal testing: a sensor placed on a node cannot see that mode. FRF 42, with the response measured at point 4, shows only two peaks because point 4 is the node of the second mode. FRFs 32 and 52 lack the 25.86 Hz peak because points 3 and 5 are nodes of the third mode. The supports at points 1 and 7 give noisy, near-zero FRFs because they barely move. A mode is missing from one FRF not because the structure lacks it, but because of where that sensor sits, which is why several response points are measured and compared. The data table below sets out the three modes and the FRFs in which each one disappears.

The same article uses the coherence function as a quality check, stating that it should be close to 1 for a linear FRF estimate; coherence runs from 0 to 1 and shows how much of the response is explained by the measured input. It also notes small lobes in the FRF magnitude that it attributes to impacts landing while the beam was not completely at rest, and concludes that tighter control of the impacts is needed. Damping ratios were not addressed in that example, so the example gives frequencies and shapes only.

Finite element versus experimental modal analysis

The two routes answer the same question from opposite directions. The table compares them using only what the sources above state.

Aspect Finite element (computed) Experimental (measured)
Starting point Stiffness and mass matrices of a model Force and response signals from a real structure
Core relation K φ = λ M φ, with ω = √λ FRF such as accelerance A(ω) = a(ω)/F(ω)
How a natural frequency is identified Square root of an eigenvalue Magnitude peak with a phase shift near 180°
How a mode shape appears Eigenvector: deformed shape in that mode Pattern of FRFs across response points, including nodes
Number of modes Equal to the degrees of freedom of the model Whatever falls in the measured band (three in the 0 to 30 Hz beam example)
Damping Not included in the basic undamped problem Present in the measured response (not evaluated in the beam example)
Quality indicator Modes requested by count or maximum frequency Coherence close to 1; controlled impact level and trigger

A misleading result in either route usually has a cause that the table points to: a computed list is only as complete as the model is fine, and a measured list is only as complete as the sensor and excitation positions allow.

The ISO 7626 measurement standards

Experimental FRF measurements are standardised in the ISO 7626 series, “Mechanical vibration and shock: experimental determination of mechanical mobility”. Two parts are directly relevant to modal testing:

  • ISO 7626-2:2015 (published 31 May 2015, status current in the BSI catalogue) gives procedures for measuring linear mechanical mobility and other frequency response functions of structures such as buildings, machines and vehicles, using single-point translational excitation with an attached vibration exciter. It covers mobility, accelerance, dynamic compliance and their reciprocals (for example free effective mass), as driving-point or transfer measurements, with motion at any number of points.
  • ISO 7626-5:2019 (second edition, December 2019, replacing the 1994 edition) covers measurement with impact excitation, using an exciter that is not attached to the structure. It applies to mobility, accelerance and dynamic compliance as driving-point or transfer measurements. The signal analysis it covers is based on the discrete Fourier transform, usually computed with an FFT. The catalogue description notes that quick impact tests can help plan more detailed random or sinusoidal tests.

The hammer test in the Dewesoft example is an impact-excitation measurement of the kind Part 5 addresses, while a shaker bolted to the structure falls under Part 2. Part 5 excludes step relaxation and transient random methods because they need an attached exciter. Which edition and which parts apply to a given test programme should be confirmed against the standard itself, since this page summarises catalogue descriptions rather than the full text.

Where modal analysis matters in laboratory and research testing

For a laboratory that tests structures, equipment mounts or machine components, the practical uses that the sources support are narrow and concrete:

  • Avoiding resonance in design. Compare the structure’s natural frequencies with the frequencies of the loads it will see; the Abaqus guide frames this as the central design reason to do the analysis.
  • Checking a model against reality. ISO 7626-5 describes impact-based mobility measurement as useful for validating finite element models. Matching measured and computed frequencies and mode shapes is the standard way to build confidence in a model.
  • Planning a test. A quick impact test can establish where the resonances lie before a longer random or sinusoidal programme is designed.
  • Documenting measurement quality. Instrument calibration status and the sensitivity values behind the force and acceleration channels matter to the credibility of an FRF. Related background on how calibration intervals and certificates are handled in accredited laboratories is in calibration interval and the ISO 17025 calibration certificate guide.

Frequency-domain analysis of sampled signals underlies every FRF; for a code-level view of how frequency bins are generated from a sampled record, see fftfreq in MATLAB. Where the question moves from vibration behaviour to failure-time statistics, the separate guide to Weibull analysis covers reliability modelling.

Common misunderstandings

Natural frequencies from a finite element model include damping

The basic eigenvalue problem is undamped. Damping is small in common materials, so the undamped frequency is usually close to the damped one, but damping does lower the frequency compared with the undamped value.

A model with more degrees of freedom has more physical modes

A real continuous structure has infinitely many modes; the finite element model has exactly as many as it has degrees of freedom. More degrees of freedom give a longer list and a better description of the higher modes, but they do not change the underlying structure.

A flat FRF means no resonance

A sensor on a node does not respond in that mode. In the beam example the response at point 4 shows two peaks instead of three. Measuring at several points avoids reading a missing peak as a missing mode.

Any peak in an FRF is a natural frequency

The identification described in the worked example needs a magnitude peak together with a phase shift near 180°, and a coherence close to 1 for the estimate to be linear. Noise and impacts on a moving structure can create small features that are not modes.

It gives frequencies and shapes of free vibration. It does not by itself give stresses or fatigue life. Those need a response analysis with real loads.

FAQ

What is modal analysis in simple terms?

It is the study of a structure’s natural ways of vibrating: each mode has a natural frequency and a characteristic deformed shape. It can be computed from a model or measured with a hammer or shaker and sensors.

What are natural frequency and mode shape?

The natural frequency is the square root of an eigenvalue of K φ = λ M φ (or, for one mass and spring, √(k/m) / 2π hertz). The mode shape is the eigenvector, the deformed shape in that mode.

How many modes does a structure have?

A real continuous structure has infinitely many. A finite element model has as many as its degrees of freedom.

How do you find natural frequencies from a measurement?

Measure the FRF and look for magnitude peaks that coincide with a phase shift near 180°, checking that coherence is close to 1.

Why does a mode disappear from one of my measurements?

The sensor is probably at a node of that mode. In the worked beam example, point 4 is the node of the 11.69 Hz mode.

Which standards cover mobility and FRF measurement?

The ISO 7626 series; Part 2 covers attached-exciter measurements and Part 5 covers impact excitation.

Sources

Data: Worked modal results for a simply supported aluminium beam (0-30 Hz)

Natural frequencies, mode shape features and FRFs that lose the peak for each of the first three modes in a published impact-hammer test with seven accelerometers at 1 m spacing; compiled from the published worked example.

Period covered: 2026.

Worked modal results for a simply supported aluminium beam (0-30 Hz)
ModeNatural frequency (Hz)Mode shape featureNode point(s)FRFs without this peak
Mode 12.96Single half-sineNoneNone reported
Mode 211.69Node at beam centrePoint 4FRF 42
Mode 325.86Nodes either side of centrePoints 3 and 5FRF 32, FRF 52

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Modal Analysis: Natural Frequencies, Mode Shapes and FRF Testing

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →