A pyridine safety data sheet (SDS) describes a highly flammable, harmful liquid, CAS 110-86-1, carrying the signal word Danger. All three supplier sheets compared here classify it as Flammable Liquid Category 2 (H225) and Acute Toxicity Category 4 by the oral, dermal and inhalation routes (H302, H312, H332). They differ on skin and eye classification, on flash point (17 °C or 20 °C) and on how long the incompatibility list is, so the SDS that came with your own bottle is the one to follow.

What a pyridine SDS covers

Pyridine is identified on the sheets by CAS number 110-86-1 and EC number 203-809-9; the Honeywell sheet also lists the EU index number 613-002-00-7. Searchers use “pyridine MSDS” and “pyridine SDS” interchangeably: the older MSDS name and the current SDS name refer to the same supplier document. The sheets read for this page are laid out in the 16-section GHS format, and five sections do most of the work for laboratory staff and environmental health and safety (EHS) officers:

  • Section 2, hazard identification: the GHS classification, signal word, hazard (H) statements and precautionary (P) statements.
  • Section 7, handling and storage: container, ventilation, ignition-source and static-discharge instructions.
  • Section 9, physical and chemical properties: flash point, boiling point, flammable limits, auto-ignition temperature.
  • Section 10, stability and reactivity: conditions to avoid and incompatible materials.
  • Section 13, disposal considerations: the supplier’s statement on how waste is to be handled.

For a general walk-through of every section, see how to read a safety data sheet. This page applies that reading to one chemical and shows where three real pyridine sheets disagree. The data table after the sources below sets the three sheets side by side.

Pyridine hazards: GHS classification and H statements

The core of the classification is the same everywhere: pyridine is a highly flammable liquid and vapour (H225) and is harmful if swallowed, in contact with skin or if inhaled (H302, H312, H332). The signal word on the Honeywell and Lobachemie sheets is Danger. What changes between sheets is the rest of the profile.

Three sheets, three classification profiles

  • Honeywell Specialty Chemicals, pyridine 66213-1L (EU/REACH format, version 2.0, revision 24.03.2020, hosted by Fisher Scientific): Flam. Liq. 2 (H225); Acute Tox. 4 by the oral, dermal and inhalation routes (H302, H312, H332); Skin Irrit. 2 (H315); Eye Irrit. 2 (H319). It does not carry H314 or H318.
  • Lobachemie, PYRIDINE AR (REACH Regulation (EU) 2020/878, issued 24 November 2023, version 1.0): Flam. Liq. 2 (H225) and Acute Tox. 4 for the three routes (H302+H312+H332). Its toxicological section lists skin corrosion/irritation as “Not classified”.
  • ChemSupply Australia, pyridine HPAM7V9Z (UN GHS revision 7, issued 2024-06-26, version 1.0): Flam. Liq. 2; Acute Tox. 4 for the three routes; Skin Corr. 1C (H314, severe skin burns and eye damage); Eye Dam. 1; and STOT RE 2 (H373, specific target organ toxicity after repeated exposure).

The practical consequence is that the same CAS number can reach a bench with a skin-irritant label, with no skin classification at all, or with a corrosive one. The PubChem record for pyridine (NIH National Library of Medicine) shows why: it aggregates the classifications that companies notified to the European Chemicals Agency (ECHA) under CLP, across 2,399 reports and 22 notifications. H225 (99.8%), H302 (99.7%), H312 (99.7%) and H332 (99.8%) appear in nearly every report, while H315 appears in 17.5% and H319 in 16.5%. The flammability and acute-toxicity core is close to universal; the skin and eye classes are not. H314 shows up only in a minority notification.

The GHS system itself, including the category numbers and the meaning of the signal words, is explained in GHS classification of chemicals. PubChem also records the practical fire and irritation description: the vapour is heavier than air and may travel to a source of ignition and flash back, containers may explode when heated, and the liquid is irritating to the eyes, nose and throat and a severe eye irritant.

Precautionary statements and protective equipment

Supplier sheets carry the P statements that matter for daily use. The Lobachemie sheet’s P280 line calls for gloves, protective clothing, and eye and face protection. The ChemSupply sheet points to a standard for hand protection (AS 2161, an Australian standard) rather than naming a single glove material in its summary. Because glove selection depends on the exact product, the concentration and the contact time, take PPE specifics from section 8 of the sheet for your own product and from your institution’s chemical hygiene plan; this page does not substitute for either.

Pyridine flash point

The flash point is the most quoted number on a pyridine SDS, and it is not identical across sheets. The Honeywell sheet gives 20 °C (closed cup) and the Lobachemie physical-properties section also gives 20 °C. The ChemSupply sheet gives 17.0 °C (closed cup). Lobachemie’s transport section (IMDG) lists 17 °C c.c., so a single Lobachemie sheet contains both figures. The PubChem record carries a 68 °F (20 °C) closed-cup value from a 1992 National Toxicology Program entry.

All of these values are at or below typical room temperature, which is consistent with the Flam. Liq. 2 classification. Other numbers that appear on the sheets are more consistent: auto-ignition temperature 482 °C on all three, flammable limits of 1.8 to 12.4 volume % on the Lobachemie sheet and 1.80 to 12.40 % on the ChemSupply sheet, a boiling point of 115 °C and melting point of -42 °C on the Honeywell sheet. If a procedure or a risk assessment depends on a flash-point threshold, record which sheet and which method the number came from, and use the lower value where the sheets disagree and the decision is a safety one. That last point is editorial advice, not a statement from any of the sheets.

Pyridine storage and incompatibilities

The three sheets agree on the main storage instructions even where their wording differs:

  • Container and place: Honeywell says to keep it in the original container, tightly closed, in a dry, well-ventilated place at room temperature (above 0 and below 35 °C). Lobachemie calls for a fireproof place with the container tightly closed. ChemSupply says cool, well ventilated, out of direct sunlight and away from heat and ignition sources, sealed and protected from physical damage.
  • Ignition and static: Honeywell warns that heavy vapours can travel a considerable distance to a source of ignition and calls for precautions against static discharge. Lobachemie says to ground and bond the container and receiving equipment. ChemSupply calls for flameproof electrical equipment and static precautions.
  • Conditions to avoid: Honeywell lists heat, flames, sparks, extremes of temperature and direct sunlight.

Incompatible materials: short list versus long list

Here the sheets differ most. Honeywell’s section 10.5 lists strong oxidizing agents and strong acids. The Lobachemie sheet gives heat sources and no additional information under incompatible materials. The ChemSupply sheet gives a longer list that includes strong acids, formamide, iodine, fluorine, halogen compounds, maleic anhydride, nitric acid, nitrogen oxides, sulfur oxides, anhydrides, strong oxidising agents, perchlorates, chromates and bromine trifluoride; its list continues beyond what is quoted here. A shared chemical store should follow the most complete list available for the product it actually holds, not the shortest one, because a short list on one sheet is not evidence that other materials are safe to store alongside.

Flammable-liquid cabinet rules are summarised in flammable liquid storage cabinet requirements. Pyridine is a Category 2 flammable liquid under GHS on all three sheets; for another common laboratory solvent read through the same way, see toluene SDS.

Pyridine disposal and spill response

The disposal statements on the sheets are deliberately general. Honeywell’s section 13 says to dispose according to legal requirements. Lobachemie says to dispose of the contents and container at a hazardous or special waste collection point in accordance with local, regional, national and international regulation. Neither gives a chemical neutralisation or treatment method, and this page does not add one: treat pyridine waste as hazardous waste and route it through your institution’s waste programme. Where a laboratory accumulates waste at the bench, the rules are covered in satellite accumulation areas for chemical waste.

On spills, the Honeywell sheet says to soak the liquid up with an inert absorbent, collect it in closed containers for disposal and not to let it enter surface water or the sewer. PubChem makes the same point from the fire side: runoff to a sewer may create a fire or explosion hazard. For fire, the Honeywell sheet names water spray, foam, carbon dioxide and dry powder as suitable extinguishing media and warns against a high-volume water jet. Combustion produces carbon monoxide, carbon dioxide and nitrogen oxides.

Exposure limits for pyridine

Occupational exposure limits are listed in section 8 of each sheet and come from different bodies, which is why a single number is not the whole answer. The values below are the ones printed on the sheets read for this page.

Limit and body Value stated on the sheet Sheet
EH40 workplace exposure limit, long-term (TWA) 5 ppm (16 mg/m³) Honeywell
EH40 workplace exposure limit, short-term (STEL) 10 ppm (33 mg/m³) Honeywell
EU indicative limit value, TWA 5 ppm (15 mg/m³) Honeywell
Safe Work Australia, TWA 5 ppm (16 mg/m³) ChemSupply
US OSHA PEL-TWA (29 CFR 1910.1000 Table Z) 5 ppm ChemSupply
NIOSH REL 5 ppm ChemSupply
ACGIH TLV 1 ppm ChemSupply

The EH40, EU, Safe Work Australia, OSHA and NIOSH time-weighted values are all 5 ppm, while the ACGIH value on the ChemSupply sheet is 1 ppm. A limit from a guidance body such as ACGIH is not a legal limit, so which figure binds a given laboratory depends on its jurisdiction. The differences between PELs, TLVs and RELs, and how to apply them, are explained in permissible exposure limits in the laboratory. The ChemSupply sheet also shows NFPA ratings of 2 for health and 3 for flammability.

Why pyridine SDSs differ

Identical chemistry does not guarantee identical documents. Four differences were visible in the three sheets read here. First, the regional format: EU REACH-format sheets (Honeywell, Lobachemie) and a sheet written to UN GHS revision 7 for Australia (ChemSupply) carry different exposure-limit lists and different transport and regulatory sections. Second, the classification itself: suppliers self-classify within their legal framework, and the ECHA notification spread in PubChem shows that the skin and eye classes are not agreed. Third, the product grade and issue date: the sheets are dated from March 2020 to June 2024, and a sheet is correct for the product and date it was issued for. Fourth, internal consistency: one sheet can carry two flash-point values in different sections.

For lab managers who keep an SDS binder or an electronic library, this means filing the sheet that came with each purchased product, not a generic pyridine sheet from a search result.

Common misunderstandings about pyridine SDSs

  • “Every pyridine SDS is the same.” The three sheets compared share H225 and the three acute-toxicity statements but differ on skin and eye hazard, on a repeated-exposure statement (H373 appears on the ChemSupply sheet only), and on the length of the incompatibility list.
  • “The flash point is 20 °C.” That is the closed-cup figure on two sheets and in PubChem; the ChemSupply sheet and the IMDG line of the Lobachemie sheet give 17 °C.
  • “No H314 on my sheet means pyridine is never corrosive.” It means that supplier did not classify it that way. A different supplier’s sheet can legitimately differ, so check the sheet for the product in your hands.
  • “The SDS tells me how to dispose of it.” The sheets read here point to legal requirements and hazardous waste collection; the actual route is set by your institution’s waste programme and local regulation.
  • “MSDS and SDS are different documents.” MSDS is the older name; the supplier document covered here is the same one.

Sources

Data: Three pyridine safety data sheets compared: classification, flash point, auto-ignition and incompatibilities

Side-by-side comparison of three manufacturer safety data sheets for pyridine (CAS 110-86-1) from Honeywell, Lobachemie and ChemSupply, compiled from the sheets themselves. Shows where the GHS skin and eye classification, flash point and incompatibility lists differ between suppliers.

Period covered: 2020/2024.

Three pyridine safety data sheets compared: classification, flash point, auto-ignition and incompatibilities
Supplier sheetIssue dateSkin and eye classificationOther classification beyond H225 and Acute Tox. 4Flash point (closed cup) (°C)Auto-ignition temperature (°C)Incompatible materials listed
Honeywell Specialty Chemicals 66213-1L (v2.0, EU/REACH)2020-03-24Skin Irrit. 2 (H315); Eye Irrit. 2 (H319)None listed20482Strong oxidizing agents; strong acids
Lobachemie PYRIDINE AR (v1.0, REACH 2020/878)2023-11-24Skin corrosion/irritation: not classifiedNone listed20482Heat sources; no additional information (IMDG entry gives flash point 17 °C c.c.)
ChemSupply Australia HPAM7V9Z (v1.0, UN GHS rev 7)2024-06-26Skin Corr. 1C (H314); Eye Dam. 1STOT RE 2 (H373)17482Strong acids, formamide, iodine, fluorine, halogen compounds, maleic anhydride, nitric acid, strong oxidising agents, perchlorates, chromates, bromine trifluoride and others

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Pyridine SDS: Hazards, Flash Point, Storage and Disposal

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →