Skip to main content
v2026.11,986 entries · CC-BY 4.0

pH Indicator Dye: How It Works and Common Dye Ranges

How pH indicator dyes change colour, how published transition ranges for the same dye differ, and what phenol red does in cell culture.

Written and maintained by CASRAI Editorial Board

Published

On this page

A pH indicator dye is a weak acid or base whose colour in solution depends on the pH, so the colour tells you roughly which side of a dye-specific transition range the solution sits on. Each dye changes colour over a window about two pH units wide (for example phenol red, yellow to red across roughly pH 6.8 to 8.2), which makes it a qualitative or semi-quantitative readout rather than a measurement to two decimals.

This page explains the colour-change mechanism, compares the published transition ranges of common dyes from two references (they differ by up to 0.4 pH units), and covers phenol red in cell culture media, where the same dye that reports pH also has documented biological effects.

What a pH indicator dye is

An indicator dye is a coloured compound that exists in two forms, a protonated acid form (written HInd) and a deprotonated form (Ind–), and the two forms have different colours. Which form dominates depends on the hydrogen-ion concentration of the solution. Because only a small amount of dye is added, it reports on the solution without noticeably changing its pH in a buffered system.

Indicator dyes appear in several lab settings. In titration the dye marks the endpoint (see the worked case in titration of a weak acid with a strong base). In cell culture a dye in the medium gives a visual cue that the medium is acidifying. In test papers, dyes are impregnated on paper so the same colour logic can be used without adding dye to the sample; see pH strips and their colour charts and nitrazine paper.

How the colour change works

The dye behaves as a weak acid: HInd + H2O ⇌ H3O+ + Ind–. Rearranged, pH = pKa + log([Ind–]/[HInd]). When the pH equals the dye’s pKa the two forms are present in equal amounts and the observed colour is a mix of both. The common textbook treatment (Harris, Exploring Chemical Analysis, as summarised in the general reference listed below) is that the eye sees a transition roughly between pKa minus 1 and pKa plus 1, which corresponds to a ratio of 10:1 on either side, a window about two pH units wide.

That rule is an approximation. Phenol red is a good test: Thermo Fisher describes it as a weak acid with a pKa of about 8.0, so the arithmetic of the rule would put the window near pH 7.0 to 9.0, while the pharmacopoeial table lists its transition as pH 6.8 to 8.2. The published window is the practical number to use, and the pKa-plus-or-minus-one rule is only a guide to where to look.

The same reference notes three practical consequences. The apparent range can shift slightly with the concentration of the indicator and with temperature. Indicators are usually destroyed at the extreme ends of the pH scale. And because the endpoint is judged by eye, the colour call is subjective; the gap between the true endpoint and the endpoint the dye shows is called the indicator error. A universal indicator, which blends several dyes, is described there as giving only a rough knowledge of pH.

Common indicator dyes and their transition ranges

The data table below this section compares the transition ranges of eight dye ranges as listed in two references: the USP 35-NF 30 table of indicators and test papers, and the general-reference table on the pH indicator page. Colour changes are those recorded in the USP table. The two references agree for some dyes and disagree for others.

Where the two references differ

  • Methyl orange: pH 3.2 to 4.4 in the USP table, 3.1 to 4.4 in the general reference.
  • Bromocresol green: 4.0 to 5.4 versus 3.8 to 5.4.
  • Methyl red: 4.2 to 6.2 versus 4.4 to 6.2.
  • Phenol red: 6.8 to 8.2 versus 6.4 to 8.0, the largest gap, up to 0.4 at either end.
  • Phenolphthalein: 8.0 to 10.0 versus 8.3 to 10.0.
  • Thymol blue: the acid-side range (1.2 to 2.8) matches, but the base-side range is 8.0 to 9.2 in the USP table and 8.0 to 9.6 in the general reference.
  • Bromothymol blue: 6.0 to 7.6 in both.

The practical lesson is that there is no single “the” range for a dye. Ranges depend on the reference, the dye concentration, the medium and the temperature. If a method or a pharmacopoeial monograph names a dye, use the range and indicator preparation that the method specifies, and do not substitute a range from a different table. Thymol blue also shows that one dye can have two transitions, one in the acid region and one in the base region.

Reading a colour change: what each range tells you

Choose the dye whose transition window brackets the pH you need to detect. A dye reports only whether the solution is below, inside or above its own window. Phenolphthalein, colourless to red across pH 8.0 to 10.0 in the USP table, says nothing useful at pH 5, while methyl orange (pink to yellow across 3.2 to 4.4) says nothing useful at pH 9. In titration, the dye is matched so that its transition falls on the steep part of the titration curve near the equivalence point; the related guide on weak acid and strong base titration shows why the endpoint pH matters.

Phenol red in cell culture medium

In biology labs the best-known indicator dye is phenol red, the red pigment in many cell culture media. According to a Thermo Fisher technical article on phenol red, it is yellow in acidic conditions (about pH 6.8 or lower), red at about pH 7.0 to 7.4 and pink in basic conditions (above about pH 8.2). A shift to yellow gives the user a clear visual cue that the medium may be depleted, and pink can signal a high pH environment. For the media types it appears in, see types of cell culture media.

Biological side effects of the dye itself

Phenol red is described in the literature as a standard pH indicator in cell and tissue culture media, and it is not biologically inert:

  • Estrogenic activity. Berthois, Katzenellenbogen and Katzenellenbogen (PNAS 1986) reported that phenol red has significant estrogenic activity at 15 to 45 micromolar. It bound the MCF-7 estrogen receptor with an affinity of about 0.001 percent that of estradiol, and at medium concentrations increased cell number to 200 percent and progesterone receptor content to 300 percent compared with phenol red-free medium. It had no effect on the estrogen receptor-negative line MDA-MB-231.
  • Redox activity. Morgan and colleagues (Chemico-Biological Interactions, 2019) reported phenol red at about 15 micromolar, undergoing oxidative halogenation by myeloperoxidase and depleting glutathione in HL-60 cells, with no considerable effect on HL-60 cell viability. Their conclusion was that phenol red does impart redox activity, which investigators should be wary of.
  • Assay interference. Thermo Fisher notes that hormone and receptor-sensitive assays are typically done in phenol red-free medium, and suggests media-only controls for absorbance or fluorescence assays, because the dye itself absorbs light.

The research-practice point is that the dye chosen to report pH can itself be a variable. In estrogen-receptor-positive lines such as MCF-7, or in redox-sensitive work, the choice between medium with and without phenol red belongs in the methods section, and the colour-based pH cue is traded for a pH meter reading or other monitoring. For what a meter reports compared with a colour, see what a pH meter is.

Indicator dye, pH paper or pH meter

All three report acidity in different forms. An indicator dye or test paper gives a colour class: which side of a transition window the sample falls on, read by eye against a chart or the solution’s own colour. A pH meter gives a numeric reading from an electrode. The colour readout is useful for quick screening, titration endpoints and in-vessel visual cues. It is less suited to work where a numeric value, a documented calibration or sub-unit resolution is needed. Because colour judgment is subjective and the range shifts with concentration and temperature, a dye reading is best treated as an approximate classification.

Where indicator dyes fall short

  • The reading is a judgment of colour, and different observers can call the endpoint differently.
  • The transition window is about two pH units wide, so the dye cannot resolve small differences inside the window.
  • The window depends on the reference table, the dye concentration and the temperature.
  • Indicators are usually destroyed at the extreme ends of the pH scale, so colour there is unreliable.
  • A coloured medium or coloured sample can mask the dye, and the dye can interfere with absorbance or fluorescence assays.
  • In cell culture the dye can have its own biological effects, as described above.

Common misunderstandings

  • “Each dye has one exact pH where it changes.” It changes gradually across a window; the pKa sits near its middle, and published window edges differ by reference.
  • “Phenol red is only a passive colour.” The sources above document estrogenic and redox effects.
  • “Any dye can be used for any titration.” The dye must change colour where the solution passes the equivalence point.
  • “A universal indicator gives an accurate number.” It gives rough knowledge of pH only.

Frequently asked questions

What is a pH indicator dye?

A pH indicator dye is a weak acid or base whose acid and base forms have different colours, so the solution colour shifts across a specific pH window. It is used to mark titration endpoints, to give a visual pH cue in culture medium and in test papers.

What pH range does phenol red cover?

The USP 35-NF 30 indicator table lists phenol red as yellow to red over pH 6.8 to 8.2. The general reference lists 6.4 to 8.0. Thermo Fisher describes yellow at about pH 6.8 or lower, red at about 7.0 to 7.4 and pink above about 8.2 in culture medium.

Why do published transition ranges for the same dye differ?

References differ by up to 0.4 pH units for dyes such as phenol red and bromocresol green. The apparent range can shift with indicator concentration and temperature, and judging a colour by eye is subjective.

Is phenol red harmful to cells?

The cited studies report effects rather than harm in general: estrogen-like activity in estrogen receptor-positive MCF-7 cells, and redox activity with glutathione depletion in HL-60 cells without a considerable effect on viability. Hormone-sensitive assays are typically run in phenol red-free medium.

Is an indicator dye as accurate as a pH meter?

No. A dye reports which side of its transition window a solution falls on, while a meter gives a numeric reading from an electrode. A dye is used where an approximate or qualitative answer is enough.

Sources

  • Thermo Fisher Scientific, The essential guide to phenol red in cell culture media (read 2026-11-15).
  • Berthois Y, Katzenellenbogen JA, Katzenellenbogen BS. Phenol red in tissue culture media is a weak estrogen. Proc Natl Acad Sci USA 1986;83(8):2496-2500, doi 10.1073/pnas.83.8.2496 (abstract read 2026-11-15).
  • Morgan et al. Chem Biol Interact 2019;310:108739, doi 10.1016/j.cbi.2019.108739 (abstract read 2026-11-15).
  • USP 35-NF 30, Indicators and Test Papers, indicator table, mirror (read 2026-11-15).
  • Wikipedia, pH indicator, citing Harris, Exploring Chemical Analysis, 3rd ed. (read 2026-11-15).

Data: Transition ranges of common pH indicator dyes in USP 35-NF 30 and a general reference

Side-by-side pH transition ranges for eight indicator dye ranges, compiled from the USP 35-NF 30 table of indicators and test papers (via a public mirror) and the pH indicator reference page. Differences show how published ranges vary by 0.1 to 0.4 pH units between references. Colour changes are those recorded in the USP table.

Transition ranges of common pH indicator dyes in USP 35-NF 30 and a general reference
Indicator dye (range)USP 35-NF 30 low (pH)USP 35-NF 30 high (pH)General reference low (pH)General reference high (pH)Colour change in USP table
Methyl orange3.24.43.14.4pink to yellow
Bromocresol green45.43.85.4not recorded in the compiled source
Methyl red4.26.24.46.2red to yellow
Bromothymol blue67.667.6yellow to blue
Phenol red6.88.26.48yellow to red
Phenolphthalein8108.310colorless to red
Thymol blue (acid range)1.22.81.22.8red to yellow
Thymol blue (base range)89.289.6yellow to blue

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about pH Indicator Dye: How It Works and Common Dye Ranges

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo