Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
MolProbity is an all-atom structure-validation service for biological macromolecules. You give it a model of a protein, a nucleic acid or a complex, and it reports steric clashes, backbone and side-chain conformation problems and related geometry checks. The original server run by the Richardson Laboratory at Duke University has reached end of life (notice read 2026-11-08); its replacement, MolProbity Next, is hosted by the Berkeley Phenix Project at molprobity.lbl.gov and is labelled alpha.
This guide is for structural biologists and core-facility staff who need to check a model before deposition or publication. After reading it you should know where the current service lives, what the upload form accepts, and which analyses the published method covers.
What MolProbity is used for in research
MolProbity’s own description of the current service is “all-atom structure validation for biological macromolecules”: an uploaded structure gets comprehensive all-atom contact analysis and geometry validation for proteins, nucleic acids and their complexes. It is typically run on a model from X-ray crystallography or cryo-EM refinement (for example after processing in cryoSPARC) before the coordinates are deposited, and it can also be applied to models fetched from the PDB.
The method is described in Williams et al., “MolProbity: More and better reference data for improved all-atom structure validation”, Protein Science 27(1):293-315 (2018), doi 10.1002/pro.3330. According to its abstract, the paper reports:
- the former Java utilities rewritten in Python on the CCTBX toolkit within Phenix, with open-source code and reference datasets on GitHub;
- correction of flipped Asn, Gln and His side chains;
- two sets of hydrogen distances and van der Waals radii: electron-cloud-centre positions for X-ray models and nuclear positions;
- updated Ramachandran and rotamer criteria derived from about one million quality-filtered residues;
- CaBLAM, an analysis of C-alpha to CO virtual angles that assesses backbone and secondary structure in cryo-EM or low-resolution X-ray models;
- flagging of very rare cis-non-proline and twisted peptides;
- messages about irregularities in the input file format;
- an observed improvement in newly deposited structures as measured by MolProbity’s all-atom clashscore.
How to install or access it
There is nothing to install for the web service. Use the official addresses below and update any bookmarks, scripts or documentation that point at the old server, as the Duke notice instructs.
| Route | Status as read on 2026-11-08 | Source |
|---|---|---|
| Duke MolProbity (molprobity.biochem.duke.edu) | End of life; users are asked to migrate to MolProbity Next | Notice on the Duke site |
| MolProbity Next (molprobity.lbl.gov) | Current service, hosted by the Berkeley Phenix Project; banner reads “Alpha – under active development. Validation results and page layout may change” | molprobity.lbl.gov |
| Phenix | The 2018 paper reports the MolProbity utilities were rewritten in Python/CCTBX within Phenix | Williams et al. 2018 |
Because MolProbity Next is in alpha, results and page layout can change between visits. Record the date you ran a validation alongside the numbers you report.
Step-by-step: validate a model on MolProbity Next
- Open
https://molprobity.lbl.gov/. - Choose the File Upload tab to upload your own model, or the Fetch from PDB tab to retrieve a deposited entry. Accepted upload formats are PDB (
.pdb,.ent) and mmCIF (.cif,.mmcif); gzip-compressed files (.gz) are accepted. - Set the Asn/Gln/His flips option. The choices are “Allow flips” (recommended, the default) and “Keep as deposited”. When hydrogens are added, these side chains may be turned 180 degrees if that fits hydrogen bonds and contacts better, and the clash and water results use that model.
- If the model contains non-standard residues or ligands, open the advanced options and add the ligand restraint CIF file(s). They are optional in general but required for clashscore analysis of non-standard residues; the form names eLBOW, ACEDRG and Grade as sources of these files.
- Submit the job and open the results when it finishes.
Output and how to read it
The results cover the analyses listed in the 2018 paper: all-atom contacts and clashscore, Ramachandran and rotamer assessments, CaBLAM backbone analysis, and flags for cis-non-proline and twisted peptides. Take cutoffs and percentile definitions from the Validation Guide linked in the MolProbity Next navigation rather than from third-party summaries, because the alpha service may change how results are presented. Clashscore is also discussed in the X-ray crystallography guide in the context of deposition.
Two choices change what you see. The flip option decides whether the clash results come from a model with Asn/Gln/His side chains re-oriented. And the paper’s two radius sets (electron-cloud-centre for X-ray, nuclear positions) mean the experimental method matters when interpreting contacts.
Troubleshooting
- Non-standard residues are not analysed for clashes. The form states ligand restraint CIFs are required for clashscore analysis of non-standard residues. Generate them with eLBOW, ACEDRG or Grade and upload them under advanced options.
- Messages about the input file. The 2018 paper reports that MolProbity issues messages about format irregularities. Correct the model file (or re-export it as PDB or mmCIF) and resubmit.
- Old links or scripts fail. They probably point at the end-of-life Duke server; switch to molprobity.lbl.gov.
- Results differ from an earlier run. The service is labelled alpha and states that results may change; also check whether the flip setting differs.
Related routes
The 2018 paper reports that the MolProbity tools were integrated into Phenix, so Phenix is the nearest related route to the web service. For validation steps that happen at deposition, see the X-ray crystallography guide.
FAQ
Is the Duke MolProbity server still available?
No. Its home page carries an End of Life notice (read 2026-11-08) asking users to migrate to MolProbity Next at molprobity.lbl.gov.
Who runs MolProbity Next?
The Berkeley Phenix Project hosts it, per the Duke notice. The original server was operated by the Richardson Laboratory at Duke University.
What file formats can I upload?
PDB (.pdb, .ent) and mmCIF (.cif, .mmcif), optionally gzip-compressed.
Should I allow Asn/Gln/His flips?
The form recommends “Allow flips” and uses it as the default. Choose “Keep as deposited” only if you need the side-chain orientations unchanged.
Does MolProbity work for cryo-EM models?
The 2018 paper describes CaBLAM specifically for backbone and secondary-structure assessment in cryo-EM or low-resolution X-ray models.
Sources
- MolProbity Next, molprobity.lbl.gov, read 2026-11-08.
- Duke MolProbity end-of-life notice, molprobity.biochem.duke.edu, read 2026-11-08.
- Williams CJ et al. MolProbity: More and better reference data for improved all-atom structure validation. Protein Sci. 2018;27(1):293-315. PubMed 29067766, doi 10.1002/pro.3330, read 2026-11-08.







