Skip to main content
v2026.11,986 entries · CC-BY 4.0

Schild Analysis: How to Build a Schild Plot and Read pA2 and Slope

Schild analysis turns antagonist-induced curve shifts into dose ratios, a Schild plot, a slope and a pA2, with a worked 2026 CGRP example.

Written and maintained by CASRAI Editorial Board

Published

On this page

Schild analysis is a way to test whether an antagonist works by competing with an agonist for the same receptor, and to put a number on its affinity. You measure the agonist concentration-response curve with and without fixed concentrations of the antagonist, convert each rightward shift into a dose ratio, and plot log(dose ratio − 1) against log antagonist concentration. A straight line with a slope of 1 is consistent with simple competitive antagonism, and the x-axis intercept gives pA2.

What Schild analysis measures

The method comes from Arunlakshana and Schild’s 1959 paper in the British Journal of Pharmacology, “Some quantitative uses of drug antagonists” (PubMed 13651579). Its abstract describes pA(x) measurements built on the hypothesis that an agonist and its antagonist compete for receptors according to the mass law. The authors used the approach to identify agonists acting on the same receptors and to compare the receptors of different tissues, and they reported tests of competitive and noncompetitive antagonism for acetylcholine with atropine, histamine with atropine and acetylcholine with cinchonidine. They also introduced a separate measure, pA(h), for unsurmountable antagonists.

Kenakin’s 1982 review, “The Schild regression in the process of receptor classification” (Canadian Journal of Physiology and Pharmacology, PubMed 7042056), is the clearest statement of what the regression is for. It is a tool for receptor classification: if the same antagonist gives the same affinity estimate against different agonists or in different tissues, the receptors involved are likely the same. In the 2026 glossary of Raffa and colleagues, a Schild plot is described as a graphical method for quantifying competitive antagonism in which the x-axis intercept yields the antagonist’s equilibrium dissociation constant (Cureus 2026, PMC13380234).

In practice this is a functional, tissue- or cell-based assay readout. It sits alongside binding approaches such as the Scatchard plot and potency conversions such as the Cheng-Prusoff equation, and it relies on the same kind of four-parameter curve fitting used for any sigmoidal concentration-response data.

Dose ratio and the Schild equation

The dose ratio

The dose ratio (DR) compares how much agonist you need with the antagonist present against how much you need without it. In the methods of a 2026 study on calcitonin gene-related peptide (CGRP) fragments, DR is defined as the agonist EC50 in the presence of the antagonist divided by the EC50 without it (J Headache Pain 2026, PMC13196087). A DR of 1 means no shift. A DR of 2 means the antagonist made the agonist need twice the concentration for the same half-maximal response.

The equation

Kenakin gives the Schild equation as log(DR − 1) = n·log[B] − log KB, where [B] is the antagonist concentration, KB is the antagonist’s equilibrium dissociation constant and n is the slope. You regress log(DR − 1) on log[B]. If the regression is linear with a slope of unity, the data are consistent with simple competitive antagonism, and the intercept estimates KB as the empirical pA2.

A short piece of illustrative arithmetic (not study data) shows why the intercept works. With n = 1, a DR of 2 makes log(DR − 1) equal to log(1), which is 0. The equation then reduces to 0 = log[B] − log KB, so log[B] = log KB. The antagonist concentration that produces a twofold shift in agonist EC50 therefore equals KB, and pA2, the negative logarithm of that concentration, equals −log KB. The CGRP paper states the same idea in words: pA2 refers to the logarithmic concentration of antagonist capable of producing a twofold shift in agonist EC50.

Where the Hill equation fits

The Hill equation family describes how a response or receptor occupancy rises with concentration. The Raffa 2026 paper traces the hyperbolic relation between concentration, dissociation constant (KD) and fractional occupancy to Hill (1909) and Clark (1926, acetylcholine on the frog rectus muscle), and notes that this relation underlies EC50 and IC50 estimation and Schild plots. So the Hill equation is not an alternative to Schild analysis: it is part of the occupancy model on which the curves you fit, and the shifts you convert into dose ratios, depend. The separate question of what the Hill coefficient means is covered in our Hill coefficient guide.

How to build a Schild plot, step by step

The recipe below follows the data handling in the 2026 CGRP study, with the equation from Kenakin. It is a data-analysis workflow, not a clinical procedure.

  1. Record a control concentration-response curve. In the CGRP study, segments of the same artery were used so that each antagonist concentration could be compared with a control curve from the same tissue.
  2. Record parallel curves with a fixed antagonist concentration in each. Each parallel segment received one fixed concentration of antagonist before the agonist was added.
  3. Fit each curve and extract the EC50. The study used a four-parameter fit in GraphPad Prism.
  4. Calculate DR for each antagonist concentration. DR = EC50 with antagonist divided by EC50 without.
  5. Plot log(DR − 1) against log antagonist concentration. Regress the points linearly. The study read pA2 from the x-intercept and reported a 95% confidence interval.
  6. Test the slope against 1. The study used a one-sample t-test of the slope against 1.
  7. If the slope is not different from 1, you may constrain it. Where antagonism was seen, the authors derived pA2 from a global Gaddum/Schild analysis with the slope constrained to 1.

How to interpret a Schild plot: slope and pA2

Read the plot in two passes: first the shape of the raw curves, then the regression. Kenakin lists what must hold for the regression to be meaningful. A competitive antagonist must give parallel displacement of the agonist curves, with no change in the maximal response, and dose ratios that are unambiguous and independent of the agonist concentration used to measure them. If the curves flatten or the maximum falls, the Schild line is not telling you what you think it is.

Then look at the slope. Per Kenakin, a slope of unity is consistent with simple competitive antagonism. A slope significantly different from 1 may mean the antagonism is not competitive, or that the experiment did not reach equilibrium. Kenakin also discusses slopes below and above 1, and notes that even a slope of unity can still give an erroneous KB. A slope of 1 is therefore necessary evidence, not proof.

Worked example from a published 2026 study

The CGRP study tested two peptide fragments, hαCGRP8-37 (described as the most characterised peptide CGRP-receptor antagonist) and hαCGRP11-37, against αCGRP in artery segments. Both produced progressive rightward shifts without lowering the maximal relaxation. The reported Schild results are:

Antagonist Schild slope Slope vs 1 (one-sample t-test) pA2 (95% CI)
hαCGRP8-37 0.85 p = 0.168 7.80 (7.61-8.11)
hαCGRP11-37 0.77 p = 0.121 6.66 (6.29-7.52)

Reading it: neither slope differs significantly from 1, so the data are compatible with competitive behaviour. A slope of 0.85 or 0.77 is not exactly 1, but the test cannot distinguish them from 1 with these data. The pA2 gap is 1.14 log units (7.80 − 6.66), which the authors describe as about tenfold lower potency for the 11-37 fragment. The confidence interval for the 11-37 fragment is much wider than that for 8-37, so its pA2 is the less certain of the two.

What is the pA2 value in pharmacology?

pA2 is the negative logarithm of the antagonist concentration that shifts the agonist EC50 twofold. Higher values mean a more potent antagonist, because less of it is needed to produce the same shift. In the table above, 7.80 means a lower concentration is needed than for 6.66.

Two distinctions matter. First, Kenakin calls the intercept the empirical pA2 and the thing it estimates KB: pA2 is what you read off the plot, KB is the affinity constant you hope it represents, and the two coincide only when the competitive model holds with a slope of 1. Second, Arunlakshana and Schild introduced pA(h) for unsurmountable antagonists, where the maximum cannot be restored by more agonist. For those, a pA2 from a standard Schild plot is not the right summary.

Can you give an example of a competitive antagonist?

Yes. In the 2026 study above, hαCGRP8-37 acts against αCGRP: increasing fixed concentrations produced a progressive rightward shift of the agonist curve, the maximal relaxation was unaffected and the Schild slope (0.85) did not differ from 1. The 1959 Arunlakshana and Schild paper is the historical source for the approach and included the acetylcholine-atropine and histamine-atropine pairs among its tests of competitive versus noncompetitive antagonism. Whether a given pair behaves competitively in your preparation is an experimental question, answered by the criteria in the previous section, not a property you can assume from the drug names.

Common misunderstandings and failure modes

  • “A slope near 1 proves competition.” It does not. Kenakin notes that a slope of unity can still give an erroneous KB, so check the parallel shift and the unchanged maximum as well.
  • “A slope below 1 means the drug is not competitive.” Kenakin says the cause may be non-competitive antagonism, but it may equally be nonequilibrium conditions in the procedure. Rule out the experimental cause before changing the pharmacological conclusion.
  • “Uptake does not matter.” Kenakin discusses agonist uptake mechanisms, described by the Furchgott model, as a reason for underestimating antagonist potency. The Studocu result for this query is titled for exactly this issue: re-uptake and Schild plots.
  • “pA2 is the same as KB.” It is an empirical estimate of it, valid under the competitive model.
  • “pA2 is a single number.” Report it with its confidence interval, as the CGRP study did.
  • “The Hill equation replaces Schild analysis.” They answer different questions: the Hill relation describes occupancy and concentration-response shape, while Schild analysis uses shifts between curves to test competition.

Where it matters in the lab

Schild analysis is used wherever an antagonist needs a defensible affinity estimate from functional data: receptor classification (Kenakin’s purpose), comparing tissues, and characterising peptide or small-molecule antagonists as in the CGRP study. The practical consequences for assay design follow from the sources. Use paired control and treated preparations so the dose ratios are comparable; allow the system to reach equilibrium; check the agonist curves overlay in shape before regressing; and report the slope test and pA2 interval together. The table of validity checks below, compiled from Kenakin’s review, is a checklist for the analysis stage. Related assay topics on this site include cAMP assays and allosteric modulators, where a competitive model may not describe the data.

Frequently asked questions

What is PA2 value in pharmacology?

It is the negative logarithm of the antagonist concentration that produces a twofold shift in the agonist EC50, so a higher pA2 means a more potent antagonist. When the competitive model holds with a slope of 1, it equals −log KB.

Can you give me an example of a competitive antagonist?

hαCGRP8-37 against αCGRP in a 2026 artery study: progressive rightward shifts, unchanged maximal relaxation, a Schild slope of 0.85 not different from 1 and a pA2 of 7.80. Competitive behaviour must still be confirmed in each preparation.

How to interpret a Schild plot?

Check that the underlying curves shift in parallel without a change in maximum, then read the slope of the log(DR − 1) versus log[B] line. A slope of 1 is consistent with simple competitive antagonism and the intercept gives pA2. A slope different from 1 may signal non-competitive antagonism or non-equilibrium conditions.

What is the Hill equation used for in pharmacology?

It describes the hyperbolic relation between concentration and fractional occupancy (or response), which underlies EC50 and IC50 estimation and Schild plots. The Hill coefficient is a separate topic, covered in our Hill coefficient guide.

Sources

  • Arunlakshana O, Schild HO. Some quantitative uses of drug antagonists. Br J Pharmacol Chemother 1959;14(1):48-58. doi:10.1111/j.1476-5381.1959.tb00928.x (Wiley, British Pharmacological Society). PubMed 13651579, read 2026-11-21.
  • Kenakin TP. The Schild regression in the process of receptor classification. Can J Physiol Pharmacol 1982;60(3):249-65. doi:10.1139/y82-036 (Canadian Science Publishing). PubMed 7042056, read 2026-11-21.
  • Jensen MN et al. Functional characterisation of dura mater αCGRP degradation fragments. J Headache Pain 2026. PMC13196087, read 2026-11-21.
  • Raffa RB et al. Two Routes to the Same Equation. Cureus 2026. PMC13380234, read 2026-11-21.
  • Neubig RR et al. IUPHAR NC-IUPHAR XXXVIII: update on terms and symbols in quantitative pharmacology. Pharmacol Rev 2003;55(4):597-606. PubMed 14657418 (terminology reference).

Data: Validity checks for a Schild regression and what each outcome implies

Checklist compiled from the abstract of Kenakin's 1982 review of the Schild regression: the conditions a competitive antagonist must meet, how slope outcomes are read, and known distortions.

Period covered: 1982.

Validity checks for a Schild regression and what each outcome implies
Observation or conditionInterpretationConsequence or note
Parallel displacement of agonist concentration-response curvesRequired of a competitive antagonistNon-parallel shifts: the Schild line does not support a competitive reading
No change in maximal responseRequired of a competitive antagonistA depressed maximum points away from simple competition
Dose ratios independent of agonist concentrationRequired: dose ratios must be unambiguousAmbiguous dose ratios make the regression unreliable
Linear regression slope of 1Consistent with simple competitive antagonismIntercept (empirical pA2) estimates KB
Slope significantly different from 1May mean non-competitive antagonism or non-equilibrium conditionsRule out the experimental cause first
Slope of 1 obtainedNecessary, not sufficientCan still give an erroneous KB
Agonist uptake mechanisms (Furchgott model)Can distort the apparent resultUnderestimates antagonist potency

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Schild Analysis: How to Build a Schild Plot and Read pA2 and Slope

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →