Skip to main content
v2026.11,986 entries · CC-BY 4.0

Petroleum Ether Boiling Point and Laboratory Solvent Properties

Petroleum ether boils across distinct commercial temperature cuts from 30 °C to 120 °C. Review physical properties, bench protocols, and solvent safety.

Written and maintained by CASRAI Editorial Board

Published

On this page

Petroleum ether does not have a single fixed boiling point because it is not a pure chemical compound; instead, it is a complex mixture of volatile aliphatic hydrocarbons that boils across distinct commercial temperature ranges between 30 °C and 120 °C. Standard laboratory reagent grades are classified into narrow distillation cuts, most commonly 30–40 °C, 35–60 °C, 40–60 °C, 60–80 °C, 80–100 °C, and 100–120 °C (ligroin). Across these fractions, liquid density ranges from 0.625 to 0.740 g/cm³ at 20 °C, the dielectric constant spans 1.88 to 1.95, and the Snyder polarity index remains virtually non-polar at 0.1, making petroleum ether an essential bench solvent for non-polar liquid-liquid extractions, flash chromatography, and rapid rotary evaporation.

What Is Petroleum Ether? Definition, Composition, and Chemical Identity

In laboratory practice, petroleum ether (cataloged under CAS Registry Number 8032-32-4, or CAS 64742-49-0 for hydrotreated light fractions) is a purified, volatile mixture of light aliphatic hydrocarbons. Despite its common name, petroleum ether contains zero ether functional groups (R–O–R′). It consists entirely of saturated linear, branched, and cyclic alkanes, predominantly pentane (C5H12), hexane (C6H14), and heptane (C7H16) isomers. The historical term ‘ether’ was assigned by nineteenth-century chemists to describe its extreme physical lightness, high vapor pressure, and rapid evaporation without oily residue, evoking the classical concept of volatile ‘aether’ rather than modern chemical functional groups.

Because petroleum ether is an Unknown or Variable Composition, Complex Reaction Products and Biological Materials (UVCB) substance, its exact composition varies by crude petroleum source and distillation parameters. Light cuts (such as 30–40 °C) are dominated by 2-methylbutane and n-pentane, standard bench grades (40–60 °C) incorporate 2-methylpentane and 3-methylpentane, and higher cuts (60–80 °C) contain linear n-hexane and methylcyclopentane. The complete absence of oxygenated functional groups dictates its chemical inertness, high hydrophobicity, and inability to act as a hydrogen-bond donor or acceptor.

Commercial Boiling Point Cuts and Distillation Fractions

Because petroleum ether is a multi-component hydrocarbon blend, chemical manufacturers isolate it using fractional distillation between defined boiling thresholds rather than isolating a single chemical species. When designing experiments or ordering reagents, researchers must always designate the specific distillation cut, as the boiling range determines evaporation rates, vacuum settings, and flammability parameters.

  • 30–40 °C Fraction (Low-Boiling Grade): Primarily composed of isopentane (boiling point 27.8 °C) and n-pentane (boiling point 36.1 °C). This cut exhibits high room-temperature vapor pressure and is chosen for extracting thermolabile natural products that degrade at elevated temperatures during solvent removal.
  • 35–60 °C and 40–60 °C Fractions (Standard Bench Grades): The most common general-purpose laboratory cuts. Containing balanced ratios of pentanes and light hexane isomers, these grades offer rapid evaporation without the aggressive flash-boiling tendencies of pure pentane. They serve as the default solvent for routine reaction workups, precipitate washing, and column chromatography.
  • 60–80 °C Fraction (Hexane-Equivalent Grade): Dominated by hexane isomers and isoheptanes. Boils in a range comparable to pure n-hexane (68.7 °C) and serves as an economical alternative for large-scale extractions and recrystallizations where lower volatility reduces evaporative loss.
  • 80–100 °C Fraction (Heptane-Equivalent Grade): Composed mainly of heptane isomers and methylcyclohexane. This cut is selected for continuous hot Soxhlet extractions and reflux protocols requiring sustained heating at 80–90 °C.
  • 100–120 °C Fraction (Ligroin / Mineral Spirits Cut): Historically termed ligroin, this fraction contains C7 to C9 hydrocarbons. It provides a non-polar medium for industrial defatting, high-temperature crystallization, and specialized organometallic procedures.

The data table below compares the physical specifications, density profiles, refractive indices, and bench distillation parameters across each of these commercial petroleum ether grades.

Petroleum Ether Density, Refractive Index, and Physical Constants

Understanding petroleum ether density is critical when planning two-phase extractions and volumetric transfers. Unlike water or dense halogenated solvents, all petroleum ether fractions have densities substantially below 1.0 g/cm³.

At standard laboratory reference temperatures (20 °C), petroleum ether density ranges from 0.625 g/cm³ for the 30–40 °C cut to 0.740 g/cm³ for the 100–120 °C cut. For the standard 40–60 °C grade, measured density typically sits between 0.640 and 0.660 g/mL (nominal 0.650 g/mL). Because petroleum ether is approximately 35% lighter than water, it invariably separates as the top (organic) layer in any aqueous-organic extraction in a separatory funnel. This pronounced density difference facilitates rapid phase clearance and sharp layer boundaries.

The refractive index (n20/D) also correlates with carbon number and boiling range. Light pentane-rich cuts display a refractive index near 1.353, 40–60 °C cuts measure approximately 1.358, and heavier fractions approach 1.400. Chemists use benchtop refractometers to verify solvent purity and detect evaporative aging; an elevated refractive index indicates that lighter C5 hydrocarbons have volatilized from an unsealed bottle. Additionally, petroleum ether has a high thermal expansion coefficient (~0.0013 K⁻¹ at 20 °C). Storage bottles filled completely in a 4 °C cold room can build hydraulic pressure when transferred to ambient bench temperatures (22 °C), requiring adequate bottle headspace.

Petroleum Ether Polarity, Dielectric Constant, and Miscibility

Solvent selection in organic synthesis and analytical chromatography relies on quantitative metrics including petroleum ether polarity, the dielectric constant, and mutual miscibility profiles. In Lloyd R. Snyder’s solvent selectivity framework, the petroleum ether polarity index (P′) is 0.1. On Snyder’s scale—which ranks n-pentane at 0.0, n-hexane at 0.1, ethyl acetate at 4.4, and water at 10.2—petroleum ether occupies the extreme non-polar boundary. It lacks dipole moments (μ ≈ 0.0 D) and cannot participate in hydrogen bonding.

The petroleum ether dielectric constant (relative permittivity, ε) ranges from 1.88 to 1.95 at 20 °C, matching pure n-hexane (1.88) and n-pentane (1.84). This minimal polarizability prevents petroleum ether from solvating ionic charges or stabilizing polar transition states. Consequently, inorganic salts, mineral acids, and polar organic reagents remain completely insoluble, allowing researchers to selectively precipitate ionic salts (such as amine hydrochlorides) directly from reaction mixtures.

Regarding petroleum ether miscibility, its non-polar aliphatic composition dictates clear operational boundaries:

  • Immiscibility with Aqueous and Highly Polar Media: Petroleum ether is insoluble in water (solubility under 50 mg/L at 20 °C) and completely immiscible with ethylene glycol, formamide, and glycerol. It displays very limited partial miscibility with pure dimethyl sulfoxide (DMSO) and dimethylformamide (DMF), enabling extraction of non-polar compounds from polar crude mixtures.
  • Complete Miscibility with Non-Polar and Mid-Polar Solvents: Petroleum ether is miscible in all proportions with diethyl ether, tert-butyl methyl ether (MTBE), chloroform, dichloromethane (DCM), toluene, ethyl acetate, tetrahydrofuran (THF), acetone, and anhydrous lower alcohols (such as ethanol and isopropanol). However, with anhydrous methanol, a miscibility gap can occur at cooler temperatures, separating into two liquid phases.

Laboratory Bench Applications: Rotovap, Extraction, and Chromatography

Petroleum ether fills three primary roles in experimental laboratories: rotary evaporation, liquid-liquid extractive workups, and chromatographic purification.

1. Rotary Evaporation Protocol and Vacuum Management

Evaporating petroleum ether requires careful vacuum regulation due to its high volatility. The 40–60 °C cut possesses a vapor pressure of 40 to 50 kPa at 20 °C. Pulling unrestricted vacuum will cause violent bumping and foam entrainment into the condenser coils.

When operating a rotary evaporator, apply the standard ‘Rule of 20’: set the heating bath to 40 °C, target a vapor temperature of 20 °C, and maintain the cooling chiller between 0 °C and 10 °C. Under these conditions, set the vacuum controller to 250–300 mbar for a 40–60 °C grade (or 350–400 mbar for a 30–40 °C grade). Always use a bump trap, initiate rotation at 120–150 rpm prior to pulling vacuum, and step down pressure in 25 mbar increments until smooth condensation forms on the lower condenser coils.

2. Liquid-Liquid Extractive Separations

In synthetic workups, petroleum ether is widely chosen over diethyl ether or dichloromethane. Because its density (~0.65 g/mL) is much lower than aqueous salt solutions (1.1–1.2 g/mL), it rapidly forms the upper layer in a separatory funnel. Unlike chlorinated solvents, which form the lower layer and often create persistent emulsions, petroleum ether sheds aqueous droplets cleanly, effectively extracting non-polar lipids, hydrocarbons, and unreacted reagents.

3. Thin-Layer and Flash Column Chromatography

In silica gel chromatography, petroleum ether provides the standard non-polar mobile phase. Because its elutropic solvent strength on silica is essentially zero (E° = 0.00 to 0.01), pure petroleum ether holds polar and semi-polar solutes near the baseline (Rf ≤ 0.05). By blending petroleum ether with ethyl acetate according to principles of chromatographic elution, researchers modulate solvent strength across 95:5, 80:20, or 50:50 ratios, targeting analyte retention factors (Rf) between 0.25 and 0.40 for clean resolution.

Solvent Selection: Petroleum Ether vs. Pure Hexane, Pentane, and Diethyl Ether

Bench scientists routinely evaluate petroleum ether against single-component hydrocarbons and diethyl ether, balancing cost, volatility, and laboratory safety.

Compared to pure n-hexane, petroleum ether offers cost advantages and lower chronic neurotoxicity. Reviewing the hexane boiling point and laboratory properties indicates that pure n-hexane (boiling point 68.7 °C) requires extensive commercial purification. Crucially, n-hexane is metabolized in vivo to 2,5-hexanedione, a reactive diketone responsible for toxic peripheral neuropathy. In contrast, 40–60 °C petroleum ether consists largely of branched C5 and C6 alkanes (such as 2-methylbutane and 2-methylpentane), which follow alternative metabolic pathways that do not yield 2,5-hexanedione, reducing chronic neurotoxicity hazards during routine bench use.

Compared to the single-component pentane boiling point reference (36.1 °C), 40–60 °C petroleum ether is less prone to flash-evaporating in TLC developing chambers during warm weather, providing steadier retention factors. Relative to heptane boiling point datasheet values (98.4 °C), petroleum ether strips faster under mild vacuum without subjecting delicate products to high bath temperatures.

Finally, researchers must distinguish petroleum ether from diethyl ether (boiling point 34.6 °C). While both liquids share similar boiling points and water immiscibility, they exhibit opposing chemical behavior. Diethyl ether is a coordinating Lewis base that solvates metal cations in Grignard reagents and organolithium reactions. Petroleum ether has zero Lewis basicity and cannot support Grignard reagent formation. Substituting petroleum ether for diethyl ether in organometallic reactions causes immediate failure.

Chemical Safety, Flammability, and Storage at the Bench

Petroleum ether presents significant flammability risks requiring rigorous engineering controls and containment protocols.

  • Low Flash Point and Flammability: Commercial cuts (35–60 °C and 40–60 °C) have closed-cup flash points below −40 °C (−40 °F) and autoignition temperatures between 240 °C and 280 °C. The lower explosive limit is approximately 1.0% and the upper explosive limit is 6.0% by volume in air. Flammable vapor mixtures form continuously over open liquid surfaces at ambient room temperature.
  • Vapor Density and Flashback Hazard: Petroleum ether vapor is 2.5 to 3.0 times denser than air. Released vapors pool along bench surfaces, flow into floor drains, and travel toward remote ignition sources such as hotplates. All handling of open vessels must take place inside a certified chemical fume hood operating at a minimum face velocity of 100 feet per minute (0.5 m/s).
  • Static Dissipation and Grounding: As non-conductive hydrocarbons with dielectric constants below 2.0, petroleum ether readily accumulates electrostatic charge during pouring or pumping through non-grounded lines. When transferring volumes exceeding 4 liters, always bond and ground metal dispensing and receiving vessels.
  • Absence of Peroxide Formation: A common misconception is that petroleum ether forms explosive organic peroxides during storage, like diethyl ether or tetrahydrofuran. Because petroleum ether contains no ether oxygen atoms, it does not undergo autoxidation to form organic peroxides. Peroxide test strips and inhibitors (such as BHT) are not required. Nevertheless, containers must remain tightly capped in flammables cabinets to prevent vapor leakage and pressure build-up.
  • Personal Protective Equipment (PPE): Standard thin nitrile gloves (4 mil) offer minimal resistance to petroleum ether, with breakthrough times under 4 minutes. In the event of an accidental splash, strip and discard gloves immediately. For continuous handling, select heavy nitrile, Viton, or laminated barrier gloves.

Worked Bench Protocols and Troubleshooting Guide

This protocol details the concentration of a crude non-polar extract using 40–60 °C petroleum ether, followed by solutions for common bench difficulties.

Step-by-Step Rotary Evaporation Procedure

  1. Drying and Filtration: Dry the organic layer over anhydrous sodium sulfate (Na2SO4) for 15 minutes. Gravity-filter the extract through fluted paper into a round-bottom flask, filling to no more than 50% capacity.
  2. Apparatus Setup: Verify that the chiller recirculates coolant at 5 °C and the water bath is steady at 35–40 °C. Fit a clean bump trap between the vapor duct and the flask using a Keck clip.
  3. Immersion and Rotation: Mount the flask, engage the rotation drive at 120 rpm, and close the vacuum stopcock.
  4. Controlled Depressurization: Set the vacuum controller to 400 mbar. Allow pressure to stabilize for 30 seconds, then lower the setpoint in 25 mbar increments until condensation appears on the glass coils (typically 280–300 mbar).
  5. Completion: When condensation ceases, raise the flask from the bath, vent the system to atmospheric pressure, halt rotation, unclip the flask, and wipe outer glass surfaces before weighing.

Bench Troubleshooting and Recovery

  • Emulsions During Extraction: Agitation with aqueous phases containing surfactants can produce milky emulsions. Remedy: Add 5–10 mL of saturated aqueous sodium chloride (brine) to increase ionic strength, or filter the mixture through a pad of Celite to rupture interfacial films.
  • Solvent Bumping on Rotovap: Abrupt depressurization causes liquid to boil violently into the bump trap. Remedy: Vent the system immediately, increase rotation speed to 160 rpm to thin the boundary layer, and raise the starting vacuum setpoint to 350 mbar. Rinse the bump trap with fresh petroleum ether back into the flask to reclaim product.
  • TLC Spot Streaking: Polar or basic analytes streak along the silica plate in petroleum ether / ethyl acetate mobile phases. Remedy: Pre-equilibrate the chamber with filter-paper lining for 5 minutes. For basic compounds, add 0.5% v/v triethylamine; for carboxylic acids, add 0.5% v/v acetic acid to suppress ionization.

Frequently asked questions

What is the boiling point of petroleum ether?

Petroleum ether does not have a single fixed boiling point because it is a mixture of volatile aliphatic hydrocarbons rather than a single compound. Instead, it boils across distinct commercial temperature cuts ranging from 30 °C to 120 °C. The most common bench reagent grades are the 35–60 °C and 40–60 °C cuts, while higher grades include 60–80 °C and 80–100 °C.

Why is petroleum ether called an ether if it contains no ether group?

The name petroleum ether is an archaic chemical term established in the 1800s. Early chemists used the word ether (derived from the Greek aether) to describe any liquid that was exceptionally light, highly volatile, and evaporated rapidly into the atmosphere without leaving an oily residue. Chemically, petroleum ether contains zero ether linkages (R–O–R′) and consists solely of saturated hydrocarbons.

What is the density of petroleum ether?

The density of petroleum ether varies from 0.625 to 0.740 g/cm³ at 20 °C depending on the boiling range. For the standard 40–60 °C laboratory cut, the nominal density is approximately 0.650 g/mL (typically 0.640 to 0.660 g/mL). Because this density is substantially lower than water (1.00 g/mL), petroleum ether always forms the upper layer in aqueous liquid-liquid extractions.

Does petroleum ether form explosive peroxides during storage?

No, petroleum ether does not form explosive organic peroxides during ambient shelf storage. Unlike true ethers such as diethyl ether, diisopropyl ether, or tetrahydrofuran (THF), petroleum ether contains no ether oxygen atoms capable of facilitating alpha-carbon autoxidation. However, it must still be stored in a tightly sealed container inside a dedicated flammables safety cabinet to prevent volatile vapor leakage and extreme fire risks.

How do you set a rotary evaporator for petroleum ether 40–60 °C?

When concentrating petroleum ether 40–60 °C on a rotary evaporator, maintain a water bath temperature of 35 °C to 40 °C, set the chiller condenser between 0 °C and 10 °C, and regulate the vacuum setpoint between 250 mbar and 300 mbar. Avoid applying full house vacuum immediately, as sudden depressurization will cause violent solvent bumping into the vapor duct.

What is the polarity index and dielectric constant of petroleum ether?

Under Snyder’s solvent classification scale, petroleum ether has a polarity index (P′) of 0.1, making it an essentially non-polar solvent comparable to pure n-pentane (0.0) and n-hexane (0.1). Its dielectric constant (relative permittivity) is approximately 1.88 to 1.95 at 20 °C, indicating negligible electrical polarizability and an inability to dissolve ionic or highly polar organic molecules.

Sources

  • National Center for Biotechnology Information (NCBI) PubChem — Petroleum Ether Compound Profile (CAS 8032-32-4 / CID 23005): https://pubchem.ncbi.nlm.nih.gov/compound/23005 (accessed 2026-11-15)
  • National Oceanic and Atmospheric Administration (NOAA) CAMEO Chemicals — Petroleum Naphtha / Petroleum Ether Chemical Datasheet (ID 4383): https://cameochemicals.noaa.gov/chemical/4383 (accessed 2026-11-15)
  • Centers for Disease Control and Prevention (CDC) NIOSH Pocket Guide to Chemical Hazards — VM & P Naphtha (NPGD #0669): https://www.cdc.gov/niosh/npg/npgd0669.html (accessed 2026-11-15)
  • Sigma-Aldrich / MilliporeSigma — Petroleum Ether Reagent Grade Specifications and Distillation Fractions: https://www.sigmaaldrich.com/US/en/substance/petroleumether123458032324 (accessed 2026-11-15)
  • Fisher Scientific / Thermo Scientific Chemicals — Petroleum Ether 40-60 °C Technical Specifications: https://www.fishersci.com/shop/products/petroleum-ether-40-60-c-extra-pure-thermo-scientific-chemicals/11488660 (accessed 2026-11-15)
  • LSU Macromolecular Chemistry & Snyder Solvent Database — Solvent Polarity Index and Selectivity Parameters: https://www.lsu.edu/science/chemistry/facilities/macromolecular/chromatography/solvent_properties.php (accessed 2026-11-15)
  • Heidolph Instruments — Rotary Evaporator Distillation Guide and Solvent Parameters: https://heidolph-instruments.com/en/knowledge/solvent-guide/ (accessed 2026-11-15)

Data: Commercial Petroleum Ether Boiling Fractions and Physical Constants

Physical specifications, density ranges, refractive indices, and bench rotary evaporation parameters across commercial petroleum ether laboratory cuts, compiled from vendor reagent monographs (Sigma-Aldrich, Fisher Scientific), PubChem CID 23005, and rotary evaporator distillation guidelines.

Period covered: 2026. Coverage: Global.

Commercial Petroleum Ether Boiling Fractions and Physical Constants
Commercial CutInitial Boiling Point (°C)Final Boiling Point (°C)Nominal Density at 20 °C (g/cm³)Refractive Index n20/DPrimary Hydrocarbon ConstituentsRotovap Vacuum Setpoint (mbar)
30–40 °C Cut30400.6251.353iso-Pentane, n-pentane600
35–60 °C Cut35600.6481.356Pentane and isohexane isomers350
40–60 °C Cut40600.651.358n-Pentane, 2-methylbutane, 2-methylpentane280
60–80 °C Cut60800.671.370Hexane isomers, dimethylbutanes180
80–100 °C Cut801000.7051.385Heptane isomers, methylcyclohexane90
100–120 °C Cut (Ligroin)1001200.7351.400Octanes, nonanes, light alkylbenzenes40

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Petroleum Ether Boiling Point and Laboratory Solvent Properties

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →