Written and maintained by CASRAI Editorial Board
Published
On this page
NOISE-CON is the premier annual technical conference organized by the Institute of Noise Control Engineering of the USA (INCE-USA), dedicated to advancing the theory, experimental methodologies, instrumentation, and practical applications of noise and vibration control across mechanical, aerospace, environmental, and industrial domains. Established in 1973 following the passage of the federal Noise Control Act of 1972, the conference gathers acoustical engineers, laboratory researchers, regulatory compliance specialists, and industrial equipment designers to present peer-reviewed research, examine emerging noise mitigation standards, evaluate commercial instrumentation, and administer professional credentials such as the INCE Board Certification.
Definition and scope of NOISE-CON
The Institute of Noise Control Engineering of the USA (INCE-USA) was incorporated in 1971 as a non-profit professional organization to address pervasive noise challenges in transportation, manufacturing, and community environments. While traditional acoustical societies often encompass theoretical wave physics, musical acoustics, and physiological hearing mechanisms, NOISE-CON was established specifically as an engineering conference focused on noise abatement at the source, along transmission paths, and at the receiver. The inaugural NOISE-CON was held on October 15–17, 1973, in Washington, D.C., establishing a national forum that bridges laboratory research and industrial noise abatement practices.
Operating as a national member society under the International Institute of Noise Control Engineering (I-INCE), INCE-USA structures NOISE-CON around technical tracks managed by its Technical Activities Committees (TACs). These focus areas span multiple specialized engineering disciplines:
- Aeroacoustics and Aerospace Noise: Aircraft engine acoustic liners, jet plume noise, rotorcraft broadband noise, and emerging urban air mobility (UAM) acoustic signatures.
- Acoustic Materials and Metamaterials: Microperforated panel absorbers, porous acoustic liners, sonic crystals, and acoustic metamaterial barriers characterized through standardized impedance tube testing.
- Structural Acoustics and Vibration: Vibro-acoustic energy transfer, structural damping treatments, modal analysis, and statistical energy analysis (SEA) for high-frequency structural excitation.
- Transportation Noise: Automotive powertrain noise, vibration, and harshness (NVH), tire-pavement interaction noise, high-speed rail dynamic vibration, and transit vehicle exterior sound emissions.
- Industrial and Machinery Noise: Heavy manufacturing plant silencing, hydraulic circuit pulsations, fan and blower noise, compressor mufflers, and workplace noise containment enclosures.
- Building and Architectural Acoustics: Sound transmission loss across composite wall partitions, HVAC ductwork attenuators, impact isolation in multi-family dwellings, and background noise criteria.
- Environmental and Community Noise: Industrial perimeter sound propagation modeling, wind turbine infrasound evaluation, municipal noise ordinance drafting, and environmental impact assessments.
- Active Noise and Vibration Control (ANVC): Adaptive filtering algorithms, secondary source acoustic cancellation, active engine mount systems, and digital signal processing architectures.
By providing a forum where academic researchers, industrial acoustic engineers, and regulatory officials convene, NOISE-CON transforms laboratory measurement methods into codifiable engineering standards used worldwide.
How NOISE-CON operates in engineering practice
NOISE-CON operates through a rigorous technical program combining peer-reviewed manuscript publication, specialized technical sessions, educational short courses, commercial technology exhibitions, and professional board examinations. Understanding how the conference functions enables authors, researchers, and facility managers to extract actionable data for their own testing laboratories and engineering workflows.
Paper submission and peer-review workflow
The technical program follows a structured submission schedule managed via digital conference management systems. Authors must submit initial abstracts outlining their research objectives, measurement methodologies, and key acoustic findings. Abstract submissions are evaluated by relevant Technical Activities Committees for scientific relevance, technical rigor, and adherence to conference scope.
Upon abstract acceptance, authors are required to submit full technical manuscripts formatted according to official INCE-USA Microsoft Word or LaTeX templates. The review process enforces strict publication policies:
- Scientific and Technical Rigor: Papers must detail experimental setups, instrumentation calibration, governing equations, boundary conditions, and uncertainty estimations.
- Prohibition of Commercial Promotion: INCE-USA strictly prohibits blatant marketing language, unsubstantiated commercial claims, or proprietary trade designations without technical disclosure. Papers describing commercial software or instrumentation must disclose underlying algorithms or empirical validation methodologies.
- File Constraint Limits: Final camera-ready PDF manuscripts are subject to a strict 5 megabyte (5 MB) file size limit to facilitate digital indexing and seamless distribution across the INCE Digital Library.
- Presentation Obligation: At least one author must register for the conference and deliver an in-person technical podium presentation or interactive poster session. Unpresented papers are withdrawn from the published proceedings.
Proceedings archiving and bibliographic indexing
All accepted and presented papers are assigned persistent Digital Object Identifiers (DOIs) and published in the conference proceedings volume, hosted on digital platforms including IngentaConnect and the dedicated INCE Digital Library. These proceedings represent one of the most comprehensive historical repositories of applied noise control engineering in existence, spanning over five decades from 1973 to the present.
NOISE-CON proceedings are systematically cataloged by major engineering indexers, including Elsevier Scopus, Engineering Village (Compendex), and Google Scholar. Full-text access is granted to INCE-USA members as a core professional benefit, while individual papers and complete volumes remain accessible to external research institutions, university libraries, and industrial engineering libraries through institutional subscriptions or pay-per-view access.
Professional development and board certification
A distinguishing feature of NOISE-CON is its integration with professional credentialing. INCE-USA administers the INCE Board Certification program, recognizing engineers who have demonstrated superior professional competence in noise control engineering. The credential (INCE Bd. Cert.) requires documented professional engineering experience, peer references, and successful completion of comprehensive written examinations covering acoustic fundamentals and advanced practical applications. NOISE-CON regularly hosts exam review courses, specialized tutorials, and proctored examination sessions for candidates seeking board certification.
Types and related conference frameworks
To understand where NOISE-CON fits within the global acoustical and mechanical engineering landscape, researchers must distinguish between complementary technical conferences. The matrix below outlines how NOISE-CON compares to the International Congress on Noise Control Engineering (INTER-NOISE) and the meetings of the Acoustical Society of America (ASA).
| Conference Series | Organizing Body | Geographic Scope | Event Cadence | Primary Technical Focus | Proceedings Indexing |
|---|---|---|---|---|---|
| NOISE-CON | Institute of Noise Control Engineering of the USA (INCE-USA) | North America (United States and Canada) | Annual (except during U.S.-hosted INTER-NOISE years) | Applied noise and vibration control, machinery silencing, industrial compliance, transportation acoustics | Compendex, Scopus, IngentaConnect, INCE Digital Library |
| INTER-NOISE | International Institute of Noise Control Engineering (I-INCE) | International (rotates globally between Americas, Europe, and Asia-Pacific) | Annual world congress | Global noise control engineering, international acoustic standards, environmental policy, cross-border research | Compendex, Scopus, I-INCE Library, IngentaConnect |
| ASA Meetings | Acoustical Society of America (ASA) | Primarily North America with international attendance | Semiannual (Spring and Fall meetings) | Broad physical acoustics, animal bioacoustics, speech communication, musical acoustics, biomedical ultrasound | Journal of the Acoustical Society of America (JASA), ASA Digital Library |
The operational relationship between NOISE-CON and INTER-NOISE is coordinated through I-INCE. When INTER-NOISE is hosted within the United States (such as INTER-NOISE 2012 in New York City or INTER-NOISE 2015 in San Francisco), INCE-USA serves as the primary local organizing host, and NOISE-CON is integrated directly into the international congress for that calendar year.
In addition, NOISE-CON frequently establishes co-located partnerships with allied engineering societies. A notable example is NOISE-CON 2023 in Grand Rapids, Michigan, which was co-located with SAE International’s Noise and Vibration Conference. This collaborative structure enabled researchers to attend joint technical tracks addressing automotive powertrain NVH, electric vehicle interior acoustic design, and lightweight acoustic absorption treatments.
Where NOISE-CON matters for laboratories and compliance
While NOISE-CON is an academic and professional conference, the methodologies presented within its technical sessions directly impact laboratory operations, physical testing protocols, and industrial regulatory compliance. Testing facilities, analytical research laboratories, and manufacturing plants implement NOISE-CON proceedings to solve complex acoustic challenges across four key areas.
Laboratory facility qualification and low-noise environments
Precision analytical laboratories require strict environmental acoustic controls to ensure valid scientific outcomes. High background noise and low-frequency structural vibrations can distort sensitive instrumentation, including analytical microbalances, confocal microscopes, electron microscopes, and nuclear magnetic resonance (NMR) spectrometers. Facility engineers utilize Room Criteria (RC) and Noise Criteria (NC) curves defined in standards such as ANSI/ASA S12.2 to specify maximum permissible ambient noise levels from HVAC chillers, fan coil units, and fume hood exhaust systems.
NOISE-CON technical sessions regularly debut advanced active noise cancellation algorithms and tuned silencer configurations designed specifically for research facility ventilation. Proper baseline noise characterization ensures that facilities satisfy operational standards without introducing measurement artifacts. When evaluating laboratory equipment installations, researchers must ensure rigorous equipment qualification vs validation vs calibration frameworks to verify that ambient acoustic pressure does not exceed instrument manufacturer operational thresholds.
Standardized materials characterization and testing protocols
Acoustic testing laboratories rely on standardized measurement methods that are continually refined in papers presented at NOISE-CON. Two dominant test methodologies include:
- Impedance Tube Testing (ASTM E1050 / ISO 10534-2): The two-microphone transfer function method determines the normal incidence sound absorption coefficient and acoustic surface impedance of porous materials, foams, and microperforated panels. NOISE-CON research papers regularly address sample mounting edge effects, tube damping corrections, and high-temperature impedance modeling.
- Sound Transmission Loss Measurements (ASTM E90): Testing partition walls, doors, and enclosure panels in reverberant test suites to establish Sound Transmission Class (STC) ratings. Facility managers consult NOISE-CON studies to resolve flanking transmission paths and acoustic flanking leaks around laboratory doors and service penetrations.
Maintaining measurement precision across these acoustic test fixtures requires traceable microphone calibration and sensor verification, highlighting the operational importance of onsite vs sendout vs inhouse calibration strategies for precision condenser microphones and sound intensity probes.
Workplace occupational safety and hearing conservation
Industrial machinery, high-throughput centrifuges, sonicators, and pilot-scale processing equipment generate significant acoustic energy that can jeopardize worker health. Noise control engineering principles presented at NOISE-CON provide the technical basis for satisfying federal workplace safety regulations.
The Occupational Safety and Health Administration (OSHA) enforces 29 CFR 1910.95, establishing a Permissible Exposure Limit (PEL) of 90 dBA measured as an 8-hour time-weighted average (TWA) with a 5 dB exchange rate, along with an Action Level of 85 dBA triggering mandatory hearing conservation programs. Conversely, the National Institute for Occupational Safety and Health (NIOSH) recommends a more protective Recommended Exposure Limit (REL) of 85 dBA with a 3 dB exchange rate in Publication No. 98-126. Regulatory frameworks require that employers implement feasible engineering controls—such as acoustic machine enclosures, tuned silencers, and vibration isolation pads—before relying on hearing protection personal protective equipment. Incorporating sound abatement into broader facility management aligns directly with standard protocols for laboratory safety equipment.
Environmental and aerospace noise regulation
For aerospace testing laboratories and flight test facilities, NOISE-CON serves as the premier forum for tracking compliance with Federal Aviation Administration (FAA) noise certification standards under 14 CFR Part 36. These regulations mandate stringent cumulative noise level limits, evaluated in effective perceived noise decibels (EPNdB) across lateral, flyover, and approach measurement points for Stage 3, Stage 4, and Stage 5 aircraft categories. Simultaneously, environmental noise engineers utilize predictive algorithms discussed at NOISE-CON to model roadway noise barriers and industrial plant perimeters, paralleling the compliance methodologies applied in broader federal emission standards.
Step-by-step author and attendee workflow
Participating effectively in NOISE-CON—whether as a contributing research author, a technical presenter, or an attending laboratory specialist—requires following a systematic workflow across the conference lifecycle.
- Topic Identification and Track Selection: Identify ongoing research in acoustics, vibration control, or noise measurement that aligns with one of the active Technical Activities Committees. Ensure that research findings provide genuine empirical data, computational modeling with experimental validation, or novel industrial case studies.
- Abstract Preparation and Online Submission: Draft an abstract (typically 200–500 words) summarizing the background, experimental or analytical methodology, key acoustic metrics, and primary engineering conclusions. Submit the abstract through the conference portal prior to the published deadline (typically late autumn or early winter preceding the summer event).
- Manuscript Authoring and Template Adherence: Upon receiving formal notification of abstract acceptance, compose the complete technical paper (typically 6–10 pages). Use the official INCE-USA template (available in LaTeX and Microsoft Word formats), ensuring full disclosure of equations, sensor models, calibration data, and references. Verify that all figures and text fit within the mandatory 5 MB PDF file limit.
- Peer-Review Revision: Review committee comments returned by designated TAC peer reviewers. Address reviewer inquiries regarding measurement uncertainty, background noise corrections, or mathematical formulations, and submit the final camera-ready manuscript.
- Registration and Presentation Delivery: Complete author registration and prepare the technical presentation slides. Present the paper during the assigned podium session (typically 20 minutes including discussion) or during the dedicated poster exhibition.
- Post-Conference Archiving and Implementation: Following the conference, verify that the paper is indexed in the INCE Digital Library and assign the permanent DOI to institutional repositories. Review companion papers presented in the same track to extract relevant measurement protocols, materials data, or software scripts for laboratory implementation.
Common misunderstandings and technical mistakes
Practitioners entering the noise control field and first-time conference attendees frequently encounter misconceptions regarding NOISE-CON, its scope, and the acoustic principles discussed in its sessions.
- Conflating Sound Pressure Level and Sound Power Level: A frequent technical error in industrial submissions is treating sound pressure level (Lp) as an intrinsic source property. Sound pressure depends heavily on measurement distance, surface reflections, room absorption, and background noise. In contrast, sound power level (Lw) represents the total acoustic power radiated by a sound source, independent of the surrounding acoustic environment. NOISE-CON standards focus heavily on standardized sound power determination (such as ISO 3741 reverberation room and ISO 9614 sound intensity methods) to yield reproducible equipment ratings.
- Assuming NOISE-CON is a Purely Theoretical Physics Conference: Researchers outside the field often confuse NOISE-CON with pure physics symposia. While theoretical modeling is respected, NOISE-CON prioritizes applied engineering solutions that can be fabricated, tested, measured, and deployed to mitigate noise in real-world machinery, buildings, and transportation systems.
- Treating Conference Proceedings as Unreviewed Manuscripts: Because NOISE-CON publishes conference proceedings rather than a monthly periodical journal, some institutions mistakenly assume papers are unreviewed extended abstracts. In reality, INCE-USA subjects full conference manuscripts to technical peer review through its TAC review panels, ensuring that published papers meet stringent quality, reproducibility, and originality thresholds.
- Overlooking File Compression and Portal Limits: Authors frequently prepare manuscripts containing high-resolution 600 DPI bitmap graphics and uncompressed acoustic color maps, resulting in files exceeding 20 MB. When attempting final submission, the portal rejects files exceeding the 5 MB limit. Authors should optimize vector diagrams and downsample raster acoustic contour maps to 300 DPI before compiling final PDFs.
- Relying Solely on OSHA PEL for Workplace Hearing Protection: Facility managers often assume that maintaining ambient noise below the OSHA 90 dBA PEL eliminates hearing hazards. However, extensive epidemiological studies by NIOSH demonstrate that significant noise-induced hearing loss occurs at exposures between 85 dBA and 90 dBA. Leading noise control engineers presenting at NOISE-CON advocate designing engineering controls to satisfy the NIOSH 85 dBA REL with a 3 dB exchange rate rather than relying on minimum OSHA legal compliance.
The data table below summarizes recent and scheduled NOISE-CON conference editions from 2019 to 2026, documenting host locations, co-organizing bodies, featured technical tracks, proceedings archive volumes, and governing acoustical testing standards.
Frequently asked questions
What does NOISE-CON stand for?
NOISE-CON stands for the National Conference on Noise Control Engineering. It is the premier annual technical conference organized by the Institute of Noise Control Engineering of the USA (INCE-USA), established in 1973 to advance research and practical applications in noise and vibration control.
Who organizes the NOISE-CON conference?
NOISE-CON is organized by the Institute of Noise Control Engineering of the USA (INCE-USA), a non-profit professional society founded in 1971. INCE-USA is the United States member society of the International Institute of Noise Control Engineering (I-INCE) and also administers the INCE Board Certification program for professional engineers.
How does NOISE-CON differ from INTER-NOISE?
NOISE-CON focuses primarily on North American noise control engineering and is held annually across various United States host cities. INTER-NOISE is the international world congress sponsored by I-INCE that rotates globally across the Americas, Europe, and Asia-Pacific. When INTER-NOISE is hosted within the United States, INCE-USA acts as local host, and NOISE-CON is held jointly with INTER-NOISE.
Are NOISE-CON conference papers peer-reviewed?
Yes. Full technical papers submitted to NOISE-CON undergo technical peer review managed by INCE-USA Technical Activities Committees. Reviewers evaluate manuscripts for scientific validity, experimental rigor, reproducibility, and compliance with anti-commercialization guidelines before acceptance and presentation.
Where are NOISE-CON proceedings published and indexed?
NOISE-CON proceedings are published digitally in the INCE Digital Library and hosted on IngentaConnect. They receive permanent Digital Object Identifiers (DOIs) and are systematically indexed by major scientific and engineering bibliographic databases, including Elsevier Scopus, Engineering Village (Compendex), and Google Scholar.
Can non-members attend or submit papers to NOISE-CON?
Yes. NOISE-CON is open to all researchers, engineers, students, and practitioners worldwide. While INCE-USA members receive discounted registration fees and complimentary digital library access, non-members are welcome to submit abstracts, present technical papers, and attend all technical sessions, exhibits, and workshops.
Sources
- Institute of Noise Control Engineering of the USA (INCE-USA), “Conferences and Events,” https://www.inceusa.org/conferences/, accessed 2026-11-14.
- IngentaConnect, “Institute of Noise Control Engineering Conference Proceedings,” https://www.ingentaconnect.com/content/ince/confer, accessed 2026-11-14.
- International Institute of Noise Control Engineering (I-INCE), “About I-INCE and Member Societies,” https://www.i-ince.org, accessed 2026-11-14.
- Occupational Safety and Health Administration (OSHA), “Occupational Noise Exposure Standard,” 29 CFR 1910.95, https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95, accessed 2026-11-14.
- National Institute for Occupational Safety and Health (NIOSH), “Criteria for a Recommended Standard: Occupational Noise Exposure,” DHHS (NIOSH) Publication No. 98-126, https://www.cdc.gov/niosh/docs/98-126/, accessed 2026-11-14.
- Federal Aviation Administration (FAA), “Noise Standards: Aircraft Type and Airworthiness Certification,” 14 CFR Part 36, https://www.ecfr.gov/current/title-14/chapter-I/subchapter-C/part-36, accessed 2026-11-14.
- Acoustical Society of America / American National Standards Institute, “Criteria for Evaluating Room Noise,” ANSI/ASA S12.2, https://asastandards.org, accessed 2026-11-14.
- ASTM International, “Standard Test Method for Impedance and Absorption of Acoustical Materials Using a Tube, Two Microphones and a Digital Frequency Analysis System,” ASTM E1050, https://www.astm.org, accessed 2026-11-14.
Data: INCE-USA NOISE-CON Conference Series and Technical Focus Matrix (2019-2026)
An original compilation of recent and scheduled NOISE-CON conferences organized by INCE-USA, documenting host locations, co-organizing bodies, featured technical tracks, proceedings archive volumes, and associated acoustical testing standards. Compiled from official INCE-USA announcements, IngentaConnect conference archives, and federal regulatory standards.
Period covered: 2019/2026. Coverage: United States.
| Conference Edition | Host Location | Co-Organizing Body | Primary Technical Focus | Proceedings Archive Volume | Governing Acoustic Standard |
|---|---|---|---|---|---|
| NOISE-CON 2019 | San Diego, California | INCE-USA | Sound & Vibration Solutions for Transportation and Built Environments | Vol. 259 (IngentaConnect) | ANSI/ASA S12.2 Room Noise Criteria |
| NOISE-CON 2021 | Online (Virtual Format) | INCE-USA | Advances in Computational Acoustics and Digital Signal Processing | Vol. 263 (IngentaConnect) | ISO 3744 Sound Power Engineering Grade |
| NOISE-CON 2022 | Lexington, Kentucky | University of Kentucky Vibro-Acoustics Consortium | Manufacturing Noise Abatement and Structural Vibro-Acoustics | Vol. 265 (IngentaConnect) | ASTM E90 Sound Transmission Loss |
| NOISE-CON 2023 | Grand Rapids, Michigan | SAE International (Noise and Vibration Conference) | Automotive Powertrain NVH and Aerospace Aeroacoustics | Vol. 267 (IngentaConnect) | SAE J1400 / ANSI/ASA S12.60 |
| NOISE-CON 2024 | New Orleans, Louisiana | INCE-USA | Environmental Noise, Infrastructure Vibration & Industrial Plant Silencing | Vol. 269 (IngentaConnect) | OSHA 29 CFR 1910.95 / ANSI/ASA S12.2 |
| NOISE-CON 2025 | Stowe, Vermont | INCE-USA | Advanced Acoustic Materials, Metamaterials & Active Vibration Control | Vol. 271 (IngentaConnect) | ASTM E1050 Two-Microphone Impedance Tube |
| NOISE-CON 2026 | Long Beach, California | INCE-USA | Aerospace Noise Certification, Urban Air Mobility & Active Noise Cancellation | Vol. 273 (Scheduled) | FAA 14 CFR Part 36 Aircraft Noise |
Sources
- INCE-USA Conferences and Events Archive (accessed 2026-11-14)
- IngentaConnect INCE Conference Proceedings Repository (accessed 2026-11-14)
- OSHA Occupational Noise Exposure Standard 29 CFR 1910.95 (accessed 2026-11-14)
- FAA 14 CFR Part 36 Noise Standards: Aircraft Type and Airworthiness Certification (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.







