Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General information, not medical advice. This page explains how public access defibrillation programs are described by public-health and federal sources; it does not give emergency or clinical instructions.
Short answer
Public access defibrillation (PAD) is a program approach that puts automated external defibrillators (AEDs) where lay bystanders and nonmedical first responders can reach them, backed by training, device maintenance, emergency-services coordination, quality review and liability protection. In the CDC’s 2010 review of US laws, no jurisdiction required all 13 program elements the review tracked.
Definition and scope
The CDC’s review of PAD laws notes that the American Heart Association promotes structured PAD programs so that nonmedical first responders and lay bystanders can use AEDs, and that PAD policies increase the public availability of these devices. The 2001 HHS and GSA guidelines for federal facilities use the term in a narrower, practical sense: “public access” refers to the accessibility of the device itself, and the guidelines offer a general framework for initiating a design process for a program.
So a PAD program is more than owning an AED. The device is one component of a set of arrangements that decide whether it is findable, working and usable when needed. This page is about the program concept; for the device itself see what a defibrillator is.
Public access defibrillator vs PAD program
“Public access defibrillator” is commonly used for the device placed in a public location; “public access defibrillation” names the practice and program around it. This page uses PAD for the program. It is unrelated to open-access publishing policies that use similar wording, such as the NIH public access policy for journal articles.
How a PAD program is described in practice
The CDC review groups program features into six categories, comprising 13 elements in total (Gilchrist et al., Preventing Chronic Disease 2012;9:110196, covering laws in force in 2010):
- Targeted AED site placement to maximize use.
- Ongoing basic life support (CPR) and AED training of anticipated rescuers.
- Maintenance and testing of the AED.
- Coordination with emergency medical services (EMS) and a medical provider.
- Continuous quality improvement.
- Limited liability for AED users and others.
The 2001 federal-facility guidelines (HHS Office of Public Health and Science and GSA Office of Governmentwide Policy, published in the Federal Register on 23 May 2001) describe a related set of design elements for federal buildings: medical direction and oversight; training, certifying and retraining personnel in CPR and AED use; placement and access; maintenance of the AED and support equipment; and integration with facility security and EMS systems. They recommend that devices be easy to reach, secured, well marked and near a telephone, and that formal refresher training be conducted at least every two years. These are federal-facility guidelines from 2001, not a general legal standard.
Types and related concepts: how the two frameworks compare
| Program feature | CDC six-category review (2012) | Federal-facility guidelines (2001) |
|---|---|---|
| Placement of AEDs | Yes (1 element) | Yes, easy to reach, secured, well marked, near a telephone |
| Training of rescuers | Yes (1 element) | Yes, refresher at least every two years recommended |
| Device maintenance | Yes (1 element) | Yes, regularly and after each use |
| EMS and medical coordination | Yes (4 elements) | Medical direction and oversight; integration with EMS systems |
| Continuous quality improvement | Yes (2 elements) | Yes (quality assurance and data/information management plans) |
| Liability protection (Good Samaritan) | Yes (4 elements) | Understanding legal aspects is an element; Good Samaritan protection is not named in the element list |
The comparison shows where the frameworks differ: the CDC and AHA framing treats quality improvement and liability protection as program elements, while the federal guidance covers quality assurance and legal aspects but does not name Good Samaritan protection.
Where it matters for labs, clinics and supply decisions
The CDC review found that requirements are uneven across US jurisdictions as of its 2010 data:
| Finding (2010 laws) | Share of jurisdictions |
|---|---|
| Provide some immunity to AED users | All |
| Require AED maintenance | 60% |
| Require EMS notification or registration | 59% |
| Impose training requirements | 55% |
| Require medical oversight | 41% |
| Require at least 10 of the 13 elements | 18% |
| Require 3 or fewer elements | 31% |
Few jurisdictions required a continuous quality improvement process. Because laws change, a facility’s obligations depend on its current state and local rules; these figures describe the legal landscape in the 2010 review and are not a statement of present law. For the registration, expiry, training and post-use reporting side of running a program, see AED program management. For device selection, see the AED facility selection guide, and for one setting, gym and fitness center AED requirements. Wayfinding signage is covered in AED symbols.
Common misunderstandings
- “Having an AED means having a PAD program.” The sources treat placement as one element among training, maintenance, EMS coordination, quality review and liability protection.
- “Public access means anyone on the premises may use it.” The federal guidelines state that “public access” concerns the accessibility of the device; they also recommend that devices be secured and well marked.
- “One national law sets the program.” The CDC review examined laws jurisdiction by jurisdiction and found that none required all 13 elements.
FAQ
What is public access defibrillation?
A program approach, promoted by the American Heart Association according to the CDC review, that makes AEDs available to nonmedical first responders and lay bystanders and surrounds them with training, maintenance, EMS coordination, quality improvement and liability protection.
What is a public access defibrillator?
The AED itself as placed for public or workplace use. The device is one part of a PAD program.
Do US laws require all PAD program elements?
No. In the CDC review of 2010 laws, no jurisdiction required all 13 elements, although all provided some immunity to AED users.
Sources
- Gilchrist S, Schieb L, Mukhtar Q, Valderrama A, Yoon P, Sasson C, McNally B, Schooley M. A Summary of Public Access Defibrillation Laws, United States, 2010. Preventing Chronic Disease 2012;9:110196. CDC. cdc.gov/pcd/issues/2012/11_0196.htm (checked 2026-11-01).
- HHS Office of Public Health and Science and GSA Office of Governmentwide Policy. Guidelines for Public Access Defibrillation Programs in Federal Facilities. Federal Register 66(100), 23 May 2001, pp. 28495-28511. govinfo.gov (checked 2026-11-01).