Written and maintained by CASRAI Editorial Board
Published
On this page
An oxygen SDS identifies oxygen as an oxidizing gas: it can intensify a fire even though it is not itself combustible. Compressed oxygen also presents a pressure hazard; refrigerated liquid oxygen adds a cryogenic injury hazard. The supplier sheets and comparison below distinguish those forms and connect their classifications to laboratory controls.
Short answer and oxygen SDS downloads
Use the safety data sheet that matches the supplier, product identifier, physical form and jurisdiction on the container. These manufacturer documents cover the principal forms relevant to laboratory staff and EHS officers:
- Airgas oxygen SDS 001043, compressed gas.
- Airgas refrigerated liquid oxygen SDS 001190.
- Sigma-Aldrich oxygen SDS, product 295604, United States.
- Linde Gas GmbH oxygen, compressed SDS 000010021701, Austria.
The downloadable data table below compares document identity and hazard classification across these sheets. It keeps the liquid product separate rather than presenting every oxygen container as the same pressure-gas entry. The dates identify the documents used for this comparison; the supplier and product identifiers establish which document belongs with a particular container.
Definition and scope
An oxygen safety data sheet describes the hazards and protective measures for the supplied chemical. Oxygen is O2, CAS 7782-44-7. The ILO/WHO International Chemical Safety Card 0138 describes compressed oxygen as an odorless gas and a strong oxidant. Its storage guidance separates it from combustible substances and reducing agents. Familiarity with oxygen in air does not remove those properties from an oxygen supply.
The distinction between chemical identity and supplied form is essential. Compressed oxygen and refrigerated liquid oxygen have the same CAS number, but their containers and hazard statements differ. A CAS-number match alone therefore cannot establish that a sheet describes the product in hand. For a broader explanation of document organization, see how to read the 16 sections of a safety data sheet.
In United States laboratories, OSHA 29 CFR 1910.1200(b)(3) requires incoming hazardous-chemical labels to remain intact and received SDSs to be maintained and readily accessible to employees during each workshift in their work areas. It also requires employee information and training within the laboratory provisions. Saving a PDF to a procurement record is useful documentation, but it does not by itself establish that staff can obtain it when needed.
This guide addresses chemical hazard communication and laboratory handling controls. It does not establish a gas grade’s suitability for a particular application, prescribe treatment, or replace the supplier’s complete sheet and the workplace assessment.
How an oxygen SDS is used in practice
Read the hazard and precaution statements together
The Airgas compressed-gas sheet identifies an oxidizing gas, category 1, and a gas under pressure in compressed form. Its signal word is Danger. H270 means “May cause or intensify fire; oxidizer.” H280 means “Contains gas under pressure; may explode if heated.” These describe different hazards: increased combustion and stored pressure. Neither statement can substitute for the other.
The precaution codes add the controls that the hazard names alone leave implicit. In the Aldrich sheet, P220 concerns separation from clothing and combustible materials, while P244 addresses oil and grease on reduction valves. P370+P376 makes stopping a leak during a fire conditional on safety. P410+P403 addresses sunlight protection and ventilated storage. These are explanations of the codes, not replacement label wording; retain the complete statements on the supplied label.
Translate classification into equipment and workplace controls
EIGA’s Fire Hazards of Oxygen and Oxygen-Enriched Atmospheres explains why oxygen service needs particular attention to compatibility and cleanliness. Greater oxygen concentration and pressure can make ignition easier and combustion more vigorous. Its discussion includes leaks, unsuitable materials, and incorrect equipment design or maintenance as routes to an oxygen fire. A pressure rating alone is therefore an incomplete description of equipment suitability.
The same EIGA guidance emphasizes that people cannot detect oxygen enrichment by smell, taste or appearance. Ventilation and atmospheric analysis address a condition that ordinary senses cannot reliably reveal. Its definition of an oxygen-enriched atmosphere includes oxygen above 23.5% by volume at sea level, or a partial pressure above 175 torr. That definition should not be converted into a universal laboratory alarm specification without the applicable assessment and rules.
A useful documentary review asks whether the hazard statement, equipment designation, ventilation assessment and local emergency arrangements tell a consistent story. This joins information scattered across the SDS rather than treating section 2 as a complete operating plan. General compressed gas cylinder safety provides the surrounding context for cylinder damage and handling hazards.
Compressed oxygen, liquid oxygen and related classifications
Refrigerated liquid oxygen retains the oxidizing hazard and introduces a severe cold-contact hazard. Airgas SDS 001190 uses H281 for refrigerated gas and warns of cryogenic injury. Its P282 precaution calls for cold-insulating gloves and eye or face protection. The sheet also warns that combustible material exposed to liquid oxygen can explode upon ignition or impact. A compressed-gas summary that omits this distinction misses the defining additional hazard of the liquid product.
Several classification systems can appear in one SDS. Keep their purposes separate:
- GHS hazard classification: the manufacturer identifies the physical hazard, such as oxidizing gas category 1 and compressed or refrigerated liquefied gas.
- Storage class: Aldrich lists 2A, Gases, in section 7 for product 295604. This is a supplier-reported storage designation, not permission to place oxygen with every other gas.
- Transport identification: the Airgas sheets distinguish UN1072 for compressed oxygen from UN1073 for refrigerated liquid oxygen. Their transport entries serve a different purpose from the workplace hazard category.
Numbers can look deceptively interchangeable when separated from their headings. Category 1 in an oxidizing-gas classification is not transport division 2.2, and neither is the supplier’s storage class 2A. Preserve the system name alongside the value in an inventory or risk assessment. The comparison dataset does this explicitly, so a copied cell retains its context.
Illustrative composite: a document mismatch. A laboratory record identifies refrigerated liquid oxygen, while its attached Airgas document is SDS 001043 for compressed gas. The CAS number agrees, but that is only the chemical identity check. Comparing the supplied form with SDS 001190 exposes the missing H281 cold-hazard information. The appropriate documentary correction is to associate the matching supplier sheet with the record and review the controls against that form. This example does not establish a transfer method or authorize handling; it shows why a matching chemical name is insufficient evidence that the safety documentation is complete.
Where oxygen SDS controls matter for laboratories
Storage and incompatibilities
The ILO/WHO card places the incompatibility problem in chemical terms: oxygen reacts with combustible and reducing materials and can create a fire or explosion hazard. Segregation should follow those properties. An inventory organized only by chemical name or a broad “gas” category cannot express that distinction. The site’s chemical storage compatibility and segregation guide explains how hazard groups fit into a wider storage plan.
OSHA’s oxygen-fuel gas welding and cutting standard gives a specific dimensional rule. Under 29 CFR 1910.253(b)(4)(iii), oxygen cylinders in storage require separation from fuel-gas cylinders or combustible materials by at least 20 feet (6.1 m), or by a noncombustible barrier at least 5 feet (1.5 m) high with a fire-resistance rating of at least half an hour. Cite the welding-and-cutting scope with the dimensions. The SDS and the applicable local requirements still matter when assessing a research laboratory.
The same OSHA standard prohibits oily or greasy substances on oxygen apparatus and handling oxygen apparatus with oily hands or gloves. This connects cleanliness to storage and equipment compatibility, rather than treating oil contamination as a cosmetic housekeeping issue. A barrier specification does not cancel the need to control combustible contamination.
PPE belongs to the task assessment
The Linde Austria sheet calls for a documented assessment to select protection appropriate to each work area. Its compressed-gas recommendations include eye protection to EN 166, working gloves for mechanical handling risks, and safety footwear when moving containers. It also addresses ventilation and gas detection where quantities of oxidizing gas may be released. These recommendations belong to that sheet and its jurisdiction; they should not be presented as one universal PPE list for all oxygen activities.
In contrast, the liquid-oxygen sheet’s cold-insulating protection addresses a thermal hazard. Mechanical handling protection and cold-contact protection answer different questions. An EHS review should identify which exposure or physical task each item addresses rather than assuming that any glove or any cylinder-related eyewear recommendation covers both forms.
Container return, disposal and emergency planning
Airgas directs empty pressure vessels back to the supplier and warns against puncturing or incinerating the container. Linde likewise specifies disposal of its container through the supplier. Read the disposal section separately from the abbreviated label precautions: a brief label entry does not define the container-return route. An apparently empty cylinder is still a pressure vessel requiring the supplier’s arrangements.
For emergency planning, distinguish a documentary review from intervention at a leaking container. EIGA addresses trained personnel, suitable oxygen-service equipment, ventilation and maintained escape routes. Its oxygen-fire discussion also warns that entering an enriched atmosphere to pull out a burning person can expose the would-be rescuer to fire. The SDS’s conditional leak-stopping language must remain conditional; it is not a general instruction for untrained staff to approach a release.
Common misunderstandings and a document review checklist
“Nonflammable means no fire hazard.” The ILO/WHO card explicitly distinguishes oxygen’s own noncombustibility from its ability to enhance combustion of other substances. Read the oxidizer warning alongside any nonflammable-gas transport description. They describe compatible facts rather than a contradiction.
“A storage code supplies the complete storage plan.” Aldrich’s 2A designation identifies a storage class; its own section 7 still calls for separation from combustible materials and ignition sources. Retaining the code while dropping those conditions loses the practical meaning of the sheet.
“One oxygen PDF covers every oxygen product.” The cross-supplier data table separates compressed and refrigerated liquid forms and identifies the regulatory context of the documents. Agreement on the oxidizer classification does not make their regional wording, product identifiers or cold-hazard precautions interchangeable.
The following review checklist is an editorial synthesis of the manufacturer sheets and OSHA’s laboratory communication provisions. It checks documentation completeness without supplying a cylinder operating procedure:
- Identity: supplier, product identifier and physical form agree with the container and the SDS identification section.
- Hazards: the inventory preserves oxidizer and pressure or refrigerated-gas classifications, rather than recording only “oxygen.”
- Controls: the assessment considers compatibility, contamination, ventilation, storage segregation and the PPE applicable to the task.
- Availability: laboratory employees can obtain the received sheet during their workshift, and the incoming label remains intact.
- End of use: the record identifies the supplier’s container-return arrangements, distinct from the product’s abbreviated label disposal entry.
Sources
- Airgas, Oxygen SDS 001043, revision 2025-03-28. Checked 2026-11-16.
- Airgas, Oxygen, Refrigerated Liquid SDS 001190, revision 2025-03-28. Checked 2026-11-16.
- Sigma-Aldrich, Oxygen 295604 US SDS, version 8.4, revision 2025-04-28. Checked 2026-11-16.
- Linde Gas GmbH, Oxygen, compressed 000010021701, Austria, revision 2022-07-14. Checked 2026-11-16.
- ILO/WHO, International Chemical Safety Card 0138: Oxygen. Checked 2026-11-16.
- OSHA, 29 CFR 1910.1200: Hazard Communication, especially laboratory provisions (b)(3). Checked 2026-11-16.
- OSHA, 29 CFR 1910.253: Oxygen-fuel gas welding and cutting. Checked 2026-11-16.
- EIGA, Doc 04/26: Fire Hazards of Oxygen and Oxygen-Enriched Atmospheres. Checked 2026-11-16.
Data: Oxygen SDS comparison by supplier, jurisdiction and physical form
Original comparison compiled from four manufacturer safety data sheets. Each row identifies the source document and jurisdiction, supplied physical form, oxidizing-gas category, pressure-gas classification and hazard statement codes. Revision dates identify the compared documents; rows describe those documents rather than certifying future revisions.
| Supplier and SDS identifier | Jurisdiction / framework | Supplied form | Oxidizing-gas category | Pressure-gas classification | Hazard codes | SDS revision date |
|---|---|---|---|---|---|---|
| Airgas 001043 | United States / OSHA HazCom | Gas | 1 | Compressed gas | H270; H280 | 2025-03-28 |
| Airgas 001190 | United States / OSHA HazCom | Refrigerated liquid | 1 | Refrigerated liquefied gas | H270; H281 | 2025-03-28 |
| Sigma-Aldrich 295604 | United States / OSHA HazCom | Compressed gas | 1 | Compressed gas | H270; H280 | 2025-04-28 |
| Linde Gas GmbH 000010021701 | Austria / REACH and CLP | Compressed gas | 1 | Compressed gas | H270; H280 | 2022-07-14 |
Sources
- Airgas Oxygen SDS 001043 (accessed 2026-11-16)
- Airgas Oxygen, Refrigerated Liquid SDS 001190 (accessed 2026-11-16)
- Sigma-Aldrich Oxygen 295604 US SDS (accessed 2026-11-16)
- Linde Gas GmbH Oxygen, compressed 000010021701 Austria SDS (accessed 2026-11-16)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.