Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
Hand therapy equipment is the set of assessment, splinting, thermal, exercise and adaptive devices used in occupational and physical therapy for the upper extremity. Its FDA classes are mostly Class I, with a few Class II exceptions, and the table below shows which is which.
What hand therapy equipment is
The American Society of Hand Therapists (ASHT) defines hand therapy as “the art and science of evaluating and treating injuries and conditions of the upper extremity (shoulder, arm, elbow, forearm, wrist and hand).” There is no single device category called “hand therapy equipment” in FDA regulations. The equipment is a toolkit drawn from several regulation numbers, each with its own class. For the wider field, see what occupational therapy is.
Who uses it
ASHT describes a hand therapist as an occupational or physical therapist with advanced training in upper extremity conditions. The Certified Hand Therapist (CHT) credential requires a minimum of three years of practice, at least 4,000 hours of treatment for hand and upper extremity disorders, and a certification exam. ASHT lists activity and exercise programs and custom orthosis fabrication among the techniques and tools a hand therapist employs, and names recommendations for adaptive equipment or devices among what a hand therapist can offer. ASHT also notes that a physician’s prescription may be necessary before seeing a hand therapist.
Equipment by clinical task
| Task | Device (regulatory name) | What the regulation says | Class |
|---|---|---|---|
| Strength assessment | Nonpowered dynamometer (21 CFR 888.1250); see hand dynamometers | A mechanical device to measure the pinch and grip muscle strength of a patient’s hand | Class I |
| Range-of-motion assessment | Nonpowered goniometer (21 CFR 888.1520) | A mechanical device to measure the range of motion of joints | Class I |
| Splinting and orthoses | Limb orthosis (21 CFR 890.3475); see splints | Worn on the upper or lower extremities to support, correct or prevent deformities or align body structures; the examples include a hand splint | Class I |
| Thermal devices | Paraffin bath (21 CFR 890.5110); see paraffin baths | A tub of liquid paraffin kept at an elevated temperature in which the patient’s appendages, such as hands or fingers, are placed | Class II |
| Exercise, non-measuring | Nonmeasuring exercise equipment (21 CFR 890.5370); see hand exercisers | Devices for medical purposes such as redeveloping muscles or restoring motion to joints | Class I |
| Exercise, measuring or interactive | Measuring exercise equipment (21 CFR 890.5360) | Manual devices for medical purposes such as redeveloping muscles or restoring motion to joints | Class II |
| Daily-living aids | Adaptive equipment recommended by the therapist; see adaptive equipment in occupational therapy | ASHT lists “recommendations for adaptive equipment or devices to improve function” | Varies by product |
A separate regulation, 21 CFR 890.5410 (powered finger exerciser), is also Class I. For related pages, see physical therapy equipment and Aquaplast thermoplastic splinting material.
How these devices are regulated
Most items above are Class I, which means general controls, and 21 CFR 888.1250, 888.1520, 890.3475 and 890.5370 each state an exemption from premarket notification, subject to the limitations in 21 CFR 888.9 or 890.9 where the regulation says so. The paraffin bath is Class II (special controls), also exempt from premarket notification subject to the 890.9 limitations. Measuring exercise equipment under 21 CFR 890.5360 is Class II; the regulation exempts a measuring exerciser or interactive rehabilitation exercise device for prescription use only from 510(k), subject to the same limitations.
The 890.5360 text gives an exercise bicycle, treadmill and rowing machine as its examples and names no hand or grip item, so it should not be read as covering a hand exerciser unless the product’s own classification says so.
Safe use and handling basics
- Custom orthosis fabrication is one of the tools ASHT lists for hand therapists, so fit and wearing instructions for a splint come from the treating therapist.
- A paraffin bath is a heated device by definition (“maintained at an elevated temperature”), so operate it as the manufacturer’s instructions for use say.
- ASHT says a physician’s prescription may be necessary for hand therapy itself.
Common mistakes
- Treating “hand therapy equipment” as one FDA category. The regulation numbers and classes differ, as the table shows.
- Assuming a class tells you a product is suitable for a given patient. Class describes regulatory controls only.
- Applying the 890.5360 measuring-exerciser wording to hand items that the regulation does not name.
FAQ
Is hand therapy equipment one FDA device category?
No. FDA regulations contain no single category called hand therapy equipment. The items come from several regulation numbers, each with its own class, as the table above shows.
What FDA class is a paraffin bath?
21 CFR 890.5110 classifies a paraffin bath as Class II (special controls), exempt from premarket notification subject to the limitations in 21 CFR 890.9.
Who uses hand therapy equipment?
ASHT describes a hand therapist as an occupational or physical therapist with advanced training in upper extremity conditions; a Certified Hand Therapist has practiced at least three years, with at least 4,000 hours of treatment for hand and upper extremity disorders, and passed a certification exam.
Is a hand dynamometer a Class I device?
A nonpowered dynamometer, a mechanical device to measure the pinch and grip muscle strength of a patient’s hand, is Class I under 21 CFR 888.1250. See hand dynamometers.
Sources
All sources checked 2026-11-01.
- American Society of Hand Therapists, “What is a Hand Therapist?” patient education resource (2022): https://asht.org/sites/asht/files/docs/2022/What%20is%20a%20Hand%20Therapist%202022.pdf
- 21 CFR 888.1250: https://www.ecfr.gov/current/title-21/section-888.1250
- 21 CFR 888.1520: https://www.ecfr.gov/current/title-21/section-888.1520
- 21 CFR 890.3475: https://www.ecfr.gov/current/title-21/section-890.3475
- 21 CFR 890.5110: https://www.ecfr.gov/current/title-21/section-890.5110
- 21 CFR 890.5360: https://www.ecfr.gov/current/title-21/section-890.5360
- 21 CFR 890.5370: https://www.ecfr.gov/current/title-21/section-890.5370
- 21 CFR 890.5410: https://www.ecfr.gov/current/title-21/section-890.5410