Written and maintained by CASRAI Editorial Board
Published
On this page
The Society for Implementation Research Collaboration (SIRC) is an international professional society dedicated to closing the gap between research discovery and routine healthcare delivery through rigorous implementation science methodology. SIRC provides standardized frameworks, collaborative research networks, and open-access measurement resources—most notably the Instrument Review Project (IRP) and the Psychometric and Pragmatic Evidence Rating Scale (PAPERS)—that enable researchers, laboratories, and health systems to evaluate how evidence-based practices, clinical protocols, and diagnostic workflows are adopted, executed, and sustained in real-world settings.
Definition and scope of SIRC in implementation science
Implementation science investigates the methods and strategies that facilitate the systematic uptake of evidence-based research findings into routine healthcare, laboratory operations, and public health practice. Across translational medicine, clinical discoveries historically suffer from an estimated 17-year research-to-practice lag, during which proven interventions fail to reach routine service delivery or are implemented inconsistently. SIRC was established to bridge this divide by creating methodological infrastructure, building research-practice partnerships, and standardizing measurement across the discipline.
The organization originated in 2010 as the Seattle Implementation Research Conference, supported by a National Institute of Mental Health (NIMH) R13 conference grant awarded to founding president Dr. Kate Comtois. Conceived initially to convene behavioral health investigators and clinical stakeholders, the conference expanded rapidly. In response to interdisciplinary demand, the initiative transitioned from a regional meeting series into an independent, non-profit international professional society. Today, SIRC spans multiple health disciplines, connecting academic investigators, implementation specialists, clinical laboratory directors, and healthcare administrators.
Within academic governance and professional development, SIRC operates four core collaborative networks: the Established Investigator Network (EIN), the New Investigator Network (NIN), the Practitioner-Researcher Collaborative (PRC), and the Student/Trainee Network. These networks support mentorship, peer review of implementation protocols, and multi-site research partnerships. In addition to hosting biennial international conferences featuring empirical implementation research, SIRC established Implementation Research and Practice, a peer-reviewed, open-access journal published in partnership with SAGE Publications. The journal provides a dedicated platform for studies evaluating implementation strategies, pragmatic measurement development, and real-world protocol integration across community, health system, and public health research initiatives.
How SIRC and the Instrument Review Project operate in practice
Historically, one of the most persistent methodological barriers in implementation science was known as the ‘measurement problem.’ Investigators and healthcare systems frequently developed idiosyncratic, unvalidated surveys to evaluate implementation progress. In early systematic assessments, fewer than 10 percent of published implementation studies utilized quantitative tools with demonstrated psychometric reliability and construct validity. To establish methodological rigor, SIRC initiated the Instrument Review Project (IRP), funded by the National Institute of Mental Health through grant R01MH106510 under Principal Investigator Dr. Cara C. Lewis.
The Instrument Review Project established a standardized seven-stage enhanced systematic review methodology designed to identify, categorize, and evaluate every quantitative measure available in implementation literature. The project operationalized the review process through the following structured sequence:
- Stage 1: Setting the Review Scope: Defining search parameters focused on quantitative surveys and structured observational tools applied in behavioral health, medical care, school settings, and public health programs.
- Stage 2: Identifying Conceptual Frameworks: Grounding the taxonomy of constructs in leading dissemination and implementation models. SIRC mapped instruments directly against the Consolidated Framework for Implementation Research (CFIR) to capture contextual determinants and Proctor et al.’s implementation outcomes framework. Investigators evaluating multi-level determinants often consult an implementation science framework selection guide to align their organizational context with appropriate measurement tiers.
- Stage 3: Generating Standardized Search Protocols: Constructing systematic bibliographic queries combining implementation terminology with specific construct labels to exhaustively index peer-reviewed literature.
- Stage 4: Literature Review of Identified Instruments: Screening publications to isolate individual measurement instruments, extracting their item sets, administrative guidelines, and validation histories.
- Stage 5: Developing Evidence-Based Assessment Criteria: Formulating objective evaluation standards that grade both the traditional psychometric strength of the instrument and its practical utility in real-world practice settings.
- Stage 6: Data Extraction and Task Force Rating: Mobilizing an international task force of implementation researchers and methodology experts to independently review validation evidence and assign consensus quality ratings.
- Stage 7: Centralized Open-Access Repository: Publishing the synthesized ratings, instrument files, and comparative evaluation matrices in a web-based repository accessible to investigators and practitioners worldwide.
Through this seven-stage protocol, SIRC synthesized data from hundreds of individual measurement scales. The resulting open repository allows health system leaders and research teams to compare instruments head-to-head, eliminating the need to create redundant, unvalidated survey tools for new project rollouts.
The PAPERS framework: evaluating psychometric and pragmatic properties
A central breakthrough produced by the SIRC Instrument Review Project was the development of the Psychometric and Pragmatic Evidence Rating Scale (PAPERS), documented by Stanick et al. in 2021. Prior to PAPERS, measurement evaluation relied almost exclusively on classical psychometric frameworks such as the COSMIN checklist. While psychometric criteria evaluate whether a scale measures a latent construct accurately, they fail to consider whether the tool is feasible for routine use in high-volume clinics, diagnostic laboratories, or community health environments. A 50-item questionnaire with outstanding construct validity is practically useless if busy clinical technicians or laboratory analysts refuse to complete it due to time constraints.
The PAPERS framework resolves this dilemma by pairing formal psychometric evaluation with stakeholder-driven pragmatic criteria. The evaluation system scores each property on a standardized six-point rating scale: -1 indicates poor evidence or psychometric flaws; 0 indicates no published evidence; 1 represents minimal or emerging evidence; 2 denotes adequate evidence; 3 reflects good evidence; and 4 represents excellent empirical validation.
Under PAPERS, psychometric criteria examine the scientific rigor of the tool across several key dimensions:
- Internal Consistency: Verifies the degree to which items within a subscale correlate with one another, typically established through a Cronbach’s alpha or composite reliability coefficient between 0.70 and 0.90.
- Convergent Validity: Tests whether the measure correlates positively with existing instruments that evaluate identical or conceptually adjacent constructs.
- Discriminant Validity: Confirms that the measure demonstrates weak or non-significant correlations with unrelated constructs, ensuring distinct measurement boundaries.
- Structural Validity: Assesses the underlying factor structure of the tool using exploratory and confirmatory factor analysis (CFA) to verify that item loadings match theoretical dimensions.
- Predictive Validity: Evaluates whether baseline scores on the instrument reliably forecast downstream implementation success, such as sustained protocol adherence or clinical adoption rates.
- Responsiveness and Norms: Assesses the instrument’s capacity to detect meaningful change over time in response to implementation strategies, alongside the availability of established reference benchmarks.
Concurrently, PAPERS evaluates pragmatic dimensions identified by frontline clinicians, healthcare administrators, and public health managers during Delphi consensus panels:
- Cost and Licensing: Instruments receive high pragmatic ratings if they are in the public domain and available without licensing fees, user registration gates, or proprietary software requirements.
- Brevity: Tools must minimize administrative burden. Instruments with 10 or fewer items that require under 5 minutes to complete receive top ratings, whereas instruments exceeding 30 items receive poor pragmatic marks.
- Readability: Assessed via standardized linguistic metrics such as the Flesch-Kincaid reading grade level. Measures intended for frontline staff or patient respondents should not exceed an 8th-grade reading level.
- Training Burden: The instrument must be self-explanatory, requiring no formal training certification, workshop attendance, or specialized psychometric expertise to administer.
- Interpretation and Scoring Simplicity: The scoring rubric must rely on straightforward summation or averaging, with clear cutoff values that do not require complex statistical transformations or proprietary algorithms.
- Actionability: Scores must generate direct operational insights that inform immediate decision-making, such as identifying specific workflow bottlenecks or signalling when an implementation strategy requires modification.
Sourced comparison: psychometric vs. pragmatic evaluation criteria
The following table illustrates how the PAPERS framework contrasts classical psychometric properties against stakeholder-derived pragmatic criteria when reviewing implementation instruments:
| Evaluation Dimension | Focus Domain | Primary Metric or Standard | Threshold for Top Rating (Score 4) | Published Evidence Source |
|---|---|---|---|---|
| Internal Consistency | Psychometric Rigor | Cronbach’s alpha / Raykov’s rho | Alpha between 0.80 and 0.90 in target sample | Stanick et al. (2021) |
| Structural Validity | Psychometric Rigor | Confirmatory Factor Analysis (CFA) fit indices | CFI >= 0.95, TLI >= 0.95, RMSEA <= 0.06 | Lewis et al. (2015) |
| Predictive Validity | Psychometric Rigor | Longitudinal regression / odds ratios | Statistically significant prediction of implementation outcome | Stanick et al. (2021) |
| Cost and Availability | Pragmatic Utility | Licensing fees and access restrictions | Public domain, free access without proprietary gating | Stanick et al. (2021) |
| Instrument Brevity | Pragmatic Utility | Item count and completion duration | 10 or fewer items; completion under 5 minutes | Stanick et al. (2021) |
| Readability Level | Pragmatic Utility | Flesch-Kincaid Reading Grade Level formula | Eighth-grade reading level or lower (grade <= 8.0) | Stanick et al. (2021) |
| Scoring and Interpretation | Pragmatic Utility | Computational complexity of scoring rubric | Direct item averaging or simple sum without specialized software | Stanick et al. (2021) |
Core validated implementation outcome measures: AIM, IAM, and FIM
Among the most widely adopted measurement innovations developed by SIRC investigators is the suite of three pragmatic implementation outcome instruments validated by Weiner et al. in 2017: the Acceptability of Intervention Measure (AIM), the Intervention Appropriateness Measure (IAM), and the Feasibility of Intervention Measure (FIM). Prior to this work, researchers often conflated these three constructs, treating acceptability, appropriateness, and feasibility as interchangeable indicators of general satisfaction.
Drawing upon Proctor et al.’s conceptual model, Weiner and colleagues established distinct theoretical boundaries for each construct:
- Acceptability (AIM): The perception among implementation stakeholders that a given service, clinical innovation, or diagnostic protocol is agreeable, palatable, or satisfactory.
- Appropriateness (IAM): The perceived fit, relevance, or compatibility of the innovation for a given practice setting, patient population, or provider scope of practice.
- Feasibility (FIM): The extent to which a new clinical practice, laboratory workflow, or evidence-based guideline can be successfully used or carried out within a specific operational setting.
Each of the three instruments consists of exactly four items scored on a standard 5-point Likert scale (1 = Completely disagree, 2 = Disagree, 3 = Neither agree nor disagree, 4 = Agree, 5 = Completely agree). Psychometric testing across rigorous confirmatory factor analyses demonstrated outstanding structural validity, with clean three-factor separation and high internal consistency (Cronbach’s alpha of 0.89 for AIM, 0.88 for IAM, and 0.88 for FIM). Because each scale takes less than one minute to complete, all three measures can be administered simultaneously in under three minutes, achieving an exceptional pragmatic rating under the PAPERS framework.
The operational value of distinguishing these three constructs is profound. For instance, in an organizational change initiative analyzed under diffusion of innovations theory, clinicians may report high acceptability (they believe the new diagnostic platform is clinically valuable) while simultaneously reporting poor feasibility (they lack staff coverage or laboratory space to run the equipment). Disaggregating these dimensions allows implementation leaders to deploy targeted strategies—such as workflow restructuring rather than additional persuasive education.
Step-by-step walkthrough: implementing AIM, IAM, and FIM in a laboratory setting
To illustrate how research offices and laboratory managers operationalize SIRC measurement tools, consider a regional public health diagnostic laboratory transitioning from conventional culture-based bacteriology to an automated multiplex molecular diagnostic assay. The implementation team utilizes AIM, IAM, and FIM to guide the rollout across four operational stages:
- Pre-Implementation Baseline Assessment: Prior to equipment installation, laboratory bench technologists and supervisory pathologists complete the 12 items of the AIM, IAM, and FIM via a digital survey. The team computes mean subscale scores. Baseline results indicate high acceptability (mean AIM = 4.6/5.0) and high appropriateness (mean IAM = 4.4/5.0), but borderline feasibility (mean FIM = 2.8/5.0). Qualitative follow-up reveals that laboratory staff are concerned about calibration schedules and electronic laboratory information system (LIMS) interfacing.
- Targeted Implementation Strategy Deployment: Because the feasibility deficit is precisely isolated, management avoids wasting resources on generic promotional seminars. Instead, the lab deploys targeted technical implementation strategies: automated bi-directional LIMS middleware integration and hands-on instrument calibration workshops conducted by vendor technical specialists.
- Mid-Implementation Monitoring (Pilot Phase): Three months into the pilot testing phase, the survey is re-administered. Mean feasibility increases significantly to 4.2/5.0, while acceptability and appropriateness remain stable above 4.5/5.0. This quantitative shift demonstrates that the technical workflows have successfully resolved frontline barriers.
- Sustained Quality Audit: Twelve months post-implementation, the laboratory incorporates the brief FIM tool into its annual quality management review, confirming that ongoing reagent replenishment and staffing turnover have not degraded operational feasibility.
By applying brief, psychometrically sound instruments, the laboratory avoids anecdotal guesswork, tracking implementation progress with quantitative rigor identical to clinical diagnostic validation.
Where SIRC methodology matters for public health, laboratories, and clinical practice
While SIRC originated within mental and behavioral health disciplines, its methodologies and measurement standards are now deeply embedded across biomedical research administration, clinical diagnostic laboratories, and public health systems. In modern grant applications—particularly those submitted to the National Institutes of Health (NIH), the Centers for Disease Control and Prevention (CDC), and the Agency for Healthcare Research and Quality (AHRQ)—reviewers actively look for validated implementation frameworks and pragmatic measurement protocols. Submitting proposals that rely on ad-hoc surveys rather than SIRC-evaluated instruments frequently results in poor methodological scoring.
In clinical laboratories and biomedical research facilities, implementation science methodology is vital during the introduction of new diagnostic technologies, automated robotics, and safety protocols. Implementing an advanced assay requires far more than verifying analytical sensitivity and specificity; it requires institutional adoption, laboratory staff adherence, and sustained workflow integration. SIRC’s focus on measuring implementation climate, leadership, and operational readiness (using validated tools such as the Implementation Climate Scale and the Organizational Readiness for Implementing Change survey) provides laboratory directors with actionable diagnostics to prevent costly instrumentation abandonments.
Furthermore, within public health policy and disease surveillance, SIRC methodologies support evidence synthesis. When public health agencies evaluate broad health interventions across diverse community clinics, implementation researchers conduct systematic reviews and meta-analyses to compare intervention fidelity and outcomes across sites. In synthesizing evidence, methodological rigor requires distinguishing between observational implementation metrics and pooled statistical effect sizes, as highlighted in standard comparisons of systematic review versus meta-analysis methodology. The standardized ratings provided by SIRC allow systematic reviewers to assess risk of measurement bias across published implementation trials.
The data table below compares validated implementation outcome and organizational determinant measures evaluated in SIRC initiatives, documenting their target constructs, item counts, administration times, and psychometric reliability.
Common misunderstandings about SIRC and implementation measurement
Several persistent misunderstandings surround the Society for Implementation Research Collaboration and the broader practice of implementation measurement:
- Confusion with Unrelated Acronyms: Because ‘SIRC’ is an unreserved acronym, it is frequently confused with external entities such as the Security Intelligence Review Committee (the former Canadian national intelligence oversight body), the Social Issues Research Centre (a UK social research non-profit), or publicly traded commercial corporations. Within health services, biomedical research, and public health administration, SIRC specifically denotes the Society for Implementation Research Collaboration.
- Equating Implementation Measures with Clinical Outcome Metrics: A frequent conceptual error involves confusing implementation outcomes (such as acceptability, feasibility, and adoption) with client or patient clinical outcomes (such as symptom reduction, viral load suppression, or biomarker changes). Implementation measures assess the delivery vehicle and operational processes of an intervention, whereas clinical metrics assess biological or therapeutic response. Both are essential, but one cannot substitute for the other.
- Assuming Longer Surveys Provide Superior Measurement: In classical psychometrics, longer instruments with 30 to 60 items often yield slightly higher internal consistency coefficients. However, in routine health services and clinical laboratories, respondent fatigue and survey abandonment severely distort data collection. SIRC’s empirical validation of 4-item scales (such as AIM, IAM, and FIM) proves that brief, pragmatic measures can achieve structural validity and reliability comparable to lengthy psychological batteries while preserving frontline response rates.
- Believing Implementation Science Only Applies to Community Psychotherapy: While early implementation research heavily emphasized mental health counseling, modern implementation frameworks and SIRC instruments apply universally across clinical pathology, molecular diagnostics, surgical safety checklists, hospital infection control, and pharmaceutical stewardship programs. Any protocol that requires consistent human adherence within an organization benefits from SIRC measurement models.
- Treating Implementation as a Single Pre-Launch Event: Implementation is not a static checklist that concludes once equipment is purchased or staff attend an orientation. Longitudinal SIRC studies demonstrate that implementation determinants evolve across pre-implementation, active adoption, integration, and long-term sustainment phases, requiring repeated measurement at defined operational intervals.
Frequently asked questions
What is the primary mission of the Society for Implementation Research Collaboration?
SIRC is an international professional organization dedicated to bridging the research-to-practice gap in healthcare and public health. It facilitates collaboration between academic researchers, clinical practitioners, and community leaders, promoting rigorous methodology, validated measurement tools, and evidence-based practice implementation.
What is the SIRC Instrument Review Project?
The SIRC Instrument Review Project (IRP) was an NIMH-funded initiative (grant R01MH106510) that systematically identified, categorized, and evaluated quantitative measurement instruments used in implementation research. The project established standardized psychometric and pragmatic assessment criteria, cataloging hundreds of tools in an open-access repository.
How does the PAPERS framework evaluate implementation measures?
The Psychometric and Pragmatic Evidence Rating Scale (PAPERS) evaluates implementation measures across two complementary domains. It scores psychometric rigor (internal consistency, structural validity, predictive validity, and convergent validity) alongside real-world pragmatic utility (cost, brevity, readability, training burden, and scoring ease) on a standardized rating scale from -1 to 4.
What are the AIM, IAM, and FIM measures developed by SIRC investigators?
The Acceptability of Intervention Measure (AIM), Intervention Appropriateness Measure (IAM), and Feasibility of Intervention Measure (FIM) are three 4-item pragmatic surveys developed by Weiner, Lewis, and colleagues. They provide brief, psychometrically validated assessments of key implementation outcomes, taking under two minutes to administer.
How does SIRC methodology support clinical and diagnostic laboratories?
SIRC methodologies help laboratory managers and pathologists track how new diagnostic workflows, molecular assays, and automated systems are adopted by technical staff. By measuring implementation climate, leadership, and operational feasibility, laboratories can diagnose workflow bottlenecks and ensure sustained protocol adherence.
Where can researchers access SIRC instruments and publication resources?
Researchers can access synthesized instrument ratings, survey items, and scoring manuals through the official SIRC Instrument Project repository at societyforimplementationresearchcollaboration.org. In addition, empirical implementation studies and measurement advances are published in SIRC’s official open-access journal, Implementation Research and Practice.
Sources
- Lewis CC, Stanick CF, Martinez RG, Weiner BJ, Kim M, Barwick M, Phillips KE, Nguyen AM, Hanley S, Melvin A. The Society for Implementation Research Collaboration Instrument Review Project: a methodology to promote rigorous evaluation. Implementation Science. 2015;10:2. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4308900/ (Accessed 2026-11-14).
- Stanick CF, Halko HM, Nolen EA, Powell BJ, Dorsey CN, Mettert KD, Weiner BJ, Barwick M, Wolfenden L, Damschroder LJ, Lewis CC. Pragmatic measures for implementation research: development of the Psychometric and Pragmatic Evidence Rating Scale (PAPERS). Translational Behavioral Medicine. 2021;11(1):11–20. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7877299/ (Accessed 2026-11-14).
- Weiner BJ, Lewis CC, Stanick C, Powell BJ, Dorsey CN, Clary AS, Boynton MH, Halko H. Psychometric assessment of three newly developed implementation outcome measures. Implementation Science. 2017;12:108. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5576104/ (Accessed 2026-11-14).
- Lewis CC, Boyd MR, Walsh-Bailey C, Lyon AR, Beidas R, Mittman B, Weiner B, Saldana L, Powell BJ. Outcomes for implementation research: conceptual and methodological considerations. Implementation Research and Practice. 2020;1:1–12. Available from: https://journals.sagepub.com/doi/10.1177/2633489520970334 (Accessed 2026-11-14).
- Society for Implementation Research Collaboration (SIRC). About SIRC and Biennial Conference Overview. Available from: https://societyforimplementationresearchcollaboration.org/ (Accessed 2026-11-14).
- Society for Implementation Research Collaboration (SIRC). SIRC Instrument Review Project Repository. Available from: https://societyforimplementationresearchcollaboration.org/sirc-instrument-project/ (Accessed 2026-11-14).
Data: Implementation Outcome and Determinant Measures Evaluated in SIRC Initiatives
Original compilation comparing validated quantitative implementation measures reviewed in SIRC projects, detailing construct, item counts, administration time, target respondent, and psychometric reliability across peer-reviewed publications.
Period covered: 2015/2026. Coverage: Global.
| Measure Name | Construct Measured | Item Count (items) | Completion Time (minutes) | Target Respondent | Reliability (Cronbach Alpha) |
|---|---|---|---|---|---|
| Acceptability of Intervention Measure (AIM) | Acceptability | 4 | 2 | Clinical providers and staff | 0.89 |
| Intervention Appropriateness Measure (IAM) | Appropriateness | 4 | 2 | Clinical providers and staff | 0.88 |
| Feasibility of Intervention Measure (FIM) | Feasibility | 4 | 2 | Clinical providers and staff | 0.88 |
| Organizational Readiness for Implementing Change (ORIC) | Readiness for Change | 12 | 5 | Organizational leaders and staff | 0.88-0.92 |
| Evidence-Based Practice Attitude Scale (EBPAS-15) | Provider Attitudes toward EBPs | 15 | 6 | Healthcare and behavioral providers | 0.76-0.79 |
| Implementation Climate Scale (ICS) | Implementation Climate | 18 | 7 | Workgroup clinicians and supervisors | 0.81-0.91 |
| Implementation Leadership Scale (ILS) | Implementation Leadership | 12 | 5 | First-level supervisors and team leads | 0.95-0.98 |
Sources
- Psychometric assessment of three newly developed implementation outcome measures (accessed 2026-11-14)
- The Society for Implementation Research Collaboration Instrument Review Project (accessed 2026-11-14)
- Pragmatic measures for implementation research: development of the PAPERS scale (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.