Sabouraud is a family of fungal culture media, commonly called Sabouraud dextrose agar (SDA), used to grow yeasts and molds. Its acidic and Emmons formulations differ, and added antimicrobials change which organisms are recovered. The formulation name and supplements matter as much as the word Sabouraud.

Short answer

A Sabouraud medium supports fungal cultivation, but it does not guarantee recovery of every fungus or establish a species identification by itself. The useful distinction is between the nutrient base, its acidity, and any selective additives. Chloramphenicol mainly targets competing bacteria; cycloheximide can suppress fungi, including some organisms a laboratory may want to detect. These are different kinds of selectivity, with different consequences for interpreting growth.

The data table below compares named reference and manufacturer formulations. It includes an important counterexample: reduced glucose can occur in an acidic medium as well as in an Emmons formulation. A label such as “Sabouraud, 2% glucose” therefore does not, by itself, establish the medium’s pH or recovery characteristics.

Definition and scope

Sabouraud agar, Sabouraud dextrose agar and Sabouraud glucose agar are names used for closely related fungal media. Dextrose refers to the glucose component. “Agar” identifies the solidifying ingredient; Sabouraud broth belongs to the same broader family but is liquid. These names describe culture environments rather than a single organism or a complete identification test.

The American Society for Microbiology’s account connects the medium’s development with studies of dermatophytes, fungi associated with skin, hair and nails. It also describes a second goal: obtaining comparable fungal appearances across laboratories. Consistent ingredients mattered because differences in the medium could change the appearance used to distinguish isolates. That connection remains useful when reading a method: the medium is part of the conditions under which the observation was made.

The scope extends beyond clinical microbiology, but intended use belongs to the particular formulation and product. Remel’s Emmons documentation describes clinical fungal isolation, while Gold Standard Diagnostics labels its BACGro SDA for laboratory cultivation rather than human disease diagnosis. Bio-Rad describes yeast and mold work with samples carrying relatively little bacterial contamination. These statements should retain their product context instead of becoming a blanket claim about every Sabouraud medium. For the wider field, see mycology and its laboratory methods.

How Sabouraud fungal media work

The basic components have separate functions. Peptones are protein digests supplying nitrogenous nutrients; glucose supplies usable carbon and energy; agar produces a solid surface. Both the BACGro and Remel descriptions explain the nutrient roles, although their formulations differ. The medium combines nutritional support with conditions that can favor fungi over competitors.

Acidity provides one selective effect. The FDA’s BAM M133 agar reference is acidic, and BACGro describes its low pH as slightly inhibitory to competing bacteria. “Slightly” matters: acidification is not evidence that a culture is free of bacteria. Thermo Fisher’s chloramphenicol-containing medium explicitly allows for growth of bacteria resistant to that antimicrobial. A colony on fungal medium must therefore be interpreted in the context of the medium’s actual limits.

Additives supply another selective effect. Remel describes chloramphenicol and gentamicin as antibacterial agents, whereas cycloheximide inhibits some rapidly growing saprophytic fungi. Its limitations also identify potentially pathogenic fungi that cycloheximide can inhibit. Suppressing background growth can make a target easier to recover, but the same selection can exclude other targets. A cleaner-looking culture is not automatically a more complete account of the original sample.

Growth and identification are separate findings. Thermo Fisher’s slant documentation treats identifications as presumptive and calls for confirmation; Micromaster likewise describes additional identification work. SDA supplies growth for further examination. It is not a species-specific answer merely because the sample produced a yeast colony or mold mycelium.

Acidic Sabouraud and the Emmons modification

The classical acidic formulation and Emmons modification should be distinguished by the complete formula. Remel describes Emmons as a change toward neutral pH with less dextrose. Its stated base is different from the FDA agar reference. However, Bio-Rad’s Bulletin 5117 also describes an acidic Sabouraud formulation with reduced glucose. This is why a single ingredient concentration cannot reliably stand in for the formulation’s identity.

The comparison dataset preserves the named source of each row. It is a reference to published compositions, not a preparation recipe or a declaration that the products are interchangeable. Differences in peptone descriptions, solidifying ingredient and pH remain visible rather than being compressed into one supposed universal Sabouraud formula.

Antibacterial additives and fungal inhibitors

A name ending “with chloramphenicol” describes a different selective environment from one also containing cycloheximide. The latter deserves particular attention in broad fungal investigations. Micromaster’s DM605 performance table reports strong dermatophyte growth alongside restricted growth of several other fungal controls. That is consistent with its selective purpose; it is not evidence that all yeasts and molds should grow equally well.

These distinctions explain why manufacturers describe companion media. Both Remel and Thermo Fisher discuss selective and nonselective media together. Their documentation supports evaluating the recovery strategy as a combination of media, rather than assuming that adding more inhibitors makes one medium sufficient for every sample.

Sabouraud broth and other fungal media

Liquid and solid versions also need separate descriptions. Oxoid CM0147 lists glucose and two protein digests without an agar ingredient; its yeast controls are described through turbid growth. FDA M133 presents a different broth reference and a corresponding agar version. The shared family name does not establish identical glucose content across those documents.

Sabouraud is also distinct from other fungal media with different bases or readouts. The companion guides on potato dextrose agar plates and CHROMagar Candida and colony-color interpretation explain those separate concepts. A medium’s name, nutritional basis and interpretation belong together when comparing methods.

Where it matters for labs, clinics and supply decisions

For a laboratory reviewing a method or a medium description, the following checklist brings together distinctions explicitly present in the manufacturer and FDA documents. It concerns the identity and limitations of the medium, without ranking suppliers or proposing a universal replacement.

  • Formulation identity: compare the named variant, pH and nutrient base. FDA M133, Remel Emmons and Bio-Rad Bulletin 5117 demonstrate why the family name alone is incomplete.
  • Selective ingredients: establish whether antibacterial agents, cycloheximide or both are present. Remel and Micromaster document different recovery effects associated with these additions.
  • Intended application: retain the manufacturer’s clinical or nonclinical scope. BACGro’s diagnostic exclusion and Thermo Fisher’s professional diagnostic application are different claims about different products.
  • Performance evidence: read the control organisms and expected reactions for that formulation. Growth promotion and inhibition provide different evidence; neither can be inferred from the product name.
  • Condition and traceability: associate the product with its lot documentation and condition requirements. BACGro describes lot testing and certificates of analysis; Thermo Fisher excludes damaged, contaminated or deteriorated medium.

This also separates manufacturing quality control from the laboratory’s own obligations. Bio-Rad states that its batches undergo checks according to EN ISO 11133. That is an attributed manufacturer statement, not proof that every Sabouraud product has the same certification or performance. BACGro separately calls for end-user quality control consistent with applicable requirements. A supplier’s acceptance result and a laboratory’s suitable-use decision answer different questions.

Media condition can change whether a result is usable. BACGro discusses moisture-related deterioration of dehydrated medium and warns that overheating acidic agar can soften it. These observations explain why a formula on paper does not establish the condition of a particular preparation. The broader culture media preparation and quality-control guide covers that supporting laboratory context.

Culture results and quality control

A control result belongs to the documented combination of formulation, organism and testing conditions. In Remel’s Emmons tables, some fungal controls grow on the base medium but are inhibited when cycloheximide is present. Micromaster’s supplemented medium has its own stated growth categories, including restricted growth for its Candida albicans control. These tables should not be combined into a universal list of organisms that “grow on Sabouraud.”

The distinction is especially relevant when comparing an observation with a reference description. A result recorded as poor growth is not equivalent to a result recorded as no growth, and manufacturer terms such as partial inhibition do not establish complete exclusion. The source’s wording and strain context preserve the limits of the evidence. Transferring an expected response from one supplemented formulation to another would remove those qualifications.

Nutritional requirements impose additional limits. Thermo Fisher identifies Malassezia furfur as requiring lipid supplementation and notes that some strains may grow poorly or fail to grow. BACGro also acknowledges variable nutritional requirements. Absence of growth on one Sabouraud formulation cannot establish that every potentially relevant fungus was absent from the sample.

Common misunderstandings

“Selective” means bacteria cannot grow. Selectivity describes inhibition under particular conditions. BACGro’s qualified description of acidity and Thermo Fisher’s resistant-bacteria warning both rule out treating the name SDA as a guarantee of a purely fungal culture.

Emmons means any low-glucose Sabouraud medium. The acidic Bio-Rad formulation and acidic Oxoid liquid medium are counterexamples. Reduced glucose and near-neutral pH are separate characteristics. Neither should be supplied from memory when only the other is documented.

Cycloheximide removes only unwanted fungi. The inhibited organism may itself be relevant to the investigation. Product-specific fungal limitations and companion-medium guidance explain why selectivity must be considered alongside the target organisms.

Visible fungal growth completes identification. The manufacturer documents distinguish cultivation from confirmation. The observation should retain that distinction, including any further identification methods required by the laboratory’s established workflow.

A familiar medium is harmless to handle. ASM highlights dispersible fungal spores, while BACGro restricts use to trained personnel and treats cultures as potentially infectious. The medium’s routine laboratory role does not remove the biological hazards of what grows on it.

Sources

Data: Sabouraud formulations across reference and manufacturer documents

Original compilation of five named Sabouraud formulations from FDA BAM M133 and Remel, Bio-Rad, Oxoid and Micromaster documents. Values describe the listed base or supplemented formula, not interchangeable products or preparation instructions. Total peptone combines listed protein digests; nominal pH excludes the stated tolerance. The agar range is retained as a range.

Sabouraud formulations across reference and manufacturer documents
Named formulationMedium stateGlucose or dextrose (g/L)Total listed peptone (g/L)Agar (g/L)Nominal final pHAdded antimicrobials in listed formulaSource document
FDA Sabouraud dextrose agarSolid401015–205.6None listedFDA BAM M133
Remel Sabouraud dextrose agar, Emmons baseSolid2010157None in base; optional variants separateRemel IFU1760
Bio-Rad Sabouraud agar 12017522Solid2010125.8None listed; optional additions discussedBio-Rad Bulletin 5117 Ver A
Oxoid Sabouraud dextrose liquid medium CM0147Liquid201005.6None listedOxoid CM0147 BT-SPEC-0098
Micromaster Sabouraud cycloheximide chloramphenicol agar DM605Solid2010156.8Chloramphenicol and cycloheximideMicromaster DM605 specification

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Sabouraud Agar: Fungal Media and Formulation Limits

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →