Short answer
PriMatrix is an acellular dermal repair scaffold derived from fetal bovine dermis, designed to support cellular repopulation and revascularization in chronic and surgical wounds. Cleared by the FDA under 510(k) premarket notifications K061407 and K153690 (product code KGN), it is enriched in embryonic Type III collagen and billed under CMS HCPCS code Q4110 per square centimeter.
Definition and scope
PriMatrix is a sterile, bioabsorbable extracellular matrix (ECM) scaffold manufactured by Integra LifeSciences (originally developed by TEI Biosciences). It is registered under Global Medical Device Nomenclature (GMDN) code 45023 as an animal-derived wound matrix dressing. The matrix is derived exclusively from fetal bovine dermal tissue, providing a natural structural scaffold without artificial chemical cross-linking agents.
In regulatory terms, the United States Food and Drug Administration (FDA) regulates PriMatrix as an Unclassified preamendment medical device under the General and Plastic Surgery panel. Its regulatory standing is established through 510(k) clearances, including K061407 (June 29, 2006) and K153690 (February 22, 2016), under product code KGN (“Dressing, Wound, Collagen” / “Wound Dressing With Animal-Derived Material(S)”). An antimicrobial formulation incorporating ionic silver, PriMatrix Ag, holds clearance under K100261 under product code FRO. Under 21 CFR Part 801 Subpart D, PriMatrix is restricted to prescription use (Rx only) by licensed healthcare practitioners.
The clinical scope of PriMatrix encompasses partial-thickness and full-thickness wounds across acute and chronic presentations. Sourced from FDA-cleared indications, the device is intended for:
- Diabetic foot ulcers and neuropathic ulcers
- Venous stasis ulcers and mixed arterial-venous lesions
- Pressure ulcers (Stage 3 and Stage 4 pressure injuries)
- Second-degree burns (partial-thickness thermal wounds)
- Surgical wounds, including post-Mohs micrographic surgery defects, podiatric excisions, donor graft sites, post-laser surgery wounds, and wound dehiscence
- Trauma wounds, including abrasions, lacerations, and skin tears
- Tunneled, undermined, and draining wounds
Healthcare facilities managing surgical wound complications can consult surgical wound classification principles to evaluate contamination categories and infection risk factors.
How it works or how it is used in practice
PriMatrix functions as an acellular structural scaffold that mimics native dermal architecture. Because it is sourced from fetal bovine dermis, it possesses an elevated ratio of embryonic Type III collagen alongside Type I collagen. Type III collagen is the primary collagen type produced during early fetal and wound repair phases, facilitating cellular attachment, capillary budding, and dermal fibroblast migration without triggering hyper-inflammatory cross-linked foreign-body reactions.
When placed in contact with viable wound tissue, the scaffold absorbs endogenous blood and interstitial fluid. This promotes the deposition of a fibrin network within its collagen channels, binding endogenous growth factors (such as vascular endothelial growth factor and basic fibroblast growth factor). Host cells progressively populate the matrix, remodeling the scaffold into organized host tissue over several weeks.
In clinical practice, PriMatrix serves as an advanced dermal template applied to thoroughly debrided wound beds. Clinicians secure the scaffold using surgical sutures, staples, or bolster dressings to maintain continuous, intimate contact with viable vascularized tissue. It is managed under secondary dressings, such as a silicone foam wound dressing to regulate exudate, or in tandem with negative pressure wound therapy as outlined in what is a wound vac.
Types or related concepts
PriMatrix is manufactured in multiple configurations tailored to different anatomical geometries and exudate levels. Clinicians and procurement teams evaluate these alongside broader categories covered in our overview of types of collagen dressing.
| Configuration | Physical Architecture | Clinical Setting | Exudate and Drainage Handling | Key Differentiator |
|---|---|---|---|---|
| PriMatrix Standard Solid Sheet | Continuous uniform acellular collagen membrane (0.20 mm to 1.04 mm thickness) | Flat partial- and full-thickness wounds, clean surgical excisions, donor sites | Suited for low to moderate exudate; unperforated sheet retains fluid if drainage surges | Provides maximum uniform dermal matrix coverage |
| PriMatrix Fenestrated | Sheet featuring pre-cut linear perforations and slits | Moderate-exudate ulcers, diabetic foot ulcers, irregular wound bases | Slits allow exudate to pass through into secondary dressings without lifting graft | Prevents fluid pooling under the matrix without requiring manual cutting |
| PriMatrix Meshed | Expanded geometric mesh lattice pattern | Extensive defects, irregular contours, high-drainage surgical wounds | High permeability for heavy exudate drainage; ideal with negative pressure therapy | Conforms over undulating anatomical margins and covers expanded surface areas |
| PriMatrix Ag Antimicrobial | Fetal bovine collagen matrix bonded with ionic silver (FDA K100261) | Wounds colonized with bacteria or presenting elevated localized infection risk | Ionic silver provides broad antimicrobial activity across the scaffold surface | Cleared under FDA product code FRO; detailed in what is a collagen silver dressing |
Where it matters for labs, clinics or supply decisions
PriMatrix represents an essential inventory category for wound care centers, hospital surgical suites, and tissue-engineering research teams. Procurement and clinical supply coordinators should manage acquisition through a four-point verification framework:
- Reimbursement and HCPCS Coding: Unlike standard collagen dressings billed under HCPCS A-codes (A6021–A6024), PriMatrix is classified by the Centers for Medicare and Medicaid Services (CMS) as a Cellular and Tissue-Based Product (CTP). It is billed under HCPCS Level II code Q4110 (“Primatrix, per square centimeter (add-on, list separately in addition to primary procedure)”). Reimbursement units correspond directly to the area in square centimeters (cm²) applied, requiring precise defect measurement to avoid wasted units.
- Storage and Temperature Stability: Sourced from FDA AccessGUDID registry data and manufacturer specifications, PriMatrix is stable at controlled room temperature between 15°C and 30°C (59°F and 86°F). It eliminates the need for expensive -80°C freezers or monitored cold-chain refrigeration required by cellular allografts.
- Rehydration and Handling Parameters: Manufacturer instructions specify that the dry scaffold must be rehydrated in sterile room-temperature 0.9% sodium chloride saline before placement. Warm saline is strictly contraindicated because thermal exposure denatures collagen triple-helix fibrils. The scaffold must be discarded if shrinkage occurs during hydration.
- Supplier Vetting: Single-use sterile packaging integrity and verifiable GS1 lot traceability are paramount. Supply teams can consult vetting standards in wound care suppliers to audit vendor compliance and regulatory authenticity.
Common misunderstandings
Common clinical and supply chain misconceptions regarding PriMatrix include:
- Assuming PriMatrix is derived from adult bovine cattle: Adult bovine dressings primarily feature mature Type I collagen with extensive intermolecular cross-links. PriMatrix is sourced exclusively from fetal bovine dermis, yielding a scaffold naturally rich in Type III embryonic collagen with higher compliance.
- Believing refrigeration or freezing is necessary: Unlike living cellular allografts, PriMatrix is an acellular lyophilized scaffold that requires only room-temperature shelf storage (15°C to 30°C).
- Billing under general wound care dressing codes: Submitting PriMatrix claims under generic collagen codes (A6021 or A6022) results in claim rejection. PriMatrix must be billed under CMS code Q4110 per square centimeter.
- Rehydrating with heated saline or chemical cleansers: Soaking PriMatrix in warmed saline or chemical antiseptics compromises collagen structural integrity. Only sterile room-temperature 0.9% saline is acceptable.
- Applying PriMatrix on third-degree burns: While indicated for second-degree burns, FDA 510(k) clearances and manufacturer labeling explicitly contraindicate PriMatrix for third-degree (full-thickness) burns.
Frequently asked questions
What is PriMatrix made of?
PriMatrix is derived from acellular fetal bovine dermis. It consists of an uncrosslinked extracellular matrix scaffold enriched in Type I and embryonic Type III collagen, processed to remove non-collagenous cellular elements, lipids, and carbohydrates.
What is the CMS HCPCS billing code for PriMatrix?
PriMatrix is billed under CMS HCPCS Level II code Q4110 (“Primatrix, per square centimeter”). Billing units reflect the surface area in square centimeters (cm²) placed onto the prepared wound bed.
Does PriMatrix require cold-chain storage or refrigeration?
No. PriMatrix is stored at controlled room temperature between 15°C and 30°C (59°F and 86°F). It does not require refrigeration or frozen storage.
What are the primary contraindications for PriMatrix?
PriMatrix is contraindicated in patients with known hypersensitivity to bovine products or collagen, and it is contraindicated for use on third-degree burns.
Sources
- U.S. Food and Drug Administration. 510(k) Premarket Notification K061407: PriMatrix Dermal Repair Scaffold. Cleared June 29, 2006. Available from: https://www.accessdata.fda.gov/cdrh_docs/pdf6/K061407.pdf (Accessed November 11, 2026).
- U.S. Food and Drug Administration. 510(k) Premarket Notification K153690: PriMatrix Dermal Repair Scaffold Labeling Modification. Cleared February 22, 2016. Available from: https://www.accessdata.fda.gov/cdrh_docs/pdf15/K153690.pdf (Accessed November 11, 2026).
- U.S. Food and Drug Administration. AccessGUDID Unique Device Identification Database: PriMatrix Dermal Repair Scaffold (GMDN 45023, DI 10381780113331). Available from: https://accessdata.fda.gov (Accessed November 11, 2026).
- Centers for Medicare and Medicaid Services (CMS). Healthcare Common Procedure Coding System (HCPCS) Level II Code Q4110. Available from: https://www.cms.gov/medicare/coding-billing/healthcare-common-procedure-system (Accessed November 11, 2026).
- Integra LifeSciences. PriMatrix Dermal Repair Scaffold Instructions for Use (IFU). Available from: https://www.integralife.com (Accessed November 11, 2026).