Skip to main content
v2026.11,986 entries · CC-BY 4.0

Microplate Plate Seals: Types, Materials and Compatibility

Lab microplate plate seals explained: closure types, heat-seal settings by plate polymer, and a six-seal compatibility table.

Written and maintained by CASRAI Editorial Board

Published

On this page

Microplate plate seals are the films, foils, mats and lids that close the wells of a multiwell laboratory plate so that samples do not evaporate, spill or cross-contaminate during PCR, ELISA, screening, culture or storage. The right seal depends on the plate material, the temperature range and how you will get the sample back out, because a film that is perfect for a thermal cycler may be wrong for long-term freezer storage. (The same phrase also names industrial gaskets; this page covers only the laboratory consumable.)

People who handle these plates every day are the main readers: researchers running PCR or immunoassays, core-facility and screening staff, and lab managers who stock consumables. This guide sets out the seal families, a manufacturer’s seal-by-seal table for one family of sealers, and the points the manufacturers themselves say matter. It sits alongside the guides to the microplate itself and to laboratory sealing film, which covers the stretchy paraffin-type film used on tubes and flasks rather than the plate seals described here.

What a microplate seal is and why plates need one

Alpha Laboratories describes microplates as standard in research and clinical diagnostic laboratories, and says plates need sealing to avoid contamination and evaporation. A seal is therefore a barrier between the wells and the room. In a few workflows the barrier is deliberately partial: cell and tissue culture plates need gas exchange, so the closure used there is a lid rather than an airtight film.

The applications that Alpha Laboratories lists for plate sealing are ELISA, PCR and real-time PCR, high-throughput screening, fluorescence and luminescence assays (where the seal affects the signal-to-noise ratio), and cell, tissue and bacterial culture. Its application categories also include HPLC, long-term storage, protein crystallography, short-term storage and incubation, and sonication. Different categories pull in different directions: optical clarity matters for a plate read through the seal, while a thermal cycler or a −80 °C freezer puts the weight on adhesion and temperature range.

How plate seals are built

Manufacturers describe a few constructions. A foil laminate is a layered material; Thermo Fisher describes its Thermo-Seal as a foil laminate that gives a very strong seal. Thin polymer films are the clear option: Thermo Fisher describes its Clear Seal products as thin polymer with good optical clarity. Aluminium foil seals with a pressure-sensitive adhesive are another form; a 2016 trade-press report on Alpha Laboratories’ AlumaSeal range says the AlumaSeal 96 and 384 consist of 38 μm aluminium foil with a 38 μm layer of acrylic adhesive, while AlumaSeal II is a 36 μm soft non-permeable aluminium foil with a 28 μm layer of medical-grade acrylic adhesive.

Adhesive films and foils are applied in two ways, according to Alpha Laboratories. For small numbers of plates they are pressed down by hand with a roller or paddle. In roll format they can be applied by sealers that use pressure without high temperature, which suits heat-sensitive samples and high throughput. Heat-sealing is a third route: Alpha Laboratories calls it the preferred method where an airtight, chemically resistant seal is wanted, because the seal forms without adhesives. Thermo Fisher’s ALPS 5000 is one example of a heat sealer, and its settings are covered below.

Types of plate closure and how they differ

Alpha Laboratories groups plate sealing systems into adhesive films and foils, sealing mats and plate lids. The table sets out what that source says about each, in order of increasing permanence.

Closure Permanence What the source says
Plate lid Temporary Useful when components are being added to the wells; easily removed.
Sealing mat Temporary, with evaporation protection Can be autoclaved and re-used.
Adhesive film or foil More permanent Applied to the plate; protects against evaporation, condensation, oxidation and cross-contamination during processing, storage and shipment.
Heat-sealed foil or film Permanent bond Airtight, chemically resistant seal formed without adhesives; described as the preferred method.

Pierceable, peelable and optically clear seals

Within foils and films, the useful distinction is how the seal comes off or gets opened. Thermo Fisher’s ALPS 5000 specification sheet describes some seals as easily pierced (Easy Pierce), others as difficult to pierce but peelable (Easy Peel), and a thin polymer pair as optically clear (Clear Seal and Clear Seal Diamond). The Alpha Laboratories AlumaSeal range is described in the trade report as readily pierced with automated or manual pipette tips, which it says avoids the aerosols and cross-contamination that can follow removal of other plate-sealing lids. The per-seal figures are in the data table below.

Heat-sealing settings by plate material

A heat sealer welds the seal to the plate rim, so the plate polymer matters. Thermo Fisher’s ALPS 5000 sheet gives a Plate Sealing Settings Guide for three common plate polymers.

Plate material Temperature setting Time setting
Polypropylene 150–175 °C 0.5–2.0 seconds
Polystyrene 145–165 °C 0.5–2.0 seconds
Polyethylene 150–170 °C 0.5–2.0 seconds

These are the settings guide for that instrument, not universal rules. The same sheet shows the instrument sealing from ambient temperature up to 199 °C, with a sealing time adjustable from 0.5 to 9.9 seconds and a typical cycle of about 30 seconds per plate. Alpha Laboratories makes the general point that compatibility between the microplate and the sealing process and materials is paramount, so a seal chosen without regard to the plate’s polymer can fail.

Sizes and specifications that matter

Microplates share a standardised footprint across manufacturers, defined by the ANSI/SLAS microplate standards, but plate heights, well counts and skirt types vary, and some manufacturers deviate from the height standard. That variation is why seals are sold for particular plate styles. The sourced dimensions available are these.

Item Stated specification Source
AlumaSeal 96 Sized to fit inside the rim of raised-rim PCR plates; partial-width end-tab for removal AlCircle, 17 Oct 2016
AlumaSeal 384 For any 384- or 96-well plate without a raised edge; single full-width end-tab AlCircle, 17 Oct 2016
AlumaSeal II Film measures 82.6 × 146.1 mm, stated to give sufficient sealing area for all PCR plates AlCircle, 17 Oct 2016
ALPS 5000 plate height range 8–46 mm Thermo Fisher specification sheet
ALPS 5000 foil length per plate 119–128 mm Thermo Fisher specification sheet

PCR plates also come in full-skirt, half-skirt (semi-skirted) and unskirted styles, and the skirt is analogous to the footprint and flange of standard plates; microplate lids can additionally depend on a corner notch, which the standards leave optional. A seal sized for a raised-rim plate is a different product from one for a plate with a flat top, as the AlumaSeal 96 and 384 entries show.

How to choose a seal: criteria the manufacturers state

Only criteria that appear in the sources are listed here; none is a ranking of products.

  • Match the seal to the plate polymer. Thermo Fisher lists the compatible plate materials (polypropylene, polystyrene, polyethylene, and for some seals cyclic olefin copolymer) against each seal, and Alpha Laboratories calls compatibility between plate, seal and sealing process paramount.
  • Match the temperature range. The seal-integrity ranges in the data table run from −200 °C to 120 °C depending on the product, and some seals reach 120 °C only with the pressure of a cycler lid.
  • Check thermal cycler lid compatibility. Several of the Thermo Fisher seals are listed as suitable for PCR only with a screw-down heated lid, or a screw-down or clip-down heated lid.
  • Decide how samples will be retrieved. Pierceable foils suit access by pipette tip; peelable seals suit removal and, for Easy Peel, resealing several times.
  • Consider the readout. Alpha Laboratories notes that for fluorescence and luminescence the seal affects signal-to-noise; Thermo Fisher lists its clear polymer seals for fluorescence and colorimetric applications.
  • Consider the solvent. Some seals are listed as recommended for use with DMSO, while the Easy Peel seal is listed as suitable for DMSO only below 4 °C. For DMSO’s own properties see the DMSO reference.
  • Consider the method of application. Hand application with a roller or paddle suits small numbers; roll-format sealers using pressure suit heat-sensitive samples; heat sealers give the airtight, adhesive-free seal.

Seals for PCR, ELISA and storage

For PCR, the seal sits above the wells inside a thermal cycler. The Thermo Fisher sheet therefore gives an explicit PCR note per seal: Thermo-Seal is described for PCR including use in waterbath cyclers, while Easy Peel is limited to screw-down heated-lid cyclers.

For immunoassays, Alpha Laboratories lists ELISA among the applications, and groups short-term storage, incubation and ELISA together as one application category. For an overview of the assay workflow that uses these plates, see the ELISA protocol basics guide. For long-term storage the same sheet points to foil laminates and low-temperature ranges: Thermo-Seal is described for long-term storage including at low temperatures and for transport, and Easy Peel for long-term storage at low temperatures.

Safe use and handling basics

Manufacturer documents on seals concentrate on process settings rather than hazards, so the general points are drawn from them. Apply the seal as the supplier’s instructions describe, using the settings stated for that plate material; keep to the seal’s stated temperature range; and treat pierced seals as no longer sealed, because the wells are open once pierced. Alpha Laboratories notes that foil seals pierced by pipette tip avoid the aerosol that removing a lid can cause, which is a reason to open only the wells that are needed. Heat sealers operate at up to 199 °C on the ALPS 5000 sheet, so manufacturers’ instrument manuals govern safe operation of the hot sealing plate.

Common mistakes

  • Applying a heat-seal foil to a plate of a polymer the foil is not listed for; the Thermo Fisher table lists compatible plate materials per seal for this reason.
  • Using a seal rated to 80 °C inside a thermal cycler without checking the note that it reaches 120 °C only under cycler lid pressure.
  • Choosing a peelable seal for transport or long-term storage when a stronger foil laminate is described for that use, or the reverse for repeated access.
  • Using a thick or opaque seal on a plate read optically, when a clear polymer seal is listed for fluorescence and colorimetric work.
  • Treating a sealing mat or lid as an airtight seal: Alpha Laboratories describes lids and mats as temporary closures.
  • Assuming a seal’s published range applies to any sealer. The Thermo Fisher integrity ranges and compatibility are stated for its ALPS sealers, and other instruments need their own settings.

The data table below compares six Thermo Fisher heat-seal foils and films from the ALPS 5000 specification sheet: material, compatible plates, sealing conditions, seal integrity range and applications.

Sources

Data: Thermo Fisher ALPS 5000 heat-seal foils and films: compatibility and conditions

Six heat-seal foils and films listed on the Thermo Fisher ALPS 5000 specification sheet (ALPS 5000 - 0320), compiled into one table of material, compatible plate polymers (PP polypropylene, PE polyethylene, PS polystyrene, COC cyclic olefin copolymer), sealing time and temperature, seal integrity range and applications. Ranges are Thermo Fisher's for ALPS sealers.

Thermo Fisher ALPS 5000 heat-seal foils and films: compatibility and conditions
Seal (Thermo Fisher catalogue no.)Material and handlingCompatible plate materialsSealing time and temperatureSeal integrity rangeApplications
Thermo-Seal AB-3559Foil laminate; very strong; pierceable with a single tip or Pierce Plate; good solvent resistance; DMSO recommendedPP1.5–2.5 s at 165–175 °C−80 to 120 °CLong-term storage including low temperature, transport, PCR including waterbath cyclers
Easy Pierce AB-3738Foil; easily pierced; peelable by hand; second seal can go over it; DMSO recommendedPP, PE0.5–3.0 s at 165–175 °C−80 to 80 °C; up to 120 °C with cycler lid pressure384-well formats where piercing is useful; PCR with screw-down lid
Easy Pierce 20 μm AB-3720Thin foil; easily pierced; peelable by hand; good solvent resistance; DMSO recommendedPP, PE0.5–2.0 s at 165–175 °C−80 to 80 °C; up to 120 °C with cycler lid pressure384-well formats where piercing is useful; PCR with screw-down lid
Easy Peel AB-3739Foil laminate; difficult to pierce; peelable; can be removed and resealed several times; DMSO only below 4 °CPP, PE, COC1.5–2.5 s at 165–170 °C−200 to 90 °C; up to 120 °C with cycler pressureLong-term low-temperature storage; PCR with screw-down heated lid only
Clear Seal AB-3797Thin polymer; pierceable; good optical clarity; some solvent resistancePP, PS, PE1.5 s at 170 °C−80 to 80 °C; up to 120 °C with cycler pressureFluorescence and colorimetric; PCR with screw-down or clip-down heated lid only
Clear Seal Diamond AB-3799Thin polymer; peelable; good optical clarity; some solvent resistancePP, PS, PE, COC1.5–3.0 s at 170 °C−80 to 120 °CFluorescence and colorimetric; PCR with screw-down or clip-down heated lid

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Microplate Plate Seals: Types, Materials and Compatibility

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →