Skip to main content
v2026.11,986 entries · CC-BY 4.0

PubMed BLAST: Is There One? How NCBI BLAST Works

PubMed searches literature and NCBI BLAST searches sequences. See how the two relate and how to run a web BLAST search.

Written and maintained by CASRAI Editorial Board

Published

On this page

There is no BLAST inside PubMed. PubMed is NCBI’s free search tool for biomedical and life-sciences literature, and it does not search DNA or protein sequences. BLAST (Basic Local Alignment Search Tool) is a separate NCBI service at blast.ncbi.nlm.nih.gov that compares a nucleotide or protein query against sequence databases. Both are run by the National Center for Biotechnology Information, which is why people search for them together as “PubMed BLAST”.

What “PubMed BLAST” means: two NCBI services, not one

According to PubMed’s own About page (read 2026-11-20), PubMed is a free resource for biomedical and life-sciences literature built by NCBI at the National Library of Medicine, holds more than 40 million citations and abstracts, and does not include full-text journal articles. Its sources are MEDLINE, PubMed Central and Bookshelf. A PubMed search returns papers, not alignments. If you want to learn how to build literature searches, see our guides to MeSH terms in PubMed, and the comparison of PubMed and PubMed Central.

NCBI’s BLAST handout “BLAST Homepage and Search Pages” (last updated April 4, 2025, read 2026-11-20) describes BLAST as a suite of programs for nucleotide and protein sequence similarity search. Developed by NCBI investigators, the algorithms create local alignments between query sequences and sequences in a database you select. The two services meet in only two practical places. Every BLAST method paper is itself indexed in PubMed, and the BLAST help pages cite those papers. NCBI’s BLAST references page lists the original method paper, Altschul, Gish, Miller, Myers and Lipman, “Basic local alignment search tool” (1990), which is the standard citation when you report a BLAST search in a manuscript.

Which one do you need?

The decision depends on what you hold and what you want back.

  • You have a sequence (a FASTA record or an accession such as NM_000249) and want to find similar sequences: use BLAST.
  • You want papers about a gene, method or disease: use PubMed.
  • You want the record for a gene or protein found by BLAST: continue to NCBI Gene, NCBI Protein or the GenBank nucleotide database.

Who runs BLAST and what it covers

BLAST on the web is operated by NCBI. The BLAST homepage groups its tools into Web BLAST, BLAST Genomes and Specialized searches. The header of the homepage carries Home, Recent Results, Saved Strategies, Help and a Log in button; the login is the free My NCBI account.

What a search covers depends on the database you choose, not on BLAST itself. NCBI’s database descriptions say that core_nt is a refined nucleotide database optimised for speed and search relevance, intended for characterising sequences and finding homologs. The data table below the article compares the five standard search pages. The table here compares the main databases you pick from, as listed in the NCBI handout and the BLAST databases help page.

Database Type Content as NCBI describes it
core_nt Nucleotide GenBank, EMBL, DDBJ and PDB sequences, non-redundant; excludes PAT, EST, STS, GSS, WGS, TSA, HTGS phase 0-2 entries and eukaryotic genomic assemblies
nt Nucleotide Same as core_nt, with eukaryotic genomic assemblies included
refseq_rna, refseq_select, refseq_reference_genomes, refseq_genomes Nucleotide RefSeq-based subsets offered on the nucleotide search page
nr Protein Non-redundant: GenBank CDS translations, RefSeq, PDB, SwissProt, PIR and PRF, excluding PAT, TSA and env_nr; this is the protein default
refseq_protein, swissprot, pdb, Landmark Protein Smaller or curated protein sets; swissprot is the last major release of UniProtKB/SWISS-PROT, with no incremental updates
ClusteredNR Protein Built from nr with MMseqs2, clustered at 90% identity and 90% length coverage, with a RefSeq sequence as representative where available

The same handout notes that the est and HTGS databases are stale, with no new entries. Treat the list as the state of the handout on its April 2025 date and check the live Database drop-down before relying on a particular set.

The BLAST Help quick-start guide lays the search out in a fixed order: choose a BLAST program, enter the query, choose the search set, select the program, and click BLAST. The steps below use the interface terms from NCBI’s handout, so they match what you see on screen.

  1. Open the right search page. From blast.ncbi.nlm.nih.gov, pick one of the five standard pages under Web BLAST (see the data table below).
  2. Enter Query Sequence. Paste an accession number or FASTA sequence, or use Choose File to upload a plain-text file of FASTA sequences. For a single input, the Query subrange boxes restrict the search to a segment of it.
  3. Optionally align your own sequences. The Align two or more sequences checkbox replaces the database list with an Enter Subject Sequence box so you compare two sets you supply.
  4. Choose Search Set. Select the database. The Organism box accepts a common name, genus and species, or a taxonomy ID (for example 9606); Add organism and the Exclude checkbox refine the set. For non-WGS, non-SRA nucleotide databases an Entrez Query box can restrict the search, for example by sequence length with 500:1000[slen]. Protein databases have no Entrez Query box.
  5. Program Selection. On the nucleotide page, megablast is the default and suits identifying a query or a large genomic entry; discontiguous megablast finds related sequences from other species; blastn suits cross-species searches and short matches.
  6. Review Algorithm parameters (optional). Max target sequences, Short queries (tuned for queries of 30 bases or residues or fewer), Expect threshold, Word size, Max matches in a query range, Match/Mismatch scores, Gap costs, and Filter and Masking (low-complexity filtering is the default). Protein searches add a scoring matrix (BLOSUM62 is the default, and PAM30 is selected for short queries) and Compositional adjustments.
  7. Click BLAST and read the results. The quick-start guide names the result views: Search Summary, then the Descriptions, Graphic Summary, Alignments and Taxonomy tabs, plus a Filter results option.

The FAQ adds that lowercase grey letters in a displayed query mean the low-complexity filter has masked that region, and that nucleotide BLAST adjusts parameters automatically for short sequences. For a primer pair, NCBI points you to Primer-BLAST instead; our guide to NCBI BLAST and Primer-BLAST for primers covers that route.

Results are temporary: RIDs, Recent Results and Saved Strategies

The handout states that BLAST results are kept for up to 36 hours. Every search receives a Request ID (RID) that appears in the Recent Results list, and an RID can be entered to retrieve a search, including one a colleague shared. Searches run while logged in keep the full 36 hours independent of the browser session. Saved Strategies are kept permanently and can be downloaded for use with standalone BLAST. In practice, save the strategy, or export the alignments, for any search you will cite, and record the RID, database and parameter settings in your lab notes. NCBI’s own help-desk checklist asks for the RIDs, the search page and the settings used when you report a problem.

Strengths and limits

Strengths

  • It is free and runs in a browser.
  • It offers a fast default (megablast) for identifying a query and slower, more sensitive options (discontiguous megablast, blastn, PSI-BLAST, DELTA-BLAST) for distant relatives.
  • Organism, Exclude and Entrez Query restrictions narrow the search set so the Max target sequences limit is spent on relevant records.
  • Saved Strategies make a search repeatable and portable to standalone BLAST.

Limits

  • Results expire after 36 hours, so a web result is not an archive.
  • BLAST finds local similarity. A hit says the query resembles a database sequence under your parameters, not that the two are functionally equivalent; the Expect threshold and filters decide what is reported.
  • Database choice changes the answer. core_nt leaves out eukaryotic genomic assemblies that nt includes, and SwissProt is a fixed release.
  • It does not search the literature. A BLAST hit shows a record, and you move to PubMed or a gene or protein page for the papers.

Alternatives and companion tools

NCBI offers specialised searches built on BLAST, and the BLAST Help page also links the command-line BLAST+ manual, downloads and a guide to running BLAST at a cloud provider. Outside NCBI, EMBL-EBI’s Job Dispatcher lists NCBI BLAST+, PSI-BLAST, FASTA, HMMER3 tools (phmmer, nhmmer) and others through a REST API. For protein records reached from a hit, see the NCBI Protein guide linked above.

Tool Provider What the provider says it does
Primer-BLAST NCBI Designs primers with the primer3 algorithm and checks template specificity with BLAST
SmartBLAST NCBI Processes a protein query and summarises the five best protein matches from well-annotated sequences
IgBLAST NCBI Searches immunoglobulin or T cell receptor sequences against germline databases for annotation
Standalone BLAST+ NCBI Command-line programs with their own manual, linked from BLAST Help; saved web strategies can be downloaded for it
Job Dispatcher sequence tools EMBL-EBI Lists NCBI BLAST+, PSI-BLAST, FASTA, HMMER3 and others through a REST API

NCBI’s handout gives a short troubleshooting list for searches that return too much or too little. To focus a search, add a database limit with the Organism or Entrez Query box so BLAST targets a subset of the database. To increase stringency, combine a lower Expect value, a larger Word size, filters and repeat masking. Smaller word sizes are more sensitive, so move in the opposite direction when a distant match is the goal. If the results look odd, check three things first: that you picked the search page that matches your query type, that the database is the one you meant (core_nt versus nt, or a RefSeq subset), and that Short queries is set appropriately for queries of 30 bases or residues or fewer.

Citing BLAST in a methods section

A reproducible BLAST statement names the search page and program, the database and the date searched, the query accession or description, and any non-default parameters such as the Expect threshold or word size. NCBI’s BLAST references page lists the method papers to cite alongside the web service, starting with the 1990 Altschul paper. Because the web databases change over time, the date and database name matter more than the program version. To retrieve those papers, search PubMed for the paper title.

Sources

Data: NCBI standard web BLAST search pages: query type, database type and programs

Compares the five standard Web BLAST search pages on the NCBI BLAST homepage by the query and database type each compares and the programs it offers, compiled from NCBI's BLAST Homepage and Search Pages handout (April 2025) and BLAST Help.

Period covered: 2025.

NCBI standard web BLAST search pages: query type, database type and programs
Search pageQuery vs databasePrograms offeredUse named by NCBI
blastnNucleotide vs nucleotidemegablast (default), discontiguous megablast, blastnSequence identification and intra-species comparison; cross-species comparison; shorter queries
blastpProtein vs proteinblastp (default), Quick BLASTP, DELTA-BLAST, PSI-BLAST, PHI-BLASTGeneral similarity search; distant relatives of a protein family via PSI-BLAST
blastxTranslated nucleotide vs proteinblastxIdentifying potential protein products encoded by a nucleotide query
tblastnProtein vs translated nucleotidetblastnIdentifying database sequences encoding proteins similar to the query
tblastxTranslated nucleotide vs translated nucleotidetblastxIdentifying nucleotide sequences similar to the query by coding potential

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about PubMed BLAST: Is There One? How NCBI BLAST Works

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →