The Opera Phenix is a family of automated high-content screening (HCS) microscopes made by Revvity. It images multiwell plates of cells with spinning-disk confocal optics, up to four cameras and water-immersion objectives, then analyses the images with Harmony software to turn cell shape, intensity and texture into numbers. Revvity labels the systems “for research use only”, not for diagnostic procedures. “Phenix” in this context is a product name, not the crystallography program of the same name, which is covered below.
Definition and scope: what does an Opera Phenix do?
An Opera Phenix does one job at scale: it photographs the cells in each well of a 96-, 384- or 1536-well plate in several fluorescence colours (or without any label), and it quantifies what it sees. Revvity’s brochure for the Opera Phenix Plus system describes the use cases as fixed-cell assays such as translocation assays, live-cell assays, fast-response assays such as calcium flux and cardiomyocyte beating, complex 3D cell models, high-throughput phenotyping of libraries of 100,000 compounds or more, and protein-protein interaction studies by CFP-YFP FRET (fluorescence resonance energy transfer).
It is a screening instrument rather than a general-purpose research microscope. A person doing a one-off image of a few slides is usually using a conventional microscope; the Opera Phenix is built for experiments in which hundreds or thousands of wells must be imaged the same way, so that the numbers can be compared across the plate. If you are deciding between optical approaches in general, the page on confocal versus fluorescence microscopy sets out the underlying trade-offs, and spinning-disk versus point-scanning confocal explains why spinning-disk designs suit plate imaging.
Two product generations appear in Revvity’s current documents: the Opera Phenix Plus system and the newer Opera Phenix OptIQ system. Both are described as high-content screening systems with microlens-enhanced spinning-disk confocal optics, Synchrony Optics, up to four cameras and automated water-immersion objectives.
How the Opera Phenix optics work
Spinning-disk confocal imaging
Both systems use a microlens-enhanced Nipkow disk. Revvity describes this as a pinhole disk and a microlens disk spinning in tandem to increase light efficiency, with pinhole spacing chosen to suppress out-of-focus light in 3D samples. The Plus brochure says the increased pinhole-to-pinhole distance reduces out-of-focus noise in thick samples such as microtissues. Spinning-disk optics with synchronised laser excitation and camera exposure are presented as a way to limit photobleaching and phototoxicity in live-cell work.
Synchrony Optics and crosstalk
The central design claim is about speed versus sensitivity. According to the brochure, with other HCS systems a single camera can acquire only one colour at a time, while acquiring several colours simultaneously risks spectral crosstalk. A familiar case is the broad blue emission of DNA stains such as Hoechst 33342 or DAPI, which overlaps the green emission band and limits sensitivity in assays such as nuclear translocation. Revvity’s patented Synchrony Optics use a dual-view design that creates nonoverlapping pinhole patterns in the sample; the brochure states that this minimises crosstalk between adjacent channels by 98% during simultaneous multicolour acquisition with up to four cameras. The OptIQ brochure phrases the figure as “up to 98%” and carries a footnote pointing to a vendor technical note on crosstalk suppression. These are manufacturer figures; they describe vendor test conditions, not an independent benchmark.
Water-immersion objectives and cameras
The systems use automated water-immersion objectives. In the speed technical note Revvity states that it introduced fully automated water immersion lenses on an HCS instrument with the earlier Opera QEHS, and that the Plus version combines customised high-numerical-aperture Zeiss objectives with a water supply and removal system. The note recommends pairing them with dedicated multiwell imaging plates such as Revvity PhenoPlate microplates. The cameras are large-format sCMOS devices on the Plus system; the OptIQ brochure specifies high-quantum-efficiency cameras above 95% QE.
Exposure time and plate time: the arithmetic behind the speed claims
Most pages about the Opera Phenix repeat that it is “fast”. Revvity’s technical note gives enough numbers to work out why, and what to check on your own assay. The data table below sets out its published exposure times for a 40x objective, and the paragraphs that follow give the plate-level rule.
Exposure. Per the note, replacing an air objective with a water-immersion objective cuts exposure time about five-fold because of better light collection. Binning, which combines pixels (BIN2 means 2 by 2 pixels merged into one), cuts exposure by a factor of four at the cost of resolution. Combined, the two give almost a 20-fold reduction: in the vendor’s example, 1,900 ms (40x air, no binning) falls to 100 ms (40x water, BIN2). Revvity says that in its experience 90% of assays perform well with BIN2, and that whether to use full resolution or BIN2 should be settled during assay development by comparing Z’ values under both conditions. Z’ is the assay-quality statistic the note uses for that comparison.
Channels versus cameras. Under the note’s standard test conditions (20x water objective, 100 ms per channel, one field per well, confocal mode, BIN2), the acquisition time for a single channel is the same on one-, two- and four-camera systems. Time only rises when the number of channels exceeds the number of cameras, because the extra channels must then be acquired sequentially. Therefore, on a four-camera system the time for a given plate type is the same whether one, two, three or four channels are imaged. The largest saving the note reports is simultaneous four-channel acquisition on a four-camera instrument versus sequential four-channel acquisition on a one-camera instrument: total time is halved for 384-well and 1536-well plates, and a whole 96-well plate is imaged in under two minutes, up to 1.5 times faster than on a single-camera system.
Versus the predecessor. Compared with the earlier Opera QEHS, a two-channel 384-well epigenetic assay (Alexa Fluor 488 plus Hoechst) was up to six times faster at the same Z’, and the three-times-larger field of view meant four fields per well did the work of ten. In a micronucleus assay the Plus needed eight fields per well versus 24, and Revvity reports a 66% saving in acquisition, 85% in post-acquisition analysis and 77% combined (79% with analysis run in parallel to acquisition). The same note concludes the system can acquire four-channel image sets from 100,000 wells per day, and that z-stack work can add up to several terabytes of data, which is a storage question for the lab, not just a speed question.
Configurations and generations
Opera Phenix Plus configurations
The Plus brochure describes four named configurations and says others are available on request.
| Configuration | What the brochure says |
|---|---|
| Single | Same sensitivity and resolution as the rest of the family; can be upgraded later with additional cameras. |
| Simultaneous | Dual-camera system for multicolour simultaneous confocal acquisition and fast multiplexing. |
| FRET | Five lasers and four cameras, supporting CFP/YFP FRET applications to map protein-protein interactions. |
| Screener | Four cameras and four higher-powered lasers, aimed at screening large libraries. |
Because acquisition time depends on camera count (see above), the choice between Single, Simultaneous and Screener is partly a choice about how many channels per well the experiments need.
Opera Phenix Plus versus Opera Phenix OptIQ
| Feature | Opera Phenix Plus (brochure) | Opera Phenix OptIQ (brochure) |
|---|---|---|
| Confocal optics | Microlens-enhanced Nipkow disk, Synchrony Optics | Microlens-enhanced spinning disk, Synchrony Optics |
| Cameras | Up to four large-format sCMOS cameras | Up to four cameras with above 95% quantum efficiency |
| Imaging frame rate | Faster than 95 fps | 100 fps |
| Environmental control | Temperature, CO2 and humidity (with the liquid handling option) | Temperature, CO2 and humidity, plus 1-21% oxygen for hypoxic or normoxic imaging |
| Autofocus and set-up | Fast laser-based autofocus (technical note) | Improved laser-based autofocus and a new plate set-up wizard |
| Applications highlighted | Fixed and live cells, fast-response assays, 3D models, high-throughput phenotyping, FRET | Organoids, spheroids and organ-on-chip models, cell painting, hypoxia, kinetic imaging with single-cell tracking |
| Software | Harmony with Phenologic.AI | Harmony with Phenologic.AI, a turnkey cell painting analysis tool and a Find Organoids building block |
The OptIQ material emphasises three-dimensional and kinetic work. For background on the profiling method it names, see the page on cell painting, and for the sample types see organoids.
What is Phenix software?
The question has two unrelated answers, and search results mix them.
For the Opera Phenix instrument, the software is Harmony. Revvity describes Harmony as its high-content imaging and analysis software, covering acquisition protocol set-up, automatic image analysis and evaluation of results in a workflow-based interface. The brochure lists more than 30 ready-made analysis solutions, image-analysis building blocks, 3D and XYZ viewers, PlaneMap for z-stack analysis, the PreciScan plug-in (a low-magnification prescan followed by a higher-magnification rescan of the objects found), and machine learning in which the user clicks examples of each cell type. The Phenologic.AI module uses pretrained deep neural networks to find nuclei in brightfield images without a nuclear stain. The OptIQ brochure describes the building blocks as four steps: find objects, calculate properties, classify objects and report results, including dose-response curves with EC50/IC50 and z-prime calculations.
Phenix the structure-determination suite is a different product. The Phenix project (phenix-online.org) describes Phenix as a comprehensive software package for macromolecular structure determination from X-ray, neutron and electron diffraction and cryo-EM data. It has nothing to do with Revvity’s instrument. Its recommended citation is Liebschner et al., Acta Crystallographica Section D 75, 861-877 (2019), doi:10.1107/S2059798319011471. If you are looking for crystallographic model building, you want that site; if you are looking for plate imaging, you want Harmony.
Where it matters for labs and core facilities
Revvity’s own technical note observes that published high-content screens often rely on only one or two image features rather than multiparametric single-cell results (citing Singh et al. 2014), and positions the Opera Phenix Plus for multiparametric phenotypic screens. A neutral account of what multiparametric profiling involves is the open-access Nature Methods paper “Data-analysis strategies for image-based cell profiling” (Caicedo et al., 2017), which is a useful independent reference when planning analysis rather than relying on the vendor’s description.
Used as a checklist for a facility conversation, the sourced features above translate into concrete questions. None of them is a recommendation; each follows from a documented property of the instrument.
- How many cameras and lasers does this particular unit have? Plate time depends on camera count, and FRET needs a specific laser and camera set-up.
- Is the liquid handling option fitted? The brochure says it handles 20 µL and 200 µL Revvity tips in 1 µL increments, with one compound plate, one reservoir, up to two additions per well and 96- and 384-well plates, and that it requires the environmental control option.
- Which objectives are installed, and has your assay been tested at BIN2 versus full resolution by comparing Z’?
- Which Harmony analysis solutions and plug-ins (PreciScan, Phenologic.AI) are licensed for your use?
- Where will the images be stored, and who handles the data volume for z-stacks? Harmony results can also be exported to other Revvity software, per the brochure.
- Are your plates compatible? The note recommends dedicated imaging plates with water-immersion objectives.
Common misunderstandings
- “Phenix software” means one thing. It does not; see the section above.
- More channels always means a longer run. Not up to the number of cameras installed; beyond that, channels are acquired sequentially.
- The 98% crosstalk figure is an instrument-independent fact. It is the vendor’s figure for its own optics and test samples.
- It is a clinical or diagnostic instrument. Revvity states that the systems are for research use only and not for use in diagnostic procedures.
- Speed figures transfer to any assay. The speed numbers come from defined test conditions (for example 100 ms per channel and one field per well); your exposure and field counts determine your plate time.
Frequently asked questions
What is Phenix software?
For the Opera Phenix instrument it is Harmony, Revvity’s high-content imaging and analysis software. The separate Phenix suite at phenix-online.org is a macromolecular structure-determination package unrelated to the instrument.
What does an Opera Phenix do?
It automatically images multiwell plates of cells with spinning-disk confocal optics and analyses the images for features such as morphology, intensity and texture, so that treatments or phenotypes can be compared across many wells. It supports fixed-cell, live-cell and 3D assays, and with an optional pipettor module it can measure responses immediately after compound addition.
What is the difference between the Opera Phenix Plus and the Opera Phenix OptIQ?
Both use Synchrony Optics and up to four cameras. According to the brochures, the OptIQ adds 1-21% oxygen control, a plate set-up wizard, kinetic imaging with single-cell tracking and an emphasis on organoids, organ-on-chip models and cell painting.
Can an Opera Phenix image live cells without dyes?
Revvity states that the Plus offers a digital phase contrast mode for live cells without fluorescent labels, and that Phenologic.AI can identify nuclei in brightfield images without a nuclear stain.
Sources
- Revvity, Opera Phenix Plus high-content screening system brochure (2025), read 2026-11-19.
- Foitzik, Prange, Boettcher and Schreiner, Revvity technical note: Speed, Opera Phenix Plus technical performance (2023), read 2026-11-19.
- Revvity, Opera Phenix OptIQ high-content screening system brochure, read 2026-11-19.
- Phenix, macromolecular structure determination software (phenix-online.org), read 2026-11-19.
- Caicedo et al., Data-analysis strategies for image-based cell profiling, Nature Methods 14, 849-863 (2017), record checked 2026-11-19.
Data: Exposure time per image by objective type and pixel binning, 40x objective (Revvity Opera Phenix Plus technical note)
Published exposure times for a 40x air objective versus a 40x water-immersion objective, each with and without 2x2 binning, with the reduction factor relative to air without binning calculated from the published millisecond values. Compiled from a manufacturer technical note, so the values reflect the vendor's test sample and are not an independent benchmark.
Period covered: 2023.
| Condition | Objective | Binning | Exposure time (ms) | Reduction versus air objective without binning (x (calculated)) |
|---|---|---|---|---|
| 40x air, BIN1 | 40x air | BIN1 | 1900 | 1 |
| 40x air, BIN2 | 40x air | BIN2 | 480 | 3.96 |
| 40x water, BIN1 | 40x water immersion | BIN1 | 410 | 4.63 |
| 40x water, BIN2 | 40x water immersion | BIN2 | 100 | 19 |
Sources
- Revvity technical note: Speed, Opera Phenix Plus high-content screening system technical performance (accessed 2026-11-19)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.