PRO-CTCAE: What It Is, the 124 Items and NCI Terms of Use

PRO-CTCAE is NCI’s patient-reported symptom system: 78 symptoms, 124 items, a 7-day recall, validation results and its terms of use.

Written and maintained by CASRAI Editorial Board

Published

On this page

PRO-CTCAE (Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events) is a measurement system from the US National Cancer Institute that lets patients report the symptomatic adverse events they experience in cancer clinical trials. It covers 78 symptoms through a library of 124 items, each asking about the past 7 days, and it is designed to be used alongside the clinician-graded CTCAE.

Short answer

The instrument exists because investigator reporting through CTCAE tends to underdetect symptomatic adverse events (Basch et al., 2014). NCI therefore built a companion system in which patients answer plain-language questions about how often a symptom occurred, how severe it was, how much it interfered with usual activities, whether it was present, or how much of it there was. The questions are free to use, but under NCI terms they may not be modified, translated or redistributed without NCI’s written consent.

Definition and scope

NCI’s Healthcare Delivery Research Program describes PRO-CTCAE as a patient-reported outcome measurement system developed to evaluate symptomatic toxicity in patients on cancer clinical trials. The program page states that it covers adults, children and adolescents, that it is available in more than 60 validated languages, and that a pediatric module, Ped-PRO-CTCAE, exists. It also lists an Instruments and Form Builder and release notes as resources on the same site.

The scope is deliberately narrow. The terms of use say PRO-CTCAE was developed to be used in conjunction with CTCAE in clinical research, including pragmatic and implementation trials and collection through electronic health records. Its purpose is to describe, in aggregate, the safety and tolerability of a compound, regimen or device. It is not for diagnostic, prognostic or therapeutic purposes, and not for assessing efficacy. Reports come from the patient by self-report; for children who cannot self-report, the terms allow caregiver report.

It is a companion to the clinician-graded Common Terminology Criteria for Adverse Events (CTCAE), not a replacement for it. For how the clinician-side grading scheme itself has changed, see the guide to CTCAE version 6.

Why NCI built it

Basch and colleagues, writing in the Journal of the National Cancer Institute in 2014, summarised the rationale: adverse event reporting by investigators in trials has been shown to underdetect symptomatic events, and NCI issued two contracts to develop a companion patient-reported system. The team began with the 790 adverse event terms in CTCAE and identified 78 as appropriate for patient self-report. Each of the 78 received a plain-language term and one to three items asking about frequency, severity and/or interference, giving a library of 124 items. The development work included cognitive interviewing, web and interactive voice response (IVR) software, and ongoing translation.

The 78 symptomatic terms are therefore a small share of the whole criteria set, which is consistent with PRO-CTCAE being a complement to CTCAE. Dueck and colleagues (JAMA Oncology, 2015) put it at roughly 10 percent of the 790 adverse events.

How it is used in practice

The item structure

Every PRO-CTCAE item pairs a plain-language symptom name with one attribute and the standard recall period of “the past 7 days”. Dueck et al. report the five attribute formats and the number of symptomatic terms using each: frequency (25), severity (51), interference with usual or daily activities (25), presence/absence (21) and amount (2). Because a symptom can have more than one attribute, these counts add up to the 124 items rather than to 78. The data table below sets out the formats, their response options and one example symptom for each.

Administration modes

The validation study delivered items to patients on tablet computers through the PRO-CTCAE web platform hosted at NCI, with an IVR telephone option also developed. The software uses conditional branching: when a symptom has more than one attribute, follow-up questions about severity or interference are skipped if the respondent says the symptom did not occur. The software is compliant with Section 508 of the US Rehabilitation Act. In the validation study, no more than 58 symptoms (82 items) were presented to any participant, to limit burden.

PRO-CTCAE, CTCAE and other patient-reported measures

The three tools below are often discussed together, and they answer different questions.

Feature CTCAE PRO-CTCAE
Who reports Clinician or investigator grading Patient self-report (caregiver report for children who cannot self-report)
Adverse event terms covered 790 AE terms 78 symptomatic AE terms
Unit of measurement A grade per adverse event 124 items on frequency, severity, interference, presence or amount
Recall period Set by the trial’s assessment schedule The past 7 days
Intended use Grading adverse events in trials Describing aggregate safety and tolerability alongside CTCAE; not efficacy, diagnosis or treatment decisions

Row sources: Dueck et al. 2015 for the term counts and recall period; NCI terms of use for who reports and intended use. The CTCAE column describes the clinician-graded system as the PRO-CTCAE papers do, not any single version of it.

More generally, PRO-CTCAE is one kind of patient-reported outcome measure. The guide to patient-reported outcome measures (PROMs) places such instruments in the wider field, and the dictionary entry on electronic patient-reported outcomes (ePRO) covers the electronic collection side. When a trial protocol or its report must describe patient-reported data, CONSORT-PRO and SPIRIT-PRO set out the reporting expectations.

Evidence behind the instrument

The principal validation study (Dueck et al., 2015) enrolled 975 participants between January 2011 and February 2012 across nine US centres, with 940 analysed. Participants were English-speaking adults receiving outpatient chemotherapy or radiotherapy. The results, as reported:

  • Construct validity: 119 of the 124 items met at least one validity criterion, using anchors such as the EORTC QLQ-C30, ECOG performance status and a patient global impression of change.
  • Reliability: 36 of the 49 items tested for test-retest reliability reached an intraclass correlation of at least 0.7, with a median of 0.76.
  • Responsiveness: 27 items were assessed, with a median correlation of 0.43.

The authors are explicit about limits. The study was English-language and US-only, test-retest reliability was examined for 49 of the 124 items, and five items failed to show validity. Those five belong to four adverse events: nosebleeds, injection-site pain, swelling or redness, pain during vaginal sex, and rash. The validation numbers above apply to that English-language study.

Where it matters for research offices and trial teams

Terms of use as a checklist

NCI’s PRO-CTCAE terms of use are the part that research offices and sponsors most often need to get right. Drawn directly from the terms:

  • The instrument is described as freely available for all to use.
  • NCI holds all rights, including rights in translations.
  • A recipient may not adapt, alter, abridge, modify, translate or redistribute the items without NCI’s written consent. Selecting a subset is a design question to settle against the terms and the Instruments and Form Builder, not to assume.
  • Registered studies may share items with regulators and journals.
  • Publications must state that permission was obtained by registering the study and agreeing to the terms, and must cite the PRO-CTCAE website.
  • Use is limited to the purposes above: aggregate safety and tolerability, not diagnosis, prognosis, therapy or efficacy.

Data standards

NCI states that it finalized PRO-CTCAE data standards together with CDISC and the US Food and Drug Administration. For data managers this means the collected responses have a defined standard representation, which is the reason to read the program page before designing case report forms rather than inventing field names locally.

Common misunderstandings

PRO-CTCAE is not a replacement for CTCAE

It was built to run in conjunction with CTCAE. It covers 78 of 790 adverse event terms and produces no clinician grade.

It is not an efficacy or clinical decision tool

The terms of use exclude efficacy assessment and diagnostic, prognostic or therapeutic use. It describes tolerability across a group of participants.

Free does not mean freely editable

The items are free to use, yet shortening, rewording or translating them needs NCI’s written consent. A locally translated version made without that consent falls outside the terms.

It is not a single questionnaire with one score

The system is an item library from which trials choose symptoms. Responses are item-level frequency, severity, interference, presence or amount answers, as the data table below shows.

Validation does not cover every item or language

The published validation tested items in English among US cancer patients, and some items were not tested for reliability or did not validate.

This page is general research-practice information, not medical advice.

Sources

Data: PRO-CTCAE item formats: attribute, response options and example symptom

The five attribute formats of the PRO-CTCAE item library, with the number of symptomatic adverse event terms using each, the response options shown to patients, and one example symptom per format. Compiled from Table 1 of the published validation study, which uses a recall period of the past 7 days.

Period covered: 2011/2015.

PRO-CTCAE item formats: attribute, response options and example symptom
AttributeSymptomatic AE terms using it (terms)Response optionsExample symptom
Frequency25Never / Rarely / Occasionally / Frequently / Almost constantlyVomiting
Severity (at its worst)51None / Mild / Moderate / Severe / Very severePain
Interference with usual or daily activities25Not at all / A little bit / Somewhat / Quite a bit / Very muchSudden urges to urinate
Presence21No / YesUnusual darkening of the skin
Amount2Not at all / A little bit / Somewhat / Quite a bit / Very muchHair loss

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about PRO-CTCAE: What It Is, the 124 Items and NCI Terms of Use

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →