Written and maintained by CASRAI Editorial Board
Published
On this page
samtools idxstats is a specialized utility in the SAMtools suite that retrieves alignment summary statistics directly from the index file (such as a .bai or .csi file) of a coordinate-sorted BAM, CRAM, or SAM file. By extracting pre-computed index bin counts rather than reading through multi-gigabyte sequence records, samtools idxstats executes almost instantaneously, outputting a four-column tab-delimited table detailing reference sequence names, sequence lengths, mapped read-segment counts, and unmapped read-segment counts for each chromosome or contig. Bioinformaticians rely on this command as an essential quality-control checkpoint to verify chromosome-level read distributions, validate sex chromosome ratios, detect foreign DNA contamination, and confirm library balance across sequencing cohorts prior to running downstream variant calling or expression analysis.
What samtools idxstats is used for in research
High-throughput sequencing workflows generate millions of reads aligned to reference assemblies. Once short or long reads are aligned using tools like Bowtie 2 or BWA-MEM, researchers must confirm that alignments match expected biological parameters before investing compute time in variant calling or transcript quantification. Sequence alignments are stored in compressed formats described in our guide to BAM files and evaluated across formats in our comparison of SAM, BAM, and CRAM. Because complete alignment files routinely exceed tens of gigabytes, streaming through every record to check mapping distributions creates unnecessary computational bottlenecks.
This is where samtools idxstats provides immediate utility. When an alignment file is coordinate-sorted and indexed, as detailed in our guide on BAM index (.bai) files, the index stores metadata summarizing virtual file offsets and record counts for each contig. samtools idxstats queries this compact index structure in milliseconds. In research laboratories and sequencing core facilities, investigators use samtools idxstats for several primary tasks:
- Sequencing Quality Control: Providing an immediate check to ensure alignments completed properly and reads distributed across expected chromosomes rather than falling into unmapped bins.
- Sex Determination and Chromosomal Dosage: In mammalian genomics, calculating read count ratios between chromosome X, chromosome Y, and autosomes enables researchers to verify sample sex, detect sample swaps in cohort studies, and flag chromosomal aneuploidies.
- Contamination and Organellar Screening: Evaluating read counts aligned to mitochondrial DNA (chrM/MT), chloroplast genomes, or spike-in controls (such as PhiX174) quantifies cytoplasmic carryover, library preparation efficiency, and sample purity.
- Targeted Capture Verification: In exome or targeted panel sequencing, comparing on-target chromosome counts against off-target regions provides fast feedback on hybridization capture efficiency.
- Automated Pipeline Reporting: Workflow engines like Nextflow and Snakemake run
samtools idxstatsimmediately after alignment, feeding per-chromosome statistics into MultiQC reports without file I/O overhead.
How to install or access samtools idxstats
samtools idxstats is included within the core SAMtools package, developed and maintained by the HTSlib team and Genome Research Limited. Users do not need an independent binary. SAMtools can be installed across Unix-like systems through official channels:
Package Managers (Bioconda and Conda)
In academic bioinformatics, Bioconda is the standard distribution channel. To install SAMtools into an existing conda environment, execute:
conda install -c bioconda -c conda-forge samtools
To create an isolated environment with SAMtools installed, run:
conda create -n bioinfo -c bioconda -c conda-forge samtools
conda activate bioinfo
System Repositories (Debian and Ubuntu)
On Debian, Ubuntu, and related Linux distributions, pre-compiled binaries are available through APT:
sudo apt update
sudo apt install samtools
On Red Hat Enterprise Linux, CentOS, or Rocky Linux, packages are available via EPEL or Fedora repositories using dnf:
sudo dnf install samtools
Compiling from Official Source
For high-performance computing clusters requiring custom compiler optimizations, download the official release tarball from HTSlib and build locally:
wget https://github.com/samtools/samtools/releases/download/1.21/samtools-1.21.tar.bz2
tar -xjf samtools-1.21.tar.bz2
cd samtools-1.21
./configure --prefix=/usr/local
make
sudo make install
Prerequisite development libraries include libncurses5-dev, zlib1g-dev, libbz2-dev, and liblzma-dev.
Container Environments
For containerized workflows, verified Docker and Singularity images are hosted on BioContainers. Run SAMtools via Docker with:
docker run --rm -v $(pwd):/data quay.io/biocontainers/samtools:1.21--h50ea8bc_0 samtools --version
How to run samtools idxstats step by step
Running samtools idxstats requires coordinate-sorted and indexed alignments. Follow these five steps to prepare files, execute the command, and process results:
-
Check Alignment Sort Order:
Verify that the alignment file is coordinate-sorted by inspecting the header:samtools view -H input.bam | grep '@HD'. The header must displaySO:coordinate. If the file is queryname-sorted (SO:queryname) or unsorted, index generation will fail. -
Coordinate-Sort the Alignment:
If the alignment is not yet sorted by coordinate, sort it using multi-threaded compression:samtools sort -@ 4 -o sample.sorted.bam sample.bamThis organizes records into ascending genomic coordinate order according to the sequence dictionary.
-
Generate the Index File:
Build the linear coordinate index usingsamtools index:samtools index -@ 2 sample.sorted.bamThis produces a standard index file named
sample.sorted.bam.bai. For genomes containing individual scaffolds longer than 512 megabases (536,870,912 bp), standard BAI bins overflow. In such cases, generate a Coordinate-Sorted Index (CSI) by adding the-cflag:samtools index -c -m 14 sample.sorted.bam -
Execute samtools idxstats:
Runsamtools idxstatsagainst the indexed BAM file, redirecting output to a tab-delimited text file:samtools idxstats sample.sorted.bam > sample.idxstats.tsvIf the index is located in a separate directory or has a non-default name, specify both paths using the
-Xoption:samtools idxstats -X /alignments/sample.sorted.bam /indices/sample.sorted.bam.bai > sample.idxstats.tsv -
Filter and Analyze Output Metrics:
Process the resulting table using standard Unix utilities. To view contigs ordered by mapped read counts in descending order, run:sort -k3,3nr sample.idxstats.tsv | head -n 10To calculate total mapped read-segments across all reference contigs (excluding unmapped reads), use
awk:awk '$1 != "*" {mapped += $3} END {print "Total Mapped Segments: " mapped}' sample.idxstats.tsvTo calculate the proportion of reads mapped to mitochondrial DNA, execute:
awk '{total += $3 + $4; if ($1 == "chrM" || $1 == "MT") m = $3} END {printf "Mitochondrial Rate: %.4f%% ", (m/total)*100}' sample.idxstats.tsv
How to read the output
The output of samtools idxstats is printed to standard output as a four-column tab-delimited table. Each line corresponds to an individual reference contig present in the alignment header, concluding with a final summary row representing unplaced reads:
| Column Number | Field Name | Data Type | Description and Interpretation |
|---|---|---|---|
| 1 | Reference Sequence Name | String | Identifier of the reference contig (e.g., chr1, chrX, NC_000001.11, or *) matching the @SQ SN: header tag. |
| 2 | Sequence Length | Integer | Length of the reference contig in base pairs, taken from the @SQ LN: header tag (0 for the unmapped * row). |
| 3 | Mapped Read-Segments | Integer | Number of aligned read-segments mapped to this reference sequence. |
| 4 | Unmapped Read-Segments | Integer | Number of unmapped read-segments whose mate mapped to this sequence, or total unplaced reads on the * row. |
Below is a representative sample excerpt from a paired-end human sequencing dataset mapped against GRCh38:
chr1 248956422 18420194 14205
chr2 242193529 17904312 13891
chrX 156040895 11420801 9102
chrY 57227415 142011 1540
chrM 16569 854201 212
* 0 0 482910
Read-Segments Versus Physical DNA Fragments
A vital distinction when interpreting Column 3 is that SAMtools counts read-segments rather than physical library fragments. In paired-end sequencing, each DNA fragment yields two reads (Read 1 and Read 2). When both reads map to chr1, Column 3 increments by 2, not 1. Furthermore, if secondary alignments (multi-mapping reads) or supplementary alignments (chimeric reads) are recorded in the index, each alignment record is counted. Consequently, the sum of Column 3 across all contigs can exceed the number of physical sequenced fragments. When converting alignments back to raw sequences, consult our guide on converting BAM to FASTQ to ensure read pairing integrity.
Interpreting Column 4: Unmapped Read-Segments per Contig
Researchers often wonder why specific chromosomes report unmapped read counts in Column 4. Under the SAM specification, when one read of a pair maps to a chromosome (such as chr1) but its mate fails to map, the aligner marks the mate as unmapped (FLAG bit 0x4) but records the mate’s reference name (RNAME) and coordinate (POS) matching the mapped partner. The index records these unmapped mates under that chromosome’s coordinate bin. Column 4 therefore quantifies unmapped read-segments whose mates mapped to that specific chromosome.
The Asterisk (*) Summary Row
The terminating line with an asterisk (*) represents completely unplaced reads. These are records where neither the read nor its mate mapped to any reference contig, or records without assigned coordinates (RNAME *, POS 0). For this line, Column 2 and Column 3 are always 0, and Column 4 reports the global count of completely unplaced reads. For deeper analysis of bitwise alignment states, see our practical guide on decoding SAM/BAM FLAG values.
Troubleshooting samtools idxstats
When incorporating samtools idxstats into bioinformatics pipelines, common errors typically involve index availability, sort order, or coordinate ranges:
Missing Index File
Symptom: The command fails with [E::hts_idx_load3] Could not load index file for 'sample.bam'.
Cause: SAMtools expects sample.bam.bai or sample.bam.csi in the same folder. If the index was omitted or renamed, the tool cannot locate it.
Resolution: Generate the index using samtools index sample.bam. If stored elsewhere, specify the index explicitly using the -X parameter: samtools idxstats -X /data/sample.bam /indices/sample.bam.bai.
Unsorted or Name-Sorted BAM Input
Symptom: The command prints a warning that the file is not coordinate-sorted, or it executes very slowly while scanning the full file.
Cause: On unindexed or name-sorted files, samtools idxstats falls back to a linear full-file scan. While it eventually prints correct counts, execution time increases from seconds to minutes.
Resolution: Sort the file by coordinate using samtools sort -@ 4 -o sample.sorted.bam sample.bam, index it with samtools index sample.sorted.bam, and re-run idxstats.
Index File Older Than Alignment File
Symptom: Terminal logs report [W::hts_idx_load3] the index file is older than the data file.
Cause: The modification timestamp on the .bai file is older than the BAM file timestamp. This occurs when BAM files are touched or moved after indexing.
Resolution: If the BAM contents did not change, synchronize timestamps using touch sample.bam.bai. If the BAM was modified, re-index with samtools index -f sample.bam.
Coordinate Overflow on Large Contigs
Symptom: samtools index fails with an error indicating a sequence coordinate exceeds the maximum limit for BAI format (512 Mbp).
Cause: Standard BAI format uses a hierarchical binning scheme capped at 536.87 Mbp (229 – 1 bp). Large plant or amphibian chromosomes exceed this limit.
Resolution: Build a Coordinate-Sorted Index (CSI) using samtools index -c -m 14 sample.bam. samtools idxstats reads CSI indices transparently.
Discrepancy with samtools flagstat Counts
Symptom: Summing Column 3 in idxstats does not equal the mapped read tally reported by samtools flagstat.
Cause: idxstats counts all alignment entries in the index, including secondary and supplementary alignments. samtools flagstat differentiates primary from secondary alignments.
Resolution: To count primary alignments only, filter alignments prior to inspection using samtools view -b -F 0x904 sample.bam | samtools idxstats -.
Free alternatives to samtools idxstats
While samtools idxstats is the standard for rapid index-based chromosome statistics, several open-source tools provide alternative or expanded alignment summaries:
| Tool Name | Developer / Project | Requires Index | Execution Speed | Primary Focus | Output Scope |
|---|---|---|---|---|---|
| samtools idxstats | HTSlib / Samtools Team | Yes (.bai / .csi) | Near-instantaneous (O(1)) | Per-contig mapped and unmapped read-segment counts | Contig summary table |
| samtools flagstat | HTSlib / Samtools Team | No | Moderate (stream scan) | Bitwise flag proportions (duplicates, proper pairs) | Library summary report |
| samtools coverage | HTSlib / Samtools Team | Yes (.bai / .csi) | Moderate (indexed scan) | Breadth of coverage, mean depth, base and map qualities | Contig depth table |
| samtools stats | HTSlib / Samtools Team | No | Thorough (record scan) | Insert size distributions, error rates, GC profiles | Multi-section report |
| bamtools stats | Barnett et al. (Marth Lab) | No | Moderate (stream scan) | General alignment tallies, single/paired read metrics | Terminal text output |
| Picard CollectAlignmentSummaryMetrics | Broad Institute | Yes (.bai) | Moderate (Java JVM) | Read-group metrics, mismatch rates, adapter content | Tabular metric file |
| Mosdepth | Brent Pedersen / Quinlan Lab | Yes (.bai / .csi) | Fast (parallel C/Nim) | Base-level depth, windowed coverage distributions | BED and summary files |
The data table below compares alignment inspection and metrics utilities across the HTSlib software suite. Choose the tool that matches your analytical scope: use samtools idxstats for instantaneous chromosome-level QC and sex validation; use samtools flagstat to monitor library-level duplicate and mapping percentages; and use samtools coverage or Mosdepth when evaluating base-pair depth and physical coverage breadth.
Frequently asked questions
How is samtools idxstats different from samtools flagstat or samtools stats?
samtools idxstats queries pre-computed index files directly without reading individual sequence records, producing an instant per-chromosome breakdown of mapped and unmapped reads. In contrast, samtools flagstat performs a full linear stream scan to calculate library-wide flag proportions, such as duplicate rates and proper pair percentages. samtools stats carries out an exhaustive record-by-record analysis to compute insert size distributions, cycle-by-cycle error rates, and GC content, requiring substantially more compute time.
Why does samtools idxstats count reads multiple times?
samtools idxstats tallies alignment records (read-segments) rather than physical DNA fragments. In paired-end sequencing, both reads of a mapped pair are counted individually, incrementing the mapped count by two. In addition, when aligners output secondary alignments for multi-mapping reads or supplementary alignments for split reads, each alignment record indexed in the BAM file contributes to its contig count.
What does the asterisk row mean in samtools idxstats output?
The asterisk (*) row at the bottom of the samtools idxstats output represents completely unplaced and unmapped reads. These records correspond to reads where neither the read nor its mate mapped to any reference contig, or records without assigned coordinates. For this row, sequence length (Column 2) and mapped count (Column 3) are 0, while Column 4 reports the total count of unplaced reads.
Can samtools idxstats run on a name-sorted BAM file?
samtools idxstats cannot perform instant index lookups on a name-sorted BAM file because linear index files require coordinate sorting. While samtools idxstats will attempt to process an unindexed or name-sorted file by scanning every record linearly, this fallback is much slower and eliminates the primary advantage of the command. Alignment files should always be coordinate-sorted with samtools sort and indexed with samtools index first.
What are unmapped read-segments in column 4 of samtools idxstats?
Unmapped read-segments in Column 4 of a chromosome row represent reads that failed to align, but whose paired mate aligned successfully to that chromosome. Under the SAM specification, an unmapped read with a mapped mate is assigned the reference name and coordinate position of its mapped partner. Consequently, the index records these unmapped mates under that chromosome’s bin, allowing researchers to evaluate discordant read pairs directly.
Sources
- HTSlib: samtools-idxstats(1) manual page, checked 2026-11-19
- HTSlib: samtools-index(1) manual page, checked 2026-11-19
- HTSlib: samtools(1) manual page, checked 2026-11-19
- Bioconda: Package Recipe ‘samtools’ — Bioconda documentation, checked 2026-11-19
- Debian Manpages: samtools-idxstats(1) — samtools — Debian testing — Debian Manpages, checked 2026-11-19
- Ubuntu Manpages: samtools-idxstats – reports alignment summary statistics, checked 2026-11-19
Data: HTSlib Alignment Inspection and Metrics Utility Matrix
A comparative technical matrix evaluating sequence alignment inspection and summary tools within the HTSlib samtools software ecosystem, detailing required index structures, computational complexity, stream compatibility, and output metric resolution across genomic analysis pipelines.
Period covered: 2026. Coverage: Global.
| Tool Utility | Primary Metrics Reported | Requires Coordinate Index (Boolean) | Computational Complexity | Output Granularity | Stream Piped Input (Boolean) |
|---|---|---|---|---|---|
| samtools idxstats | Per-contig mapped and unmapped read-segment counts and reference lengths | 1 | O(1) index parse | Per-chromosome tabular breakdown | |
| samtools flagstat | Total reads, secondary alignments, supplementary, duplicates, and paired read flags | O(N) single-pass scan | Whole-file library flag summary | 1 | |
| samtools stats | Exhaustive metrics including insert size distribution, mismatch rates, GC content, and read lengths | O(N) deep record scan | Multi-section detailed report | 1 | |
| samtools coverage | Per-chromosome coverage percentage, mean depth, base quality, and mapping quality | 1 | O(N) indexed scan | Per-chromosome tabular metrics | |
| samtools depth | Single-base position depth across specified genomic coordinates | 1 | O(N) coordinate stream | Per-base coordinate positions | 1 |
| samtools bedcov | Total read count and base count overlapping specified BED intervals | 1 | O(N) regional index lookup | Per-interval summary counts |
Sources
- HTSlib: samtools-idxstats(1) manual page (accessed 2026-11-19)
- HTSlib: samtools(1) manual page (accessed 2026-11-19)
- HTSlib: samtools-index(1) manual page (accessed 2026-11-19)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.