Written and maintained by CASRAI Editorial Board
Published
On this page
SimVascular is open-source software that takes medical image data of blood vessels and carries it through segmentation, solid modeling and meshing to patient-specific blood flow simulation and analysis, all in one package. It was created for cardiovascular research and has been used in studies of surgical planning and medical device design, and it is also taught in bioengineering courses.
Definition and scope
The SimVascular project home page describes the software as “a complete pipeline from medical image data segmentation to patient specific blood flow simulation and analysis”. The 2017 paper that introduced the fully open-source release states the same scope and calls the package a research tool for cardiovascular modeling and simulation. A second paper, published in the Journal of Biomechanical Engineering in 2018, describes it as covering image segmentation, three-dimensional solid modeling and mesh generation through to patient-specific simulation, and notes use in both research and education.
The reason a single package matters is stated in the 2017 paper. Most image-processing programs are not designed to produce models that are suitable for simulation, and most computational fluid dynamics (CFD) packages are not designed for the boundary conditions, physiological models and physics that cardiovascular work needs. SimVascular was built to join those two halves.
History in brief
According to the 2017 paper, the package was originally developed in the laboratory of Charles Taylor at Stanford University and released in 2007. It then depended on several licensed components, which the authors say hindered adoption by new users and prevented a complete open-source release. A revitalization project launched in 2013 set out to replace those components with open-source alternatives and to add infrastructure: case studies, online documentation, CMake compatibility, a user forum and binary packages for the major operating systems.
This page describes the software as the project and its papers describe it. It does not describe a medical service, and nothing here is clinical advice. The 2017 paper itself separates the research package from the clinical simulation-based service that HeartFlow introduced as the first of its kind to be FDA approved.
How SimVascular is used in practice
The 2017 paper lays out the working order of the pipeline. Each stage feeds the next, and the model faces named at the modeling stage are the handles used later to assign boundary conditions.
1. Image data and paths
The input is image data from a scan, typically angiographic CT or MRI. The paper notes that the segmentation process usually starts by creating pathlines along the vessels of interest. For the lofted 2D method, the pathlines are used to resample the image into a cross-sectional window that can be moved along the vessel.
2. Segmentation
Two families of method are described. Lofted 2D segmentation moves along each pathline and delineates the lumen boundary in each cross-section, using level set, threshold, manual or analytic (circle or ellipse) segmentation. The paper says manual segmentation is useful for noisy data sets or cases where the automated methods fail to converge, and that a “batch mode” can generate segmentations automatically along a range of the path, which are then checked and edited. Direct 3D segmentation places seed spheres that expand and merge to fill the lumen; the paper identifies it as useful for aneurysms and vessel junctions, which do not suit 2D cross-sections. The project home page also lists automatic segmentation using machine learning.
3. Solid model
Segmentations are lofted into a solid model, and branches are combined with Boolean operations. The paper lists four solid modeling approaches: PolyData, OpenCASCADE, Parasolid and Discrete. Faces of the model receive names and identifiers (ModelFaceID), which later specify boundary conditions and material properties. A discrete model made in another segmentation program, for example an STL file, can be imported as a PolyData model.
4. Mesh
Meshing produces an unstructured tetrahedral volume mesh. The paper describes boundary layer meshing, which uses thinner elements near the wall where the velocity gradient normal to the surface changes most, as well as radius-based meshing, regional refinement and adaptive meshing driven by error estimates. The project home page lists boundary layer and local refinement among the meshing options.
5. Simulation and post-processing
The 2017 paper describes a presolver, a flow solver and a postsolver. It notes that the solver can be run from the graphical interface, but that it is common to prepare simulation files on a desktop computer and copy them to a high performance computing (HPC) cluster to run in parallel. The same paper describes inlet and outlet conditions that can be prescribed directly or derived from reduced-order models of the vasculature upstream and downstream, in an open-loop or closed-loop manner. Closed-loop coupling is described as potentially necessary in surgical planning applications, where a virtual change to the geometry may alter inflow compared with the nominal or measured values.
Scripting
The package includes a console in which C++ functions bound by Tcl or Python can be called, so users can run custom scripts in addition to or instead of the graphical interface. The paper says this lets users automate repeatable procedures. The current documentation lists a Python interface as its own section.
Solver types and model fidelity
The project home page lists three solvers, and the documentation covers them under separate headings. The data table below sets them beside the solid modeling and meshing components, with the licensing statements as the sources give them.
- svMultiPhysics is described as a parallel multi-physics finite element solver, including arbitrary Lagrangian-Eulerian fluid-structure interaction (FSI). The documentation names it for 3D multiphysics, CFD and 0D/1D reduced-order simulation.
- svOneDSolver is described as a reduced-order solver for the hemodynamics in deformable 1D vascular networks.
- svZeroDSolver is described as a reduced-order, lumped parameter solver.
The sources do not rank these by accuracy, and this page does not either. They describe different representations of the vasculature: a full 3D domain, a 1D network, or a lumped 0D model. Which one answers a given research question is a modeling decision for the investigator, and the 2017 paper describes reduced-order models as one way to supply boundary conditions to a 3D model.
Where it matters for labs and research offices
Licensing and software inventory
The home page states that SimVascular components are BSD licensed, lists Tetgen as AGPL-3.0, and lists MeshSim as commercial software to be obtained from Simmetrix. The 2017 paper treats MeshSim and Parasolid as optional licensed components, alongside the TetGen-based mesher and the OpenCASCADE kernel. A lab that records its software dependencies for a data management plan or a methods section can use this to note which meshing and solid modeling kernel a study actually used, since the choice changes the licensing position of the workflow.
Reproducibility and documentation
Three features in the sources support documenting a computation. The scripting console can automate repeatable procedures. The documentation provides clinical example cases (Coronary Normal, Aortofemoral Normal 1 and 2, Healthy Pulmonary) and the project links example projects hosted on SimTK. The 2017 paper demonstrates the software on publicly available sample case studies. Re-running a published example is a way to confirm that an installation behaves as the documentation describes before applying it to new data. The home page gives no version number or operating system list, so that information has to be taken from the release you download.
Teaching
The 2018 paper reports classroom use in bioengineering education and describes a GATEWAY web portal created to make educational access easier. The home page links a Supercomputing Gateway for running simulations.
Extending the pipeline
Published extensions show how groups build on it. A 2021 paper in BMC Research Notes developed a pipeline that writes boundary condition files for SimVascular CFD simulations to include the effect of an inlet catheter. The authors report that because the method manipulates the inlet boundary condition it is sensitive to mesh density: the finer the mesh, especially around the catheter wall, the more accurate the velocity estimates. That is a concrete example of a result that depends on a meshing choice, which a methods section should therefore report.
How to cite
The two software papers carry the citations: Updegrove et al., “SimVascular: An Open Source Pipeline for Cardiovascular Simulation”, Annals of Biomedical Engineering 2017;45(3):525-541, doi:10.1007/s10439-016-1762-8; and Lan et al., “A Re-Engineered Software Interface and Workflow for the Open-Source SimVascular Cardiovascular Modeling Package”, Journal of Biomechanical Engineering 2018;140(2):024501, doi:10.1115/1.4038751. The project also links its source code on GitHub and its downloads on SimTK.
Related modeling tools on CASRAI
SimVascular sits in the family of computational biomedical tools that lab groups use to turn imaging or measurements into simulations. For musculoskeletal modeling, see the guide to OpenSim. For a systems-biology environment, see SimBiology. The broader context is in the guides to biomedical engineering and biomechanics, and the wider modeling context is covered under digital twins in healthcare.
Common misunderstandings
“Fully open source” does not mean every option is open
The 2017 paper says the commercial components were replaced to create a fully open-source pipeline, yet the same paper describes Parasolid and MeshSim as optional licensed components, and the home page lists MeshSim as commercial. The licensed options are additions to the open-source components, not requirements of the pipeline as the paper describes it.
It is not a clinical product
The papers describe SimVascular as a research tool and as software for education. The 2017 paper contrasts it with a separate FDA-approved clinical service. Nothing in the sources states a regulatory status for SimVascular itself, and this page makes no such claim.
It is not a single button
Every stage above involves choices: the segmentation method, the solid modeling kernel, the mesh, and the boundary conditions. The papers say boundary conditions are essential to obtaining valid, physiologically realistic results, and the catheter study shows results shifting with mesh density.
One solver does not cover every question
The project provides 3D, 1D and 0D solvers because the model scale differs. Choosing among them is part of the study design and should be stated in the methods.
Sources
- SimVascular project home page, read 17 November 2026.
- SimVascular documentation index, read 17 November 2026.
- Updegrove A, Wilson NM, Merkow J, Lan H, Marsden AL, Shadden SC. SimVascular: An Open Source Pipeline for Cardiovascular Simulation. Ann Biomed Eng 2017. doi:10.1007/s10439-016-1762-8; full text PMC6546171, read 17 November 2026.
- Lan H, Updegrove A, Wilson NM, Maher GD, Shadden SC, Marsden AL. A Re-Engineered Software Interface and Workflow for the Open-Source SimVascular Cardiovascular Modeling Package. J Biomech Eng 2018. doi:10.1115/1.4038751, read 17 November 2026.
- Taebi A, Berk S, Roncali E. Realistic boundary conditions in SimVascular through inlet catheter modeling. BMC Res Notes 2021. doi:10.1186/s13104-021-05631-7, read 17 November 2026.
Data: SimVascular pipeline components: stage, role and licensing as stated by the project and its papers
Compiled from the SimVascular project home page and the 2017 Annals of Biomedical Engineering paper. Lists solid modeling, meshing and solver components with their pipeline stage, described role and the licensing wording each source gives.
| Component | Pipeline stage | Role as described | Licensing as stated |
|---|---|---|---|
| PolyData | Solid modeling | Custom procedures combined with VTK and VMTK filters; produces an unstructured triangulated surface | No licence stated in the paper |
| OpenCASCADE | Solid modeling | CAD kernel that lofts 2D segmentations into a NURBS surface; also used in FreeCAD | No licence stated in the paper |
| Parasolid | Solid modeling | NURBS lofting and CAD procedures; also used in SolidWorks | Optional licensed plugin |
| Discrete | Solid modeling | Represents a discrete PolyData surface as a model usable by MeshSim | Optional plugin |
| TetGen-based mesher | Meshing | TetGen plus custom adaptive meshing, VMTK boundary layer and radius-based meshing, and MMG surface remeshing | Open-source kernel; home page lists Tetgen as AGPL-3.0 |
| MeshSim | Meshing | Mesher by Simmetrix with similar range of options to the TetGen kernel | Optional licensed mesher; commercial per home page |
| svMultiPhysics | Simulation | Parallel multi-physics finite element solver including ALE-based fluid-structure interaction | SimVascular components BSD per home page |
| svOneDSolver | Simulation | Reduced-order solver for hemodynamics in deformable 1D vascular networks | SimVascular components BSD per home page |
| svZeroDSolver | Simulation | Reduced-order, lumped parameter solver | SimVascular components BSD per home page |
Sources
- SimVascular project home page (accessed 2026-11-17)
- Updegrove et al. 2017, SimVascular: An Open Source Pipeline for Cardiovascular Simulation (PMC6546171) (accessed 2026-11-17)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.