Potts Scissors: Angles, Sizes and FDA Class

Potts scissors are angled vascular scissors. Real FDA UDI listings show 25 to 125 degree angles, lengths and Class I status under 21 CFR 878.4800.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Potts scissors are hand-held surgical scissors with blades set at an angle to the handle, used in open vascular surgery. This page describes products and general use; it is not medical advice.

Who uses them: surgeons and operating-room and sterile-processing staff, and anyone who has to read an instrument listing correctly. After this page you should be able to decode a Potts scissors listing (angle, length, tip, regulatory class) and tell it apart from the other instruments that carry the same name.

What are Potts scissors?

Potts scissors, also written Potts-Smith, are angled vascular scissors: two small pivoted blades that cut with a shearing action, with the blades bent away from the line of the handle so they can reach a vessel wall. The Global Medical Device Nomenclature (GMDN) term “Vascular scissors” (code 44354), as recorded in FDA’s UDI database, defines the class as a hand-held, manual instrument designed to cut a blood vessel, either across it or lengthwise to open it, during open vascular surgery, and not intended for endoscopic use. The same entry notes the blades are often pointed, may be straight, curved sideways or acutely angled, and may include carbide inserts along the cutting edges (checked 2026-10-30).

The International Committee of the Red Cross item catalogue describes its Potts-Smith vascular scissors as used in “the fine dissection of vessels in vascular surgery” and adds “Do not use for any other purpose” (checked 2026-10-30; the catalogue is marked as no longer updated).

How are they built?

The ICRC catalogue entry for its 19 cm, 60 degree model lists martensitic steel, with blades angled on the right side and blunt-tipped. The GMDN definition above adds that vascular scissors can carry carbide inserts along the cutting edges, which is why listings may say “TC” (tungsten carbide). For background on the material, see tungsten carbide. FDA UDI records for the scissors in the table below show them as reusable, with sterilization required before use, and list moist heat or steam sterilization as the labelled method.

Types and variants: what real listings show

There is no single Potts pattern. The table lists real device records from FDA’s openFDA UDI database (device description as the manufacturer registered it, checked 2026-10-30). It is a sample of registered listings, not a complete catalogue.

Listing name Angle Length Tip / blade note Manufacturer
Potts-Smith Vascular Scissors 60 degrees 6 7/8 in (175 mm) sharp/sharp Aesculap AG
Potts-Smith Vascular Scissors 25 degrees 11 in not stated HNM Stainless
Potts-Smith Vasc Sci 45 degrees 7 1/2 in standard Boss Instruments
Potts-Smith scissors 45 degrees 7 1/2 in blunt tip HNM Stainless
Super-Cut Potts-Smith Vascular Scissors 45 degrees 190 mm (7 1/2 in) Super-Cut RZ-Medizintechnik
CERAMO TC Potts vessel scissors 45 degrees 230 mm TC (carbide) Fehling Instruments
DeBakey Potts-Smith scissors 60 degrees 9 in (23.0 cm) rounded tips Novo Surgical
DeBakey Potts-Smith scissors, TC inserts 45 degrees 7 in (17.5 cm) rounded tips Peak Medical Distribution
Diethrich-Potts scissors 45 degrees 7 in (18.0 cm) micro fine blades Novo Surgical
Vascular Potts scissors, 3.5 mm shaft 125 degrees working length 170 mm single action RZ-Medizintechnik
Miami Instrument Potts scissors, heavy pattern 45 degrees 35 cm sharp Vitalitec International

Two readings follow from the table. First, the same family name appears with 25, 45, 60 and 125 degree angles, so the name alone does not identify the angle. Second, the added surname (DeBakey, Diethrich, Lillehei) marks a manufacturer’s pattern variant; the records give the angle and length but not a standard that defines what each surname means, so check the item description rather than assume.

Sizes and specifications that matter

In the registered listings the specifications that distinguish one Potts scissors from another are the blade angle, overall length (about 6 7/8 in to 11 in in the sample, with a 35 cm heavy pattern as the long end), the tip (sharp or blunt/rounded), the blade edge (plain, Super-Cut, micro-fine) and whether the blades have carbide inserts. The Medecins Sans Frontieres Unicat catalogue lists the same instrument as separate items by angle: 25 degrees (55-15-42), 45 degrees at 19 cm (55-15-44) and 60 degrees (55-15-46), each classified “Vascular scissors, reusable” (checked 2026-10-30).

How to read a listing

Read, in order: the full item description (not just the name), the angle in degrees, the length and tip, and the stated reuse and sterilization status. FDA UDI records state whether a device is single-use and whether sterilization is required before use; the vascular scissors listed in the table above are all recorded as reusable.

Regulatory class in the United States

Most Potts scissors in the sample are registered under FDA product code LRW, “Scissors, General, Surgical”, which openFDA lists as Class 1 under 21 CFR 878.4800 (general surgical manual instruments). That regulation covers nonpowered, hand-held or hand-manipulated devices, reusable or disposable, intended for various general surgical procedures; Class I devices are subject to general controls and exempt from premarket notification under 21 CFR 807 Subpart E, subject to the limitations in 21 CFR 878.9 (Cornell LII, checked 2026-10-30). Not every record uses LRW: several Potts-named scissors in the same database carry other product codes, so the code printed on a given label is the one to rely on.

Safe use and handling basics

The GMDN definition describes the device as reusable and intended to be sterilized prior to use, and the Aesculap record is described as non-sterile and reusable. The practical consequence is general: the item is reprocessed according to the manufacturer’s instructions for use, and those instructions, not this page, define the method. The ICRC catalogue’s instruction to use the scissors for fine vessel dissection only and “not for any other purpose” is also worth keeping in instrument-handling rules. This page gives no operating technique.

Common mistakes

  • Assuming “Potts” means one pattern. The listings show 25, 45, 60 and 125 degree versions, plus straight and curved patterns (see below).
  • Confusing vascular Potts-Smith scissors with Potts tenotomy or Potts-Smith dissecting scissors. The same database lists “Potts Tenotomy, Straight, 8 in” (Aspen Surgical) and “Potts-Smith Dissecting, Curved, 5 1/2 in” (Aspen Surgical, also Ambler Surgical at 7 1/2 in): straight or curved patterns, not the angled vascular type. For those families see surgical scissors types, dissecting scissors and Stevens tenotomy scissors.
  • Confusing scissors with forceps. The Potts-Smith name also appears on tissue and dressing forceps in the same records. A listing that says forceps or “1 x 2 teeth” is not scissors.
  • Mixing up general-purpose scissors patterns. For how other named pairs differ, see Metzenbaum vs Mayo scissors and Kelly scissors.

FAQ

What are Potts scissors used for?

Fine cutting of blood vessels in open vascular surgery. That is the use stated in the GMDN vascular scissors definition and in the ICRC catalogue entry (both checked 2026-10-30).

What angle are Potts scissors?

It varies by pattern. The listings in the table show 25, 45, 60 and 125 degrees; 45 degrees is the most frequent in that sample.

Are Potts scissors reusable?

The vascular scissors in the table are recorded as reusable and as requiring sterilization prior to use. One Novo Surgical Potts-Smith dissecting record is marked single-use, which shows why the full listing must be read.

Sources

All sources checked 2026-10-30.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Potts Scissors: Angles, Sizes and FDA Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →